Hui Meng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hui Meng has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Haoze Luo
Zhejiang University
2 shared publications - Zhen Xin
State Key Laboratory of Intelligent Power Distribution Equipment and System, Hebei University of Technology, Tianjin, China
2 shared publications - Ankang Zhu
College of Electrical Engineering, Zhejiang University, Hangzhou, China
1 shared publication - Chi Yung Chung
The Hong Kong Polytechnic University
1 shared publication - Fujun Zheng
College of Electrical Engineering, Zhejiang University, Hangzhou, China
1 shared publication - Jianlong Kang
State Key Laboratory of Intelligent Power Distribution Equipment and System, Hebei University of Technology, Tianjin, China
1 shared publication
Latest Publications
- 20 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 12015-12020
An Online Gate Oxide Degradation Monitoring Method for SiC MOSFETs Based on Turn-ON Gate Current Change Rate
Gate oxide degradation (GOD) presents a reliability issue for silicon carbide metal-oxide-semiconductor field-effect transistors, especially under high-temperature and high-electric-field conditions. This letter proposes an online condition monitoring method based on the peak value of the turn-on gate current change rate (dig/dt,max). The technique utilizes a noninvasive PCB Rogowski coil to measure dig/dt,max, demonstrating high practicality. Accelerated aging tests under positive and negative high-temperature gate bias and high-temperature gate switching conditions reveal correlations between dig/dt,max and GOD, with variations of 5.61%, 5% and 8.33%, after 160 h of aging. Double pulse test (DPT) results indicate that dig/dt,max is independent of external factors, such as temperature, drain-source voltage (Vds), drain current (Ids) and package aging. Results from a buck converter further validate the feasibility of long-term online monitoring.
- 20 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 12015-12020
An Online Gate Oxide Degradation Monitoring Method for SiC MOSFETs Based on Turn-ON Gate Current Change Rate
Gate oxide degradation (GOD) presents a reliability issue for silicon carbide metal-oxide-semiconductor field-effect transistors, especially under high-temperature and high-electric-field conditions. This letter proposes an online condition monitoring method based on the peak value of the turn-on gate current change rate (dig/dt,max). The technique utilizes a noninvasive PCB Rogowski coil to measure dig/dt,max, demonstrating high practicality. Accelerated aging tests under positive and negative high-temperature gate bias and high-temperature gate switching conditions reveal correlations between dig/dt,max and GOD, with variations of 5.61%, 5% and 8.33%, after 160 h of aging. Double pulse test (DPT) results indicate that dig/dt,max is independent of external factors, such as temperature, drain-source voltage (Vds), drain current (Ids) and package aging. Results from a buck converter further validate the feasibility of long-term online monitoring.
- Open Access
- 26 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 4, 561-566
A Highly Precise On-State Voltage Measurement Circuit With Dual Current Sources for Online Operation of SiC MOSFETs
This letter proposes an on-state drain-source voltage (Vds,on) measurement circuit for SiC MOSFETs. The proposed circuit effectively solves the problem of inconsistent diode volt-ampere characteristics through an additional current source. The voltage difference between the two diodes is compensated by adjusting the auxiliary current under the condition of a fixed first current. This circuit does not require diode pre-selection and significantly improves measurement accuracy. The circuit is implemented in a double-pulse test (DPT) of a SiC MOSFET (900 V/23 A, 25 °C). The results show that the circuit has a fast response speed with a delay time of 0.4μs. Even at the same current, the forward voltage difference between the two diodes reaches 3.32 mV. Compared to measurement results from a six-bit semi-digital multimeter, the measurement error of the proposed circuit is less than 1.5% at different currents and temperatures.
- 26 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 4, 561-566
Open AccessA Highly Precise On-State Voltage Measurement Circuit With Dual Current Sources for Online Operation of SiC MOSFETs
This letter proposes an on-state drain-source voltage (Vds,on) measurement circuit for SiC MOSFETs. The proposed circuit effectively solves the problem of inconsistent diode volt-ampere characteristics through an additional current source. The voltage difference between the two diodes is compensated by adjusting the auxiliary current under the condition of a fixed first current. This circuit does not require diode pre-selection and significantly improves measurement accuracy. The circuit is implemented in a double-pulse test (DPT) of a SiC MOSFET (900 V/23 A, 25 °C). The results show that the circuit has a fast response speed with a delay time of 0.4μs. Even at the same current, the forward voltage difference between the two diodes reaches 3.32 mV. Compared to measurement results from a six-bit semi-digital multimeter, the measurement error of the proposed circuit is less than 1.5% at different currents and temperatures.
- 22 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (9) , 10574-10578
Online Junction Temperature Extraction With Gate Voltage Under Nontrigger Current for High-Voltage Thyristor
This letter proposes a junction temperature ( $T_{j}$ ) extraction method for the high-voltage thyristors with the cathode short-circuiting structure. It has been studied that the gate voltage $V_{gk}$ under non-trigger current is a practical temperature-sensitive electrical parameter (TSEP), which can be used for online $T_{j}$ monitoring by calibrating the linear relationship between the gate voltage $V_{gk}$ under non-trigger current and $T_{j}$ effect. The proposed TSEP does not affect the operating state of the thyristor and is suitable for complex operating conditions since it is extracted during OFF state. The total error in the $T_{j}$ estimate obtained from the proposed TSEP is verified within ±2 °C by comparing with the $T_{j}$ obtained from the traditional gate voltage $V_{GK}$ based TSEP during ON state.
- 22 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (9) , 10574-10578
Online Junction Temperature Extraction With Gate Voltage Under Nontrigger Current for High-Voltage Thyristor
This letter proposes a junction temperature ( $T_{j}$ ) extraction method for the high-voltage thyristors with the cathode short-circuiting structure. It has been studied that the gate voltage $V_{gk}$ under non-trigger current is a practical temperature-sensitive electrical parameter (TSEP), which can be used for online $T_{j}$ monitoring by calibrating the linear relationship between the gate voltage $V_{gk}$ under non-trigger current and $T_{j}$ effect. The proposed TSEP does not affect the operating state of the thyristor and is suitable for complex operating conditions since it is extracted during OFF state. The total error in the $T_{j}$ estimate obtained from the proposed TSEP is verified within ±2 °C by comparing with the $T_{j}$ obtained from the traditional gate voltage $V_{GK}$ based TSEP during ON state.