Hao Zeng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hao Zeng has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Changqin Fu
Aviation Engineering School, Air Force Engineering University, Xi’an 710038, China
4 shared publications - Rui Xi
Air Force Engineering University, Xi’an 710038, China
3 shared publications - Jingbo Peng
Aviation Engineering School, Air Force Engineering University, Xi’an 710038, China
2 shared publications - Lu Jia
Air Force Engineering University, Xi’an 710038, China
2 shared publications - Xinyao Hou
Aviation Engineering School, Air Force Engineering University, Xi’an 710038, China
2 shared publications - Zhiyu Zhao
Aviation Engineering School, Air Force Engineering University, Xi’an 710038, China
2 shared publications
Latest Publications
- Open Access
Research on the Cooling Characteristics of the Circular Ring Structure of Aircraft Engine Endoscope Probes
Aircraft engine endoscope probes often face difficulties in effectively detecting internal structures in high-temperature environments. In order to improve the thermal protection characteristics of endoscope probes, this paper designs a probe-cooling structure with a circular ring pressure drop structure and calculates and analyzes the cooling effect of the probe under different gas cooling conditions. Study the influence of size parameters and cooling medium properties of the structure on the cooling characteristics of the probe, analyze the temperature distribution of the probe mirror, cooling efficiency distribution, and cold flow outlet flow distribution. The results show that the larger the outlet width of the annular cooling structure, the better the cooling effect, and the optimal cooling effect structure is 0.7 mm; the larger the opening angle, the lower and then the higher the temperature of the endoscope probe surface, and the best cooling effect occurs when the optimal angle is 40°; the larger the proportion of mixed liquid nitrogen, the lower the temperature of the probe mirror surface. A 5% proportion of mixed liquid nitrogen can reduce the temperature of the probe mirror surface by about 11 K.
Open AccessResearch on the Cooling Characteristics of the Circular Ring Structure of Aircraft Engine Endoscope Probes
Aircraft engine endoscope probes often face difficulties in effectively detecting internal structures in high-temperature environments. In order to improve the thermal protection characteristics of endoscope probes, this paper designs a probe-cooling structure with a circular ring pressure drop structure and calculates and analyzes the cooling effect of the probe under different gas cooling conditions. Study the influence of size parameters and cooling medium properties of the structure on the cooling characteristics of the probe, analyze the temperature distribution of the probe mirror, cooling efficiency distribution, and cold flow outlet flow distribution. The results show that the larger the outlet width of the annular cooling structure, the better the cooling effect, and the optimal cooling effect structure is 0.7 mm; the larger the opening angle, the lower and then the higher the temperature of the endoscope probe surface, and the best cooling effect occurs when the optimal angle is 40°; the larger the proportion of mixed liquid nitrogen, the lower the temperature of the probe mirror surface. A 5% proportion of mixed liquid nitrogen can reduce the temperature of the probe mirror surface by about 11 K.
- Open Access
Simulation Study of Gas Cooling for Aero-Engine Borescope Probes
After an aero-engine shuts down, the high temperature within the core flow path prevents conventional borescope probes from performing immediate internal inspections due to their limited thermal resistance, thereby constraining rapid turnaround capabilities for aircraft. To address this challenge, this study proposes an active cooling strategy using coolant flow to keep the probe within a safe temperature range. Three cooling structures incorporating pressure-drop modules—annular, annular-slit, and round-hole configurations—were designed and numerically investigated to assess the effects of geometric parameters and coolant properties (temperature, pressure, nitrogen mixing ratio) on cooling performance. The results demonstrate that the round-hole structure with a 1.0 mm diameter achieves optimal cooling, maintaining an average probe mirror temperature of 286.2 K under coolant conditions of 285 K and 0.5 MPa. Cooling efficiency exhibits a strong linear negative correlation with coolant temperature, while its relationship with pressure is highly structure-dependent. Nitrogen doping significantly improves the heat transfer capacity of the coolant. The implemented three-stage pressure-drop module performs consistently, with the pressure loss per stage determined solely by the inlet pressure. This study provides valuable insights and a theoretical foundation for the design of high-temperature-resistant borescope equipment capable of operating in the harsh environments of aero-engines.
