Tristan Gerard Vlogman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tristan Gerard Vlogman has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Kartik Jain
Department of Thermal and Fluid Engineering, University of Twente, Enschede, The Netherlands
5 shared publications - Erik Groot Jebbink
Multi-Modality Medical Imaging Group, University of Twente, Enschede, The Netherlands
4 shared publications - Tess Josien Snoeijink
Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
4 shared publications - Jan Lucas van der Hoek
Multi-modality medical imaging, Technical Medical Centre, Faculty of Science and Technology, University of Twente, P.O. Box 217, Enschede, The Netherlands
3 shared publications - Joey Roosen
Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
3 shared publications - Johannes Frank Wilhelmus Nijsen
Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
3 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 25 (5) , 108
Impact of catheter angle on microsphere distribution in transarterial radioembolization: an in silico study based on ex vivo porcine liver data
Computational fluid dynamics (CFD) simulations were conducted to explore the impact of catheter angle on microsphere distribution in transarterial radioembolization (TARE). The models were designed to closely replicate conditions from previously conducted ex vivo machine-perfused porcine liver experiments and therefore improve the perspective on microsphere distribution patterns. TARE with holmium-loaded microspheres was performed on an ex vivo machine-perfused porcine liver. Catheter position was imaged using angiography and ultrasound, the hepatic arterial vasculature using 3D cone beam CT, and lobe-specific microsphere distributions using holmium-sensitive T2*-weighted MRI scans. An in-house CFD model based on lattice Boltzmann and discrete element methods was developed. Simulations were parameterized with ex vivo porcine liver geometry and flow conditions as input. To further explore the role of catheter angles beyond experimental findings, four catheter angles (0°, 15°, 30°, and 45°), gradually directed toward the hepatic arterial wall, were evaluated using CFD. Ex vivo ultrasound imaging showed that the catheter was oriented at an angle of 25.2° toward the hepatic arterial wall. The simulations revealed that catheter angle strongly influences microsphere distribution, particularly in the branches closest to the injection position (lobe 3–5). The correlation between ex vivo and simulated microsphere distributions increased with catheter angle: from poor at 0° (r = 0.123), to moderate at 15° (r = 0.511), to very strong at 30° and 45° (r = 0.809 and r = 0.807, respectively). A catheter angle directed toward the hepatic arterial wall can affect microsphere distribution. In current clinical practice, the radial catheter position is not routinely visualized, complicating the reproducibility of catheter tip positioning between scout and therapeutic doses. Future research could focus on improved catheter tip visualization and the development of more stable catheter designs to enhance the reproducibility and efficacy of TARE.
- 21 September 2026
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 25 (5) , 108
Open AccessImpact of catheter angle on microsphere distribution in transarterial radioembolization: an in silico study based on ex vivo porcine liver data
Computational fluid dynamics (CFD) simulations were conducted to explore the impact of catheter angle on microsphere distribution in transarterial radioembolization (TARE). The models were designed to closely replicate conditions from previously conducted ex vivo machine-perfused porcine liver experiments and therefore improve the perspective on microsphere distribution patterns. TARE with holmium-loaded microspheres was performed on an ex vivo machine-perfused porcine liver. Catheter position was imaged using angiography and ultrasound, the hepatic arterial vasculature using 3D cone beam CT, and lobe-specific microsphere distributions using holmium-sensitive T2*-weighted MRI scans. An in-house CFD model based on lattice Boltzmann and discrete element methods was developed. Simulations were parameterized with ex vivo porcine liver geometry and flow conditions as input. To further explore the role of catheter angles beyond experimental findings, four catheter angles (0°, 15°, 30°, and 45°), gradually directed toward the hepatic arterial wall, were evaluated using CFD. Ex vivo ultrasound imaging showed that the catheter was oriented at an angle of 25.2° toward the hepatic arterial wall. The simulations revealed that catheter angle strongly influences microsphere distribution, particularly in the branches closest to the injection position (lobe 3–5). The correlation between ex vivo and simulated microsphere distributions increased with catheter angle: from poor at 0° (r = 0.123), to moderate at 15° (r = 0.511), to very strong at 30° and 45° (r = 0.809 and r = 0.807, respectively). A catheter angle directed toward the hepatic arterial wall can affect microsphere distribution. In current clinical practice, the radial catheter position is not routinely visualized, complicating the reproducibility of catheter tip positioning between scout and therapeutic doses. Future research could focus on improved catheter tip visualization and the development of more stable catheter designs to enhance the reproducibility and efficacy of TARE.
