Mariana Gutiérrez-Sánchez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mariana Gutiérrez-Sánchez has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Verónica Méndez-González
PhD, Endodontics Postgraduate Program, Faculty of Stomatology, Autonomous University of San Luis Potosí, San Luis Potosí. Av. Dr. Manuel Nava #2, Zona Universitaria, 78290, San Luis Potosí, S.L.P. México
5 shared publications - Amaury Pozos-Guillén
Facultad de Estomatología, Laboratorio de Ciencias Básicas, Universidad Autónoma de San Luis Potosí, San Luis Potosí, Mexico
3 shared publications - Karla Navarrete-Olvera
Endodontics Postgraduate Program, Faculty of Stomatology, Autonomous University of San Luis Potosí, San Luis Potosí. Av. Dr. Manuel Nava #2, Zona Universitaria, 78290, San Luis Potosí, S.L.P. México
3 shared publications - Alejandro López Aldrete
PhD, Endodontics Postgraduate Program, Faculty of Stomatology, Autonomous University of San Luis Potosí, San Luis Potosí. Av. Dr. Manuel Nava #2, Zona Universitaria, 78290, San Luis Potosí, S.L.P. México
2 shared publications - Marine Ortiz-Magdaleno
PhD, Faculty of Stomatology, Autonomous University of San Luis Potosí, San Luis Potosí. Av. Dr. Manuel Nava #2, Zona Universitaria, 78290, San Luis Potosí, S.L.P. México
2 shared publications - Vladimir Alonso Escobar-Barrios
PhD, Advanced Materials Division, Instituto Potosino de Investigación Científica y Tecnológica A.C, San Luis Potosí, Mexico
2 shared publications
Latest Publications
- 14 September 2026
- Published by The Pinnacle International Journals in International Journal of Medical Science and Dental Health
- Vol. 12 (09) , 46-54
Characterization of Phase Transformations and Chemical Composition in Rotary and Reciprocating Nickel-Titanium Endodontic Instruments
Background: The mechanical stresses to which the files are subjected differ depending on the type of movement. Therefore, the flexibility and resistance of the instruments must vary according to clinical needs. Which depends on the chemical composition and thermal treatment of the material, which gives it the atomic arrangement. Objectives: Analyze the physical, chemical and thermal properties of rotary and reciprocating instruments. Methods: The reciprocating and rotary instrumentation systems: WaveOne Gold, Reciproc Blue, Vortex Blue and V-Taper were evaluated under SEM, as well as their chemical composition by ICP-OES analysis, the phase transitions through DSC, and structurally by X-ray diffraction. Results: Chemical analysis determined that the NiTi alloys, corresponding to Vortex Blue and V-Taper 2H, have an almost 1:1 Ni:Ti atomic ratio, but with a significant variation in the Ni content. Likewise, a low Au content was detected in the alternative WaveOne Gold system. Regarding the thermal analysis, the alternative V-taper 2H system showed a double exothermic transition associated with an intermediate rhombohedral phase known as R phase. The diffraction patterns show the transition of the austenitic phase. Conclusions: Thermochemical analysis, Rotary Instruments, Reciproc Blue, Vortex Blue, V-Taper 2H, and WaveOne Gold.
- 14 September 2026
- Published by The Pinnacle International Journals in International Journal of Medical Science and Dental Health
- Vol. 12 (09) , 46-54
Characterization of Phase Transformations and Chemical Composition in Rotary and Reciprocating Nickel-Titanium Endodontic Instruments
Background: The mechanical stresses to which the files are subjected differ depending on the type of movement. Therefore, the flexibility and resistance of the instruments must vary according to clinical needs. Which depends on the chemical composition and thermal treatment of the material, which gives it the atomic arrangement. Objectives: Analyze the physical, chemical and thermal properties of rotary and reciprocating instruments. Methods: The reciprocating and rotary instrumentation systems: WaveOne Gold, Reciproc Blue, Vortex Blue and V-Taper were evaluated under SEM, as well as their chemical composition by ICP-OES analysis, the phase transitions through DSC, and structurally by X-ray diffraction. Results: Chemical analysis determined that the NiTi alloys, corresponding to Vortex Blue and V-Taper 2H, have an almost 1:1 Ni:Ti atomic ratio, but with a significant variation in the Ni content. Likewise, a low Au content was detected in the alternative WaveOne Gold system. Regarding the thermal analysis, the alternative V-taper 2H system showed a double exothermic transition associated with an intermediate rhombohedral phase known as R phase. The diffraction patterns show the transition of the austenitic phase. Conclusions: Thermochemical analysis, Rotary Instruments, Reciproc Blue, Vortex Blue, V-Taper 2H, and WaveOne Gold.