Open AccessSimulation Study of Gas Cooling for Aero-Engine Borescope Probes
After an aero-engine shuts down, the high temperature within the core flow path prevents conventional borescope probes from performing immediate internal inspections due to their limited thermal resistance, thereby constraining rapid turnaround capabilities for aircraft. To address this challenge, this study proposes an active cooling strategy using coolant flow to keep the probe within a safe temperature range. Three cooling structures incorporating pressure-drop modules—annular, annular-slit, and round-hole configurations—were designed and numerically investigated to assess the effects of geometric parameters and coolant properties (temperature, pressure, nitrogen mixing ratio) on cooling performance. The results demonstrate that the round-hole structure with a 1.0 mm diameter achieves optimal cooling, maintaining an average probe mirror temperature of 286.2 K under coolant conditions of 285 K and 0.5 MPa. Cooling efficiency exhibits a strong linear negative correlation with coolant temperature, while its relationship with pressure is highly structure-dependent. Nitrogen doping significantly improves the heat transfer capacity of the coolant. The implemented three-stage pressure-drop module performs consistently, with the pressure loss per stage determined solely by the inlet pressure. This study provides valuable insights and a theoretical foundation for the design of high-temperature-resistant borescope equipment capable of operating in the harsh environments of aero-engines.
- Open Access
Experimental Study on Working Characteristics of Microwave-Assisted Spark Plug Igniter
In this paper, a study on the working characteristics of microwave-assisted spark plug igniter was carried out. Experiments were carried out in a vacuum chamber to investigate the effects of microwave feeding with different parameters on the spark plug discharge process, breakdown voltage, average power, discharge spectral intensity, and characteristic temperature of the discharge plasma under different ambient pressures (0.1 MPa at atmospheric pressure and 0.05 MPa at low pressure). The results show that the breakdown voltage decreased by 15.2% and the average power of discharge increased by 49% when the microwave pulse peak power increased from 0 W to 200 W under a low-pressure environment; meanwhile, the breakdown voltage decreased by 10.8% and the average power increased by 23% under an atmospheric-pressure environment. When the microwave pulse frequency was increased from 1 kHz to 10 kHz, the breakdown voltage further decreased by 15.2% in a low-voltage environment, but there was no significant effect on the average power. The plasma characteristic temperature rose significantly with the peak power: the electron temperature rose from 1.961 eV to 2.154 eV with the power at atmospheric pressure, and the vibrational and rotational temperatures also increased significantly.
Open AccessExperimental Study on Working Characteristics of Microwave-Assisted Spark Plug Igniter
In this paper, a study on the working characteristics of microwave-assisted spark plug igniter was carried out. Experiments were carried out in a vacuum chamber to investigate the effects of microwave feeding with different parameters on the spark plug discharge process, breakdown voltage, average power, discharge spectral intensity, and characteristic temperature of the discharge plasma under different ambient pressures (0.1 MPa at atmospheric pressure and 0.05 MPa at low pressure). The results show that the breakdown voltage decreased by 15.2% and the average power of discharge increased by 49% when the microwave pulse peak power increased from 0 W to 200 W under a low-pressure environment; meanwhile, the breakdown voltage decreased by 10.8% and the average power increased by 23% under an atmospheric-pressure environment. When the microwave pulse frequency was increased from 1 kHz to 10 kHz, the breakdown voltage further decreased by 15.2% in a low-voltage environment, but there was no significant effect on the average power. The plasma characteristic temperature rose significantly with the peak power: the electron temperature rose from 1.961 eV to 2.154 eV with the power at atmospheric pressure, and the vibrational and rotational temperatures also increased significantly.
- Open Access
Study on Ignition Characteristics of Microwave Radiation Ignitor
This study explored methods used to improve the ignition efficiency of a microwave radiation igniter; experimental analyses were conducted to characterize the device’s performance in a model combustion chamber. High-speed imaging combined with an image intensifier tracked flame kernel formation and propagation dynamics under varying airflow rates, residual gas coefficients, and microwave pulse parameters. The results demonstrate that increased airflow rates reduced the relative decline in ignition delay time under microwave application, with the flame area growth curve exhibiting a steeper slope compared to non-microwave conditions. Elevated residual gas coefficients enhanced the microwave-induced reduction in ignition delay time, though this effect weakened significantly in fuel-rich environments. Additionally, higher microwave pulse frequencies and peak power levels both contributed to shorter ignition delay times; the delay decreased linearly with the rising pulse frequency and followed a power-dependent reduction trend. These findings systematically quantify the synergistic effects of flow dynamics, residual gases, and microwave parameters on ignition performance.
Open AccessStudy on Ignition Characteristics of Microwave Radiation Ignitor
This study explored methods used to improve the ignition efficiency of a microwave radiation igniter; experimental analyses were conducted to characterize the device’s performance in a model combustion chamber. High-speed imaging combined with an image intensifier tracked flame kernel formation and propagation dynamics under varying airflow rates, residual gas coefficients, and microwave pulse parameters. The results demonstrate that increased airflow rates reduced the relative decline in ignition delay time under microwave application, with the flame area growth curve exhibiting a steeper slope compared to non-microwave conditions. Elevated residual gas coefficients enhanced the microwave-induced reduction in ignition delay time, though this effect weakened significantly in fuel-rich environments. Additionally, higher microwave pulse frequencies and peak power levels both contributed to shorter ignition delay times; the delay decreased linearly with the rising pulse frequency and followed a power-dependent reduction trend. These findings systematically quantify the synergistic effects of flow dynamics, residual gases, and microwave parameters on ignition performance.