- Open Access
- 1 April 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (4)
Impact of injection velocity on catheter-based drug delivery in bifurcating vessels: In silico and in vitro analysis
Many biomedical applications involve the transport of fluid and/or particles in bifurcating vessels, such as aerosol transport in the lungs and transarterial radioembolization (TARE). Inspired by TARE, we study the injection of fluid via a catheter in an idealized liver vasculature through experiments and lattice Boltzmann simulations. First, we validate the simulations using in vitro experiments of dye injected through a catheter. Then, we investigate the impact of catheter injection velocity on the distribution of injected fluid. The sensitivity of the distributions to changes in flow rate is low at catheter flow rates Qc≤6mLmin−1 and Qc≥11mLmin−1, while in the intermediate regime, changes in flow rate of only 2 ml/min lead to changes in distribution of more than 50%. This is shown to originate from changes in the flow field in the first bifurcation. Specifically, the sensitivity to flow rate becomes large as the jet breakdown length approaches the distance to the first bifurcation. Our work represents a first step toward a fundamental understanding of the effect of injection velocity in TARE and similar applications.
- 1 April 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (4)
Open AccessImpact of injection velocity on catheter-based drug delivery in bifurcating vessels: In silico and in vitro analysis
Many biomedical applications involve the transport of fluid and/or particles in bifurcating vessels, such as aerosol transport in the lungs and transarterial radioembolization (TARE). Inspired by TARE, we study the injection of fluid via a catheter in an idealized liver vasculature through experiments and lattice Boltzmann simulations. First, we validate the simulations using in vitro experiments of dye injected through a catheter. Then, we investigate the impact of catheter injection velocity on the distribution of injected fluid. The sensitivity of the distributions to changes in flow rate is low at catheter flow rates Qc≤6mLmin−1 and Qc≥11mLmin−1, while in the intermediate regime, changes in flow rate of only 2 ml/min lead to changes in distribution of more than 50%. This is shown to originate from changes in the flow field in the first bifurcation. Specifically, the sensitivity to flow rate becomes large as the jet breakdown length approaches the distance to the first bifurcation. Our work represents a first step toward a fundamental understanding of the effect of injection velocity in TARE and similar applications.
- Open Access
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (3)
A systematic comparison of fully resolved and unresolved particulate flow simulations using the lattice Boltzmann and discrete element methods
Numerical simulations are widely used to study the behavior of suspension flows. Fully resolved simulations, in which the detailed flow around individual particles is computed, are accurate but computationally expensive. Unresolved methods reduce the computational cost significantly by only resolving the bulk flow and modeling the small-scale flow around particles. However, the degree to which modeling rather than computing the small-scale flow field information affects the predicted behavior of suspension flows is largely unknown. Here, we examine the steady homogeneous regime by simulating the pressure drop over a porous medium and the apparent viscosity of a sheared suspension as well as the transient heterogeneous regime by simulating a particle-induced Rayleigh–Taylor instability. From these simulations, we observe that unresolved methods are able to predict macroscopic quantities in steady state problems involving homogeneous suspensions but fail to capture particle entrainment, deformation, and breakup effects in transient problems involving heterogeneous suspensions. Our results suggest that the effect of the small-scale flow fields plays an important role in the onset and growth of instabilities in suspension flows which cannot be modeled in a trivial way. This has consequences for practical applications where such instabilities are essential, such as particle mixing. Further research into the mechanisms by which such instabilities are triggered as well as ways to include these effects in computationally inexpensive unresolved models is needed.
