  • Characterization of Phase Transformations and Chemical Composition in Rotary and Reciprocating Nickel-Titanium Endodontic Instruments

    by Alejandro López-Aldrete, Marco Martin Mora-Chávez, María Verónica Méndez-González, Marine Ortiz Magdaleno, Vladimir Alonso Escobar-Barrios, Karla Patricia Navarrete-Olvera, Mariana Gutiérrez-Sánchez

    Background: The mechanical stresses to which the files are subjected differ depending on the type of movement. Therefore, the flexibility and resistance of the instruments must vary according to clinical needs. Which depends on the chemical composition and thermal treatment of the material, which gives it the atomic arrangement. Objectives: Analyze the physical, chemical and thermal properties of rotary and reciprocating instruments. Methods: The reciprocating and rotary instrumentation systems: WaveOne Gold, Reciproc Blue, Vortex Blue and V-Taper were evaluated under SEM, as well as their chemical composition by ICP-OES analysis, the phase transitions through DSC, and structurally by X-ray diffraction. Results: Chemical analysis determined that the NiTi alloys, corresponding to Vortex Blue and V-Taper 2H, have an almost 1:1 Ni:Ti atomic ratio, but with a significant variation in the Ni content. Likewise, a low Au content was detected in the alternative WaveOne Gold system. Regarding the thermal analysis, the alternative V-taper 2H system showed a double exothermic transition associated with an intermediate rhombohedral phase known as R phase. The diffraction patterns show the transition of the austenitic phase. Conclusions: Thermochemical analysis, Rotary Instruments, Reciproc Blue, Vortex Blue, V-Taper 2H, and WaveOne Gold.

  • Open Access

    Comparative Efficacy of Rotary Versus Ultrasonic Supplementary Protocols for Bioceramic and Epoxy Resin Sealer Removal: A Micro-CT in Vitro Study

    by Verónica-Méndez González, Rodrigo Vargas López, Amaury Pozos-Guillén, Karla Navarrete-Olvera, Mariana Gutiérrez-Sánchez, Dante Arteaga-Martínez, Arturo Garrocho-Rangel

    This study aimed to compare the efficacy of 2 retreatment protocols – SClean® file and R1 ClearSonic™ ultrasonic tip – in removing bioceramic (EndoSequence BC Sealer®, CeraSeal®, Kerr®) and epoxy resin-based (AH Plus®) sealers using micro‑CT analysis. One hundred and four extracted single-rooted teeth were divided into 8 groups according to sealer type and cleaning protocol. Residual sealer volume, surface area, and apical permeability were analysed using Mann–Whitney U and Kruskal–Wallis tests (α=0.05). No technique achieved complete removal, with the highest residue in the apical third. SClean® was more effective on bioceramic sealers (P < .05), while R1 ClearSonic™ showed no significant inter-sealer differences. Apical permeability recovery was greatest with bioceramic sealers, reaching 100% for EndoSequence BC Sealer®. In conclusion, bioceramic sealers are more easily eliminated than epoxy resin-based sealers, though complete removal – particularly apically – remains difficult.

  • Comparative Evaluation of Minimally Invasive and Conventional Access on The Biofilm Elimination of Enterococcus Faecalis From the Root Canal System

    by Verónica Méndez-González, Eladio Robledo, Alejandro López Aldrete, Erika Romero-Rodríguez, Mariana Gutiérrez-Sánchez, Karla Navarrete-Olvera

    Background: The access cavity is a fundamental step in endodontic treatment. Traditionally, it is performed by completely removing the pulp chamber and all its contents. Recently, the introduction of technologies such as the operating microscope, ultrasound, and Ni-Ti instrumentation systems has allowed this phase to be performed conservatively through minimal invasive access. However, further evidence is needed to determine whether these techniques allow complete elimination of microorganisms within the root canal system. Objectives: The aim of this study was to evaluate the effects of minimally invasive access (MIA) compared with conventional access (CA) on the disinfection and elimination of biofilm Enterococcus faecalis in root canal therapy. Methods: Forty-four first molars were selected and randomly divided in groups: MIA and CA (n= 15 each), positive control (n= 8), negative control (n= 6). After access cavity, the root canals were contaminated with E. faecalis for 30 days. Bacterial sampling was performed with sterile paper points before (S1) and after (S2) instrumentation with the TruNatomy system to quantify the bacterial load. Colony-forming units per milliliter (CFU/mL) and scanning electron microscopy (SEM) were used for bacterial reduction assessment and elimination of biofilm. Statistical comparisons were conducted using Student’s t-test or Mann–Whitney U test, with significance set at 5%. Results: Significant reductions in E. faecalis were observed in all groups, regardless of cavity design. However, the lowest bacterial reduction was found in the MIA group, while the CA group achieved the highest reduction. Conclusions: Conventional access resulted in significantly better disinfection compared with minimally invasive access. These findings suggest that the design of the access cavity influences bacterial load reduction and biofilm elimination within root canals.

  • Open Access

    The Push-Out Bond Strength, Surface Roughness, and Antimicrobial Properties of Endodontic Bioceramic Sealers Supplemented with Silver Nanoparticles

    by Karla Navarrete-Olvera, Nereyda Niño-Martínez, Idania De Alba-Montero, Nuria Patiño-Marín, Facundo Ruiz, Horacio Bach, Gabriel-Alejandro Martínez-Castañón

    This study evaluated push-out bond test (POBT), surface roughness, and antimicrobial properties against Enterococcus faecalis of bioceramic sealers supplemented with silver nanoparticles (AgNPs). The sealers tested were CeraSeal®, EndoSequence® BC SealerTM, and Bio-C® Sealer. The POBT was measured with a Universal Testing Machine, and the type of failure was evaluated with a stereomicroscope. The roughness average (Sa) and peak–valley height (Sy) values were evaluated by atomic force microscopy. The bacterial growth inhibition was evaluated using a disk diffusion test, and antimicrobial activity was determined with the plate microdilution method. The POBT showed no significant difference between sealers with and those without NPs in cervical and apical thirds (p > 0.05). In the middle third, the adhesion force was significant for Endosequence BC Sealer® (p < 0.05). The results showed that the Sa and Sy parameters, when AgNPs were added, did not show a statistically significant difference compared to the groups without nanoparticles (p > 0.05). All tested sealers showed bacterial growth inhibition, but no significant difference was found. Their efficacy, in descending order of antibacterial activity when AgNPs were added, is as follows: EndoSequence® BC SealerTM > Bio-C® Sealer > CeraSeal®. The incorporation of AgNPs into bioceramics improves antimicrobial activity without affecting mechanical properties.