- Open Access
- 21 June 2026
- Published by Caleo in European Endodontic Journal
- Vol. 11 (6) , 275-284
Comparative Efficacy of Rotary Versus Ultrasonic Supplementary Protocols for Bioceramic and Epoxy Resin Sealer Removal: A Micro-CT in Vitro Study
This study aimed to compare the efficacy of 2 retreatment protocols – SClean® file and R1 ClearSonic™ ultrasonic tip – in removing bioceramic (EndoSequence BC Sealer®, CeraSeal®, Kerr®) and epoxy resin-based (AH Plus®) sealers using micro‑CT analysis. One hundred and four extracted single-rooted teeth were divided into 8 groups according to sealer type and cleaning protocol. Residual sealer volume, surface area, and apical permeability were analysed using Mann–Whitney U and Kruskal–Wallis tests (α=0.05). No technique achieved complete removal, with the highest residue in the apical third. SClean® was more effective on bioceramic sealers (P < .05), while R1 ClearSonic™ showed no significant inter-sealer differences. Apical permeability recovery was greatest with bioceramic sealers, reaching 100% for EndoSequence BC Sealer®. In conclusion, bioceramic sealers are more easily eliminated than epoxy resin-based sealers, though complete removal – particularly apically – remains difficult.
- 21 June 2026
- Published by Caleo in European Endodontic Journal
- Vol. 11 (6) , 275-284
Open AccessComparative Efficacy of Rotary Versus Ultrasonic Supplementary Protocols for Bioceramic and Epoxy Resin Sealer Removal: A Micro-CT in Vitro Study
This study aimed to compare the efficacy of 2 retreatment protocols – SClean® file and R1 ClearSonic™ ultrasonic tip – in removing bioceramic (EndoSequence BC Sealer®, CeraSeal®, Kerr®) and epoxy resin-based (AH Plus®) sealers using micro‑CT analysis. One hundred and four extracted single-rooted teeth were divided into 8 groups according to sealer type and cleaning protocol. Residual sealer volume, surface area, and apical permeability were analysed using Mann–Whitney U and Kruskal–Wallis tests (α=0.05). No technique achieved complete removal, with the highest residue in the apical third. SClean® was more effective on bioceramic sealers (P < .05), while R1 ClearSonic™ showed no significant inter-sealer differences. Apical permeability recovery was greatest with bioceramic sealers, reaching 100% for EndoSequence BC Sealer®. In conclusion, bioceramic sealers are more easily eliminated than epoxy resin-based sealers, though complete removal – particularly apically – remains difficult.
- 29 April 2026
- Published by The Pinnacle International Journals in International Journal of Medical Science and Dental Health
- Vol. 12 (04) , 154-164
Comparative Evaluation of Minimally Invasive and Conventional Access on The Biofilm Elimination of Enterococcus Faecalis From the Root Canal System
Background: The access cavity is a fundamental step in endodontic treatment. Traditionally, it is performed by completely removing the pulp chamber and all its contents. Recently, the introduction of technologies such as the operating microscope, ultrasound, and Ni-Ti instrumentation systems has allowed this phase to be performed conservatively through minimal invasive access. However, further evidence is needed to determine whether these techniques allow complete elimination of microorganisms within the root canal system. Objectives: The aim of this study was to evaluate the effects of minimally invasive access (MIA) compared with conventional access (CA) on the disinfection and elimination of biofilm Enterococcus faecalis in root canal therapy. Methods: Forty-four first molars were selected and randomly divided in groups: MIA and CA (n= 15 each), positive control (n= 8), negative control (n= 6). After access cavity, the root canals were contaminated with E. faecalis for 30 days. Bacterial sampling was performed with sterile paper points before (S1) and after (S2) instrumentation with the TruNatomy system to quantify the bacterial load. Colony-forming units per milliliter (CFU/mL) and scanning electron microscopy (SEM) were used for bacterial reduction assessment and elimination of biofilm. Statistical comparisons were conducted using Student’s t-test or Mann–Whitney U test, with significance set at 5%. Results: Significant reductions in E. faecalis were observed in all groups, regardless of cavity design. However, the lowest bacterial reduction was found in the MIA group, while the CA group achieved the highest reduction. Conclusions: Conventional access resulted in significantly better disinfection compared with minimally invasive access. These findings suggest that the design of the access cavity influences bacterial load reduction and biofilm elimination within root canals.