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (3)
Open AccessA systematic comparison of fully resolved and unresolved particulate flow simulations using the lattice Boltzmann and discrete element methods
Numerical simulations are widely used to study the behavior of suspension flows. Fully resolved simulations, in which the detailed flow around individual particles is computed, are accurate but computationally expensive. Unresolved methods reduce the computational cost significantly by only resolving the bulk flow and modeling the small-scale flow around particles. However, the degree to which modeling rather than computing the small-scale flow field information affects the predicted behavior of suspension flows is largely unknown. Here, we examine the steady homogeneous regime by simulating the pressure drop over a porous medium and the apparent viscosity of a sheared suspension as well as the transient heterogeneous regime by simulating a particle-induced Rayleigh–Taylor instability. From these simulations, we observe that unresolved methods are able to predict macroscopic quantities in steady state problems involving homogeneous suspensions but fail to capture particle entrainment, deformation, and breakup effects in transient problems involving heterogeneous suspensions. Our results suggest that the effect of the small-scale flow fields plays an important role in the onset and growth of instabilities in suspension flows which cannot be modeled in a trivial way. This has consequences for practical applications where such instabilities are essential, such as particle mixing. Further research into the mechanisms by which such instabilities are triggered as well as ways to include these effects in computationally inexpensive unresolved models is needed.
- Open Access
- 24 February 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (4) , 1783-1793
In Vitro Investigation of Microcatheter Behavior During Microsphere Injection in Transarterial Radioembolization
Purpose: To experimentally investigate the behavior of a clinically used microcatheter during transarterial radioembolization (TARE) microsphere injection in a successively bifurcating in vitro model. Materials and Methods: A symmetrical phantom was developed which bifurcated 3 times into 8 outlets. A blood-mimicking fluid was pumped through the phantom using a physiological representative waveform. Holmium-165 microspheres were injected in a pulsed manner at 3 different locations using a standard microcatheter and a rigid counterpart with same dimensions as a control. Motion of the catheter was studied with a top- and side-view camera on the phantom. Microspheres were collected at each outlet and their distribution over the 8 outlets was analyzed. Results: Due to the pulsatile flow in the phantom, strengthened by the pulsatile microsphere injection, the clinical catheter showed maximum displacements of 0.87 mm within a vessel with a diameter of 3.6 mm. This motion resulted in a different microsphere distribution for the clinical catheter compared with the rigid counterpart (75.9% vs 49.4% of the microspheres went to outlet 1–4, respectively). Conclusion: In this in vitro model, the motion of the clinical catheter affected distribution of microspheres. Since the pulsatile administration of microspheres resulted in increased motion of the clinical catheter, standardizing microsphere administration could be beneficial to reduce interprocedural differences in TARE. Clinical Impact: Our study demonstrated that microsphere distribution during transarterial radioembolization (TARE) is affected by catheter motion. Furthermore, increased catheter motion was observed as a result of the injection profile. Predictive tools such as the contrast CBCT and scout dose use different injection profiles compared to therapeutic TARE injections, potentially altering catheter tip behaviour and microsphere distribution, which could compromise their predictive values. Additionally, current TARE microsphere injection guidelines provide limited details, which may lead to variability across institutes and interventional radiologists. Standardizing injection techniques could reduce catheter motion variability and may facilitate more consistent and predictable microsphere distribution patterns.
- 24 February 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (4) , 1783-1793
Open AccessIn Vitro Investigation of Microcatheter Behavior During Microsphere Injection in Transarterial Radioembolization
Purpose: To experimentally investigate the behavior of a clinically used microcatheter during transarterial radioembolization (TARE) microsphere injection in a successively bifurcating in vitro model. Materials and Methods: A symmetrical phantom was developed which bifurcated 3 times into 8 outlets. A blood-mimicking fluid was pumped through the phantom using a physiological representative waveform. Holmium-165 microspheres were injected in a pulsed manner at 3 different locations using a standard microcatheter and a rigid counterpart with same dimensions as a control. Motion of the catheter was studied with a top- and side-view camera on the phantom. Microspheres were collected at each outlet and their distribution over the 8 outlets was analyzed. Results: Due to the pulsatile flow in the phantom, strengthened by the pulsatile microsphere injection, the clinical catheter showed maximum displacements of 0.87 mm within a vessel with a diameter of 3.6 mm. This motion resulted in a different microsphere distribution for the clinical catheter compared with the rigid counterpart (75.9% vs 49.4% of the microspheres went to outlet 1–4, respectively). Conclusion: In this in vitro model, the motion of the clinical catheter affected distribution of microspheres. Since the pulsatile administration of microspheres resulted in increased motion of the clinical catheter, standardizing microsphere administration could be beneficial to reduce interprocedural differences in TARE. Clinical Impact: Our study demonstrated that microsphere distribution during transarterial radioembolization (TARE) is affected by catheter motion. Furthermore, increased catheter motion was observed as a result of the injection profile. Predictive tools such as the contrast CBCT and scout dose use different injection profiles compared to therapeutic TARE injections, potentially altering catheter tip behaviour and microsphere distribution, which could compromise their predictive values. Additionally, current TARE microsphere injection guidelines provide limited details, which may lead to variability across institutes and interventional radiologists. Standardizing injection techniques could reduce catheter motion variability and may facilitate more consistent and predictable microsphere distribution patterns.
