    Impact of catheter angle on microsphere distribution in transarterial radioembolization: an in silico study based on ex vivo porcine liver data

    by Tess J. Snoeijink, Tristan G. Vlogman, Anne van Den Brekel, Jan L. van der Hoek, Joey Roosen, Erik Groot Jebbink, Kartik Jain, J. Frank W. Nijsen

    Computational fluid dynamics (CFD) simulations were conducted to explore the impact of catheter angle on microsphere distribution in transarterial radioembolization (TARE). The models were designed to closely replicate conditions from previously conducted ex vivo machine-perfused porcine liver experiments and therefore improve the perspective on microsphere distribution patterns. TARE with holmium-loaded microspheres was performed on an ex vivo machine-perfused porcine liver. Catheter position was imaged using angiography and ultrasound, the hepatic arterial vasculature using 3D cone beam CT, and lobe-specific microsphere distributions using holmium-sensitive T2*-weighted MRI scans. An in-house CFD model based on lattice Boltzmann and discrete element methods was developed. Simulations were parameterized with ex vivo porcine liver geometry and flow conditions as input. To further explore the role of catheter angles beyond experimental findings, four catheter angles (0°, 15°, 30°, and 45°), gradually directed toward the hepatic arterial wall, were evaluated using CFD. Ex vivo ultrasound imaging showed that the catheter was oriented at an angle of 25.2° toward the hepatic arterial wall. The simulations revealed that catheter angle strongly influences microsphere distribution, particularly in the branches closest to the injection position (lobe 3–5). The correlation between ex vivo and simulated microsphere distributions increased with catheter angle: from poor at 0° (r = 0.123), to moderate at 15° (r = 0.511), to very strong at 30° and 45° (r = 0.809 and r = 0.807, respectively). A catheter angle directed toward the hepatic arterial wall can affect microsphere distribution. In current clinical practice, the radial catheter position is not routinely visualized, complicating the reproducibility of catheter tip positioning between scout and therapeutic doses. Future research could focus on improved catheter tip visualization and the development of more stable catheter designs to enhance the reproducibility and efficacy of TARE.

  • Open Access

    Dynamic contrast-enhanced ultrasound predicts microsphere biodistribution in real-time during transarterial radioembolization

    by J. L. van der Hoek, T. J. Snoeijink, A. Visser, K. D. E. de Bree, M. E. Krommendijk, J. G. M. Greve, H. R. Liefers, W. M. Brink, M. Versluis, J. Arens, et al.

    Background: Transarterial radioembolization (TARE) treatment efficacy critically depends on the microsphere biodistribution in the liver. Current treatment planning protocols rely on a pre-treatment scout procedure to evaluate this biodistribution for a selected catheter configuration. However, replication of the catheter configuration during treatment is challenging and often results in suboptimal tumor targeting. Here we present and experimentally validate a concept to improve tumor targeting using dynamic contrast-enhanced ultrasound (DCE-US) imaging to predict the microsphere biodistribution in real-time, using ultrasound contrast microbubbles as microsphere precursors. Methods: DCE-US-guided TARE was performed in three ex vivo perfused porcine livers using a customized normothermic machine-perfusion platform. In each liver, one lobe was selected for targeting, and a 9L4 ultrasound transducer was fixed to image this location. A microcatheter was inserted in the hepatic artery under fluoroscopic guidance. Several catheter positions were analyzed in real-time using ultrasound contrast microbubbles and time-intensity curves (TICs). The catheter position was optimized based on peak TIC intensity, which was retained for subsequent injection of non-irradiated 165 Ho-microspheres. The resulting microsphere biodistribution was evaluated by R2 * mapping in MRI. Results: Here we show that DCE-US can be used to identify feeding arteries, enabling optimization of the catheter placement to maximize peak intensity within the target lobe. MRI confirms the relative microsphere biodistribution as predicted by DCE-US in two quantifiable cases (Case 2: 99.2% [MRI] vs. 98% [DCE-US]; Case 3: 70.2% [MRI] vs. 80.9% [DCE-US]). Conclusions: DCE-US enables accurate prediction of microsphere biodistribution, providing real-time feedback for immediate intra-operative optimization of the catheter position during TARE.

  • Open Access

    Feasibility of Laser Speckle-Based Perfusion Imaging in an Ex-Vivo Liver Model

    by Ata Chizari, Jan L. van der Hoek, Anne R. D. Rook, Marleen E. Krommendijk, Tess J. Snoeijink, Adrie Visser, Tom Knop, Jutta Arens, Srirang Manohar, Wiendelt Steenbergen, et al.