- 29 April 2026
- Published by The Pinnacle International Journals in International Journal of Medical Science and Dental Health
- Vol. 12 (04) , 154-164
Comparative Evaluation of Minimally Invasive and Conventional Access on The Biofilm Elimination of Enterococcus Faecalis From the Root Canal System
Background: The access cavity is a fundamental step in endodontic treatment. Traditionally, it is performed by completely removing the pulp chamber and all its contents. Recently, the introduction of technologies such as the operating microscope, ultrasound, and Ni-Ti instrumentation systems has allowed this phase to be performed conservatively through minimal invasive access. However, further evidence is needed to determine whether these techniques allow complete elimination of microorganisms within the root canal system. Objectives: The aim of this study was to evaluate the effects of minimally invasive access (MIA) compared with conventional access (CA) on the disinfection and elimination of biofilm Enterococcus faecalis in root canal therapy. Methods: Forty-four first molars were selected and randomly divided in groups: MIA and CA (n= 15 each), positive control (n= 8), negative control (n= 6). After access cavity, the root canals were contaminated with E. faecalis for 30 days. Bacterial sampling was performed with sterile paper points before (S1) and after (S2) instrumentation with the TruNatomy system to quantify the bacterial load. Colony-forming units per milliliter (CFU/mL) and scanning electron microscopy (SEM) were used for bacterial reduction assessment and elimination of biofilm. Statistical comparisons were conducted using Student’s t-test or Mann–Whitney U test, with significance set at 5%. Results: Significant reductions in E. faecalis were observed in all groups, regardless of cavity design. However, the lowest bacterial reduction was found in the MIA group, while the CA group achieved the highest reduction. Conclusions: Conventional access resulted in significantly better disinfection compared with minimally invasive access. These findings suggest that the design of the access cavity influences bacterial load reduction and biofilm elimination within root canals.
- Open Access
- 29 August 2025
- Published by Universidad de Costa Rica in Odovtos - International Journal of Dental Sciences
- Vol. 27 (3) , 86-100
Influence of Thermal Treatment on Fracture Due to Cyclic Fatigue of Rotary Files
The objective of this study aimed to assess the cyclic fatigue fracture of ZenFlexTM, ProTaper GoldTM, and HyFlexTM. EDM rotary files in simulated curved canals, along with evaluating their physicochemical properties and thermal behavior. A total of 69 instruments from three different NiTi rotary file systems were utilized: ProTaper GoldTM (08/25), HyflexTM EDM (08/25), and ZenflexTM (06/25). The analysis consisted of four phases: Phase 1 involved SEM observation to detect manufacturing defects; Phase 2 focused on cyclic fatigue-induced fracture in a curved canal with a 60° radius of curvature of 2 mm and a diameter of 1.5 mm; Phase 3 encompassed SEM observation of the fractured fragment and obtaining a fractographic study; Phase 4 included physicochemical characterization, such as equiatomic relationships by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES), phase transformation by DSC, crystalline structure by X-ray diffraction, and morphological analysis by SEM. Microcracks and defects were observed on cutting edges of ZenFlexTM and ProTaper GoldTM files. The mean cycles to fracture were 2814.50±161.58, 2649.94±120.93, and 1362.89±88.33 for HyFlexTM, ZenFlexTM, and ProTaper GoldTM, respectively. Moreover, different phase transition temperatures were noted, with ZenFlexTM in the austenite phase, ProTaper GoldTM in martensite, and HyFlexTM in the R phase at room temperature, as corroborated by X-ray diffraction. Additionally, a quasi-equimolar relationship was observed for the different systems, with ZenFlexTM exhibiting a reduced helical angle, followed by HyFlexTM and ProTaper GoldTM. ZenFlexTM files demonstrated greater resistance to cyclic fatigue, which appeared to be attributed to their physicochemical properties, heat treatment, and design.
- 29 August 2025
- Published by Universidad de Costa Rica in Odovtos - International Journal of Dental Sciences
- Vol. 27 (3) , 86-100
Open AccessInfluence of Thermal Treatment on Fracture Due to Cyclic Fatigue of Rotary Files
The objective of this study aimed to assess the cyclic fatigue fracture of ZenFlexTM, ProTaper GoldTM, and HyFlexTM. EDM rotary files in simulated curved canals, along with evaluating their physicochemical properties and thermal behavior. A total of 69 instruments from three different NiTi rotary file systems were utilized: ProTaper GoldTM (08/25), HyflexTM EDM (08/25), and ZenflexTM (06/25). The analysis consisted of four phases: Phase 1 involved SEM observation to detect manufacturing defects; Phase 2 focused on cyclic fatigue-induced fracture in a curved canal with a 60° radius of curvature of 2 mm and a diameter of 1.5 mm; Phase 3 encompassed SEM observation of the fractured fragment and obtaining a fractographic study; Phase 4 included physicochemical characterization, such as equiatomic relationships by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES), phase transformation by DSC, crystalline structure by X-ray diffraction, and morphological analysis by SEM. Microcracks and defects were observed on cutting edges of ZenFlexTM and ProTaper GoldTM files. The mean cycles to fracture were 2814.50±161.58, 2649.94±120.93, and 1362.89±88.33 for HyFlexTM, ZenFlexTM, and ProTaper GoldTM, respectively. Moreover, different phase transition temperatures were noted, with ZenFlexTM in the austenite phase, ProTaper GoldTM in martensite, and HyFlexTM in the R phase at room temperature, as corroborated by X-ray diffraction. Additionally, a quasi-equimolar relationship was observed for the different systems, with ZenFlexTM exhibiting a reduced helical angle, followed by HyFlexTM and ProTaper GoldTM. ZenFlexTM files demonstrated greater resistance to cyclic fatigue, which appeared to be attributed to their physicochemical properties, heat treatment, and design.