- Open Access
- 15 October 2024
- Published by Elsevier in Computers & Mathematics with Applications
- Vol. 175, 313-329
Efficient coupled lattice Boltzmann and Discrete Element Method simulations of small particles in complex geometries
- 15 October 2024
- Published by Elsevier in Computers & Mathematics with Applications
- Vol. 175, 313-329
Open AccessEfficient coupled lattice Boltzmann and Discrete Element Method simulations of small particles in complex geometries
- Open Access
- 21 June 2023
- Published by Taylor & Francis in Drug Delivery
- Vol. 30 (1) , 2226366
Transarterial radioembolization: a systematic review on gaining control over the parameters that influence microsphere distribution
[Purpose] Transarterial radioembolization (TARE) is an established treatment modality for patients with unresectable liver cancer. However, a better understanding of treatment parameters that influence microsphere distribution could further improve the therapy. This systematic review examines and summarizes the available evidence on intraprocedural parameters that influence the microsphere distribution during TARE as investigated by in vivo, ex vivo, in vitro and in silico studies. [Methods] A standardized search was performed in Medline, Embase and Web of Science to identify all published articles investigating microsphere distribution or dynamics during TARE. Studies presenting original research on parameters influencing the microsphere distribution during TARE were included. [Results] A total of 42 studies reporting a total of 11 different parameters were included for narrative analysis. The investigated studies suggest that flow distribution is not a perfect predictor of microsphere distribution. Increasing the injection velocity may help increase the similarity between flow and microsphere distributions. Furthermore, the microsphere distributions are very sensitive to the radial and axial catheter position. [Conclusion] The most promising parameters for future research which can be controlled in the clinic appear to be microsphere injection velocity as well as the axial catheter position. Up to now, many of the included studies do not take clinical feasibility into account, limiting the translation of results to clinical settings. Future research should therefore focus on the applicability of in vivo, in vitro, or in silico research to patient specific scenarios to improve the efficacy of radioembolization as treatment for liver cancer.
- 21 June 2023
- Published by Taylor & Francis in Drug Delivery
- Vol. 30 (1) , 2226366
Open AccessTransarterial radioembolization: a systematic review on gaining control over the parameters that influence microsphere distribution
[Purpose] Transarterial radioembolization (TARE) is an established treatment modality for patients with unresectable liver cancer. However, a better understanding of treatment parameters that influence microsphere distribution could further improve the therapy. This systematic review examines and summarizes the available evidence on intraprocedural parameters that influence the microsphere distribution during TARE as investigated by in vivo, ex vivo, in vitro and in silico studies. [Methods] A standardized search was performed in Medline, Embase and Web of Science to identify all published articles investigating microsphere distribution or dynamics during TARE. Studies presenting original research on parameters influencing the microsphere distribution during TARE were included. [Results] A total of 42 studies reporting a total of 11 different parameters were included for narrative analysis. The investigated studies suggest that flow distribution is not a perfect predictor of microsphere distribution. Increasing the injection velocity may help increase the similarity between flow and microsphere distributions. Furthermore, the microsphere distributions are very sensitive to the radial and axial catheter position. [Conclusion] The most promising parameters for future research which can be controlled in the clinic appear to be microsphere injection velocity as well as the axial catheter position. Up to now, many of the included studies do not take clinical feasibility into account, limiting the translation of results to clinical settings. Future research should therefore focus on the applicability of in vivo, in vitro, or in silico research to patient specific scenarios to improve the efficacy of radioembolization as treatment for liver cancer.