Fujun Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fujun Zheng has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Haoze Luo
Zhejiang University
2 shared publications - Ankang Zhu
College of Electrical Engineering, Zhejiang University, Hangzhou, China
1 shared publication - Dong Hai
College of Electrical Engineering, Zhejiang University, Hangzhou, China
1 shared publication - Hongyi Gao
College of Electrical Engineering, Zhejiang University, Hangzhou, China
1 shared publication - Hui Meng
State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology, Tianjin, China
1 shared publication - Jianlong Kang
State Key Laboratory of Intelligent Power Distribution Equipment and System, Hebei University of Technology, Tianjin, China
1 shared publication
Latest Publications
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2270-2280
Improved Short-Circuit Protection Method for SiC MOSFET Split-Output Power Module Achieving Ultra-Low Fault Dissipated Energy
Due to ultrafast switching speed and high-frequency switching of silicon carbide (SiC) metal-oxide-semiconductor field-effect transistor ( mosfet s), crosstalk effect, high turn- on losses and electromagnetic interference are becoming constraints to the efficient and safe applications of SiC mosfet s. The split-output structure has attracted widespread attention due to its advantages of overcoming the above constraints by integrating decoupling inductors. Thereby, it fully exploits the potential benefits of SiC mosfet s. In this article, the effects of the split inductors on short-circuit characteristics of split-output power module are analyzed. An analytical model of the split-output power module is established to compare the electrical characteristics of the split inductors under normal operation and short-circuit faults. A dedicated short-circuit protection method is proposed based on the detection of the voltage pulse duration across the split inductors. The protection method is validated by hard switching fault and fault under load experiments. The results show that the short-circuit power device can be shut down when the short-circuit current is much lower than the continuous drain current. Besides, the short-circuit energy of the power device has the same order of magnitude as the dissipated energy under normal switching, which avoids degradation and even destruction of SiC mosfet s under short-circuit faults.
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2270-2280
Improved Short-Circuit Protection Method for SiC MOSFET Split-Output Power Module Achieving Ultra-Low Fault Dissipated Energy
Due to ultrafast switching speed and high-frequency switching of silicon carbide (SiC) metal-oxide-semiconductor field-effect transistor ( mosfet s), crosstalk effect, high turn- on losses and electromagnetic interference are becoming constraints to the efficient and safe applications of SiC mosfet s. The split-output structure has attracted widespread attention due to its advantages of overcoming the above constraints by integrating decoupling inductors. Thereby, it fully exploits the potential benefits of SiC mosfet s. In this article, the effects of the split inductors on short-circuit characteristics of split-output power module are analyzed. An analytical model of the split-output power module is established to compare the electrical characteristics of the split inductors under normal operation and short-circuit faults. A dedicated short-circuit protection method is proposed based on the detection of the voltage pulse duration across the split inductors. The protection method is validated by hard switching fault and fault under load experiments. The results show that the short-circuit power device can be shut down when the short-circuit current is much lower than the continuous drain current. Besides, the short-circuit energy of the power device has the same order of magnitude as the dissipated energy under normal switching, which avoids degradation and even destruction of SiC mosfet s under short-circuit faults.
- Open Access
- 26 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 4, 561-566
A Highly Precise On-State Voltage Measurement Circuit With Dual Current Sources for Online Operation of SiC MOSFETs
This letter proposes an on-state drain-source voltage (Vds,on) measurement circuit for SiC MOSFETs. The proposed circuit effectively solves the problem of inconsistent diode volt-ampere characteristics through an additional current source. The voltage difference between the two diodes is compensated by adjusting the auxiliary current under the condition of a fixed first current. This circuit does not require diode pre-selection and significantly improves measurement accuracy. The circuit is implemented in a double-pulse test (DPT) of a SiC MOSFET (900 V/23 A, 25 °C). The results show that the circuit has a fast response speed with a delay time of 0.4μs. Even at the same current, the forward voltage difference between the two diodes reaches 3.32 mV. Compared to measurement results from a six-bit semi-digital multimeter, the measurement error of the proposed circuit is less than 1.5% at different currents and temperatures.
- 26 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 4, 561-566
Open AccessA Highly Precise On-State Voltage Measurement Circuit With Dual Current Sources for Online Operation of SiC MOSFETs
This letter proposes an on-state drain-source voltage (Vds,on) measurement circuit for SiC MOSFETs. The proposed circuit effectively solves the problem of inconsistent diode volt-ampere characteristics through an additional current source. The voltage difference between the two diodes is compensated by adjusting the auxiliary current under the condition of a fixed first current. This circuit does not require diode pre-selection and significantly improves measurement accuracy. The circuit is implemented in a double-pulse test (DPT) of a SiC MOSFET (900 V/23 A, 25 °C). The results show that the circuit has a fast response speed with a delay time of 0.4μs. Even at the same current, the forward voltage difference between the two diodes reaches 3.32 mV. Compared to measurement results from a six-bit semi-digital multimeter, the measurement error of the proposed circuit is less than 1.5% at different currents and temperatures.