- Open Access
Study of Cooling Characteristics of Axisymmetric Tail Nozzle
In order to reduce the infrared radiation intensity of supersonic tail nozzles and in response to the increasingly severe battlefield infrared environment, simulations were conducted on axisymmetric expanding tail nozzles to study the effects of air, liquid nitrogen, and dry ice cold flows at different flow rates on the nozzle wall temperature. The results show that when the dry ice flow rate is increased by 1 kg/s, the maximum temperature of the wall surface in the expansion section decreases by about 40 K. At a cold flow rate of 5% in the 0° detection direction, the intensity of infrared radiation was reduced by 20.8% for the liquid nitrogen cold flow and 26.3% for the dry ice cold flow, compared to the cold flow of injected air. The IR suppression of the tail nozzle was significant in the range from α = 0 to 50°. Compared to cooling air, the maximum IR radiation intensity was reduced by 26.5% for dry ice and 20.4% for liquid nitrogen. When the flow rate of the injected cold stream was increased by 4%, the intensity of the infrared radiation from the nozzle was reduced by 52.6%, 55.8%, and 66.2% for the injected air, liquid nitrogen, and dry ice cold streams, respectively.
Open AccessStudy of Cooling Characteristics of Axisymmetric Tail Nozzle
In order to reduce the infrared radiation intensity of supersonic tail nozzles and in response to the increasingly severe battlefield infrared environment, simulations were conducted on axisymmetric expanding tail nozzles to study the effects of air, liquid nitrogen, and dry ice cold flows at different flow rates on the nozzle wall temperature. The results show that when the dry ice flow rate is increased by 1 kg/s, the maximum temperature of the wall surface in the expansion section decreases by about 40 K. At a cold flow rate of 5% in the 0° detection direction, the intensity of infrared radiation was reduced by 20.8% for the liquid nitrogen cold flow and 26.3% for the dry ice cold flow, compared to the cold flow of injected air. The IR suppression of the tail nozzle was significant in the range from α = 0 to 50°. Compared to cooling air, the maximum IR radiation intensity was reduced by 26.5% for dry ice and 20.4% for liquid nitrogen. When the flow rate of the injected cold stream was increased by 4%, the intensity of the infrared radiation from the nozzle was reduced by 52.6%, 55.8%, and 66.2% for the injected air, liquid nitrogen, and dry ice cold streams, respectively.
- Open Access
Study on Microwave-Assisted Ignition Using a Novel Aero-Engine Combustor
Microwave plasma can improve the performance of ignition and combustion, as well as reduce pollutant emissions. By designing a novel microwave feeding device, the combustor can be used as a cavity resonator to generate microwave plasma and improve the performance of ignition and combustion. In order to feed the energy of microwave into the combustor as much as possible, and effectively adapt to the change in resonance frequency of combustor during ignition and combustion, the combustor was designed and manufactured by optimizing the size of slot antenna and setting the tuning screws, according to the simulation results of HFSS software (version: 2019 R 3). The relationship between the size, position of metal tip in the combustor and the discharge voltage was studied using HFSS software, as well as the interaction between ignition kernel, flame and microwave. The resonant characteristics of combustor and the discharge of microwave-assisted igniter were subsequently studied via experiments. The results show that the combustor as microwave cavity resonator has a wider resonance curve and can adapt to the change in resonance frequency during ignition and combustion. It is also indicated that microwave can enhance the discharge development of igniter and increase the discharge size. Based on this, the electric and magnetic field effects of microwave are decoupled.
Open AccessStudy on Microwave-Assisted Ignition Using a Novel Aero-Engine Combustor
Microwave plasma can improve the performance of ignition and combustion, as well as reduce pollutant emissions. By designing a novel microwave feeding device, the combustor can be used as a cavity resonator to generate microwave plasma and improve the performance of ignition and combustion. In order to feed the energy of microwave into the combustor as much as possible, and effectively adapt to the change in resonance frequency of combustor during ignition and combustion, the combustor was designed and manufactured by optimizing the size of slot antenna and setting the tuning screws, according to the simulation results of HFSS software (version: 2019 R 3). The relationship between the size, position of metal tip in the combustor and the discharge voltage was studied using HFSS software, as well as the interaction between ignition kernel, flame and microwave. The resonant characteristics of combustor and the discharge of microwave-assisted igniter were subsequently studied via experiments. The results show that the combustor as microwave cavity resonator has a wider resonance curve and can adapt to the change in resonance frequency during ignition and combustion. It is also indicated that microwave can enhance the discharge development of igniter and increase the discharge size. Based on this, the electric and magnetic field effects of microwave are decoupled.