HYHaoxi Ye

Haoxi Ye

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haoxi Ye has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Chaitanya Ss Duvvuri

    College of Optometry, University of Houston, Houston, TX 77204, USA

    1 shared publication
  • Chengjin Song

    Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan 528000, China

    1 shared publication
  • Gongpu Lan

    Guangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan 528000, China

    1 shared publication
  • Guoqin Ma

    School of Mechatronic Engineering and Automation, Foshan University, Foshan 528000, China

    1 shared publication
  • Jia Qin

    Guangdong Weiren Meditech Co., Ltd, Innovation and Entrepreneurship Teams Project of Guangdong Pearl River Talents Program, Foshan, China

    1 shared publication
  • Jing Cai

    Guangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan 528000, China

    1 shared publication

Latest Publications

  • Open Access

    Corneal Surface Wave Propagation Associated with Intraocular Pressures: OCT Elastography Assessment in a Simplified Eye Model

    by Guoqin Ma, Jing Cai, Rijian Zhong, Weichao He, Haoxi Ye, Chaitanya Duvvuri, Chengjin Song, Jinping Feng, Lin An, Jia Qin, et al.

    Assessing corneal biomechanics in vivo has long been a challenge in the field of ophthalmology. Despite recent advances in optical coherence tomography (OCT)-based elastography (OCE) methods, controversy remains regarding the effect of intraocular pressure (IOP) on mechanical wave propagation speed in the cornea. This could be attributed to the complexity of corneal biomechanics and the difficulties associated with conducting in vivo corneal shear-wave OCE measurements. We constructed a simplified artificial eye model with a silicone cornea and controllable IOPs and performed surface wave OCE measurements in radial directions (54–324°) of the silicone cornea at different IOP levels (10–40 mmHg). The results demonstrated increases in wave propagation speeds (mean ± STD) from 6.55 ± 0.09 m/s (10 mmHg) to 9.82 ± 0.19 m/s (40 mmHg), leading to an estimate of Young’s modulus, which increased from 145.23 ± 4.43 kPa to 326.44 ± 13.30 kPa. Our implementation of an artificial eye model highlighted that the impact of IOP on Young’s modulus (ΔE = 165.59 kPa, IOP: 10–40 mmHg) was more significant than the effect of stretching of the silicone cornea (ΔE = 15.79 kPa, relative elongation: 0.98–6.49%). Our study sheds light on the potential advantages of using an artificial eye model to represent the response of the human cornea during OCE measurement and provides valuable insights into the impact of IOP on wave-based OCE measurement for future in vivo corneal biomechanics studies.