- Open Access
- 26 April 2024
- Published by Universidad de Costa Rica in Odovtos - International Journal of Dental Sciences
- Vol. 26 (2) , 91-100
Biocompatibility of Bioactive Sealers Bio-C Sealer vs MTA Repair HP in Human Fibroblasts
Bioactive cements based on tricalcium silicate have been introducedto the market for use in dentistry, with a variety of clinical applications. These cements are in contact with vital tissues such as dental pulp or periodontium in cases of unintentional extrusion; thus, it is important to know the genotoxicity and cytoxicity of these materials. The objective of this study was to evaluate the cytotoxicity and genotoxicity of bioactive sealers, Bio-C® Sealer and MTA Repair HP®, in human fibroblasts. Discs of bioactive sealers Bio-C® Sealer, and MTA Repair HP®, were prepared and set for 24h under sterile conditions. The discs were placed in culture medium at 2.5mg/mL inside a SRT6D roller mixer (Stuart, UK) at 60rpm for 24h. The eluates obtained were incubated for 24h with previously activated and cultured ATCC cell line fibroblasts at 80% confluence. The cytotoxicity was evaluated by Alamar Blue® and LIVE/DEAD assays, as well as the analysis of the Tunel and Mitotracker assays to evaluate genotoxicity using the confocal laser-scanning microscope. In the Alamar Blue® assay, the Bio-C® Sealer presented a cell proliferation of 87%, while the MTA Repair HP® Sealer was 72%. A statistically significant difference was found between the MTA Repair HP® Sealant and the negative control (p=<0.001). Regarding the genotoxicity tests, in the Tunel assay, both materials stain the nucleus of the fibroblast cells exposed to the eluates, while in the Mitotracker assay, the MTA Repair HP® Sealer showed greater mitochondrial function than the Bio-C® Sealer. Calcium silicate-based sealers, Bio-C® Sealer and MTA Repair HP®, are not cytotoxic and have low genotoxicity.
- 26 April 2024
- Published by Universidad de Costa Rica in Odovtos - International Journal of Dental Sciences
- Vol. 26 (2) , 91-100
Open AccessBiocompatibility of Bioactive Sealers Bio-C Sealer vs MTA Repair HP in Human Fibroblasts
Bioactive cements based on tricalcium silicate have been introducedto the market for use in dentistry, with a variety of clinical applications. These cements are in contact with vital tissues such as dental pulp or periodontium in cases of unintentional extrusion; thus, it is important to know the genotoxicity and cytoxicity of these materials. The objective of this study was to evaluate the cytotoxicity and genotoxicity of bioactive sealers, Bio-C® Sealer and MTA Repair HP®, in human fibroblasts. Discs of bioactive sealers Bio-C® Sealer, and MTA Repair HP®, were prepared and set for 24h under sterile conditions. The discs were placed in culture medium at 2.5mg/mL inside a SRT6D roller mixer (Stuart, UK) at 60rpm for 24h. The eluates obtained were incubated for 24h with previously activated and cultured ATCC cell line fibroblasts at 80% confluence. The cytotoxicity was evaluated by Alamar Blue® and LIVE/DEAD assays, as well as the analysis of the Tunel and Mitotracker assays to evaluate genotoxicity using the confocal laser-scanning microscope. In the Alamar Blue® assay, the Bio-C® Sealer presented a cell proliferation of 87%, while the MTA Repair HP® Sealer was 72%. A statistically significant difference was found between the MTA Repair HP® Sealant and the negative control (p=<0.001). Regarding the genotoxicity tests, in the Tunel assay, both materials stain the nucleus of the fibroblast cells exposed to the eluates, while in the Mitotracker assay, the MTA Repair HP® Sealer showed greater mitochondrial function than the Bio-C® Sealer. Calcium silicate-based sealers, Bio-C® Sealer and MTA Repair HP®, are not cytotoxic and have low genotoxicity.
- 24 June 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (2) , 256.e1-256.e12
Effect of degree of conversion on the surface properties of polymerized resin cements used for luting glass fiber posts
- 24 June 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (2) , 256.e1-256.e12
Effect of degree of conversion on the surface properties of polymerized resin cements used for luting glass fiber posts