    Objective: Advancing microcirculatory perfusion assessment methods is crucial for evaluating organ status during ex-vivo organ preservation and expanding the donor pool. This study demonstrates the feasibility of microcirculatory perfusion imaging in an ex-vivo liver model under normothermic machine perfusion, using two non-contact imaging techniques: laser Doppler perfusion imaging (LDPI) and laser speckle contrast imaging (LSCI). Methods and procedures: An ex-vivo porcine liver was perfused with oxygenated blood for 3 hours. Blood samples were collected every 30 minutes from the hepatic artery and portal vein to evaluate the liver’s overall status. Each of the five liver lobes was imaged every 15 minutes using both the in-house developed LDPI and wireless LSCI devices. Temporally averaged perfusion maps were analyzed to assess spatiotemporal blood flow. Then, correlations between LDPI and LSCI perfusion indices were evaluated. Results: Spatiotemporal perfusion images showed detailed superficial microcirculatory perfusion across five imaged lobes. High correlations between LDPI and LSCI indices were observed in lobes 3−5 (R2 = 0.81), which were well-perfused. Blood lactate levels increased over time, indicating a shift in metabolic activity due to ischemia. Also, correlation of LSCI perfusion indices with pH (R2max. = 0.95) was observed. Conclusion: The ex-vivo liver model mimics in-vivo perfusion under controlled experimental conditions. LDPI and LSCI provide rapid, independent assessments of local microcirculatory blood flow, demonstrate a high inter-technique correlation, and reflect the overall deterioration of liver status, as evidenced by blood gas parameters. Significance: A compact, wireless LSCI system—validated against LDPI—enables non-invasive evaluation of microcirculatory status and serves as a complementary tool for assessing deep tissue viability. Clinical and Translational Impact Statement: We introduce a wireless, compact, and non-contact LSCI system (validated by LDPI) enabling microcirculatory assessment during machine perfusion, complementing deep tissue medical imaging methods and blood gas analysis to enhance organ viability evaluation and support pre-transplantation treatment decisions (Category: Pre-Clinical Research).


  • Open Access

    Impact of injection velocity on catheter-based drug delivery in bifurcating vessels: In silico and in vitro analysis

    by Tristan Vlogman, Jan van der Hoek, Tess Snoeijink, Rob Hagmeijer, Erik Groot Jebbink, Kartik Jain

    Many biomedical applications involve the transport of fluid and/or particles in bifurcating vessels, such as aerosol transport in the lungs and transarterial radioembolization (TARE). Inspired by TARE, we study the injection of fluid via a catheter in an idealized liver vasculature through experiments and lattice Boltzmann simulations. First, we validate the simulations using in vitro experiments of dye injected through a catheter. Then, we investigate the impact of catheter injection velocity on the distribution of injected fluid. The sensitivity of the distributions to changes in flow rate is low at catheter flow rates Qc≤6mLmin−1 and Qc≥11mLmin−1, while in the intermediate regime, changes in flow rate of only 2 ml/min lead to changes in distribution of more than 50%. This is shown to originate from changes in the flow field in the first bifurcation. Specifically, the sensitivity to flow rate becomes large as the jet breakdown length approaches the distance to the first bifurcation. Our work represents a first step toward a fundamental understanding of the effect of injection velocity in TARE and similar applications.


  • Open Access

    In Vitro Investigation of Microcatheter Behavior During Microsphere Injection in Transarterial Radioembolization

    by Tess Josien Snoeijink, Jan Lucas van der Hoek, Hadi Mirgolbabaee, Tristan Gerard Vlogman, Joey Roosen, Johannes Frank Wilhelmus Nijsen, Erik Groot Jebbink

    Purpose: To experimentally investigate the behavior of a clinically used microcatheter during transarterial radioembolization (TARE) microsphere injection in a successively bifurcating in vitro model. Materials and Methods: A symmetrical phantom was developed which bifurcated 3 times into 8 outlets. A blood-mimicking fluid was pumped through the phantom using a physiological representative waveform. Holmium-165 microspheres were injected in a pulsed manner at 3 different locations using a standard microcatheter and a rigid counterpart with same dimensions as a control. Motion of the catheter was studied with a top- and side-view camera on the phantom. Microspheres were collected at each outlet and their distribution over the 8 outlets was analyzed. Results: Due to the pulsatile flow in the phantom, strengthened by the pulsatile microsphere injection, the clinical catheter showed maximum displacements of 0.87 mm within a vessel with a diameter of 3.6 mm. This motion resulted in a different microsphere distribution for the clinical catheter compared with the rigid counterpart (75.9% vs 49.4% of the microspheres went to outlet 1–4, respectively). Conclusion: In this in vitro model, the motion of the clinical catheter affected distribution of microspheres. Since the pulsatile administration of microspheres resulted in increased motion of the clinical catheter, standardizing microsphere administration could be beneficial to reduce interprocedural differences in TARE. Clinical Impact: Our study demonstrated that microsphere distribution during transarterial radioembolization (TARE) is affected by catheter motion. Furthermore, increased catheter motion was observed as a result of the injection profile. Predictive tools such as the contrast CBCT and scout dose use different injection profiles compared to therapeutic TARE injections, potentially altering catheter tip behaviour and microsphere distribution, which could compromise their predictive values. Additionally, current TARE microsphere injection guidelines provide limited details, which may lead to variability across institutes and interventional radiologists. Standardizing injection techniques could reduce catheter motion variability and may facilitate more consistent and predictable microsphere distribution patterns.