Mingguan Zhao
Mingguan Zhao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Hongxia Wang
High Voltage Equipment Research Institute, State Grid Xinjiang Electric Power Co., Ltd., Electric Power Research Institute, Urumqi, 830013, China
2 shared publicationsMeng Li
High Voltage Equipment Research Institute, State Grid Xinjiang Electric Power Co., Ltd., Electric Power Research Institute, Urumqi, 830013, China
2 shared publicationsXinsheng Dong
High Voltage Equipment Research Institute, State Grid Xinjiang Electric Power Co., Ltd., Electric Power Research Institute, Urumqi, 830013, China
2 shared publicationsYang Yang
High Voltage Equipment Research Institute, State Grid Xinjiang Electric Power Co., Ltd., Electric Power Research Institute, Urumqi, 830013, China
2 shared publications- Yang Yang
Research Institute of Electric Power Science, State Grid Xinjiang Power Company Limited, Urumqi 830001, China
2 shared publications - Chunguang Li
School of Civil and Environmental Engineering, Changsha University of Science & Technology, Changsha, Hunan 410114, P. R. China
1 shared publication
Latest Publications
- Open Access
- 25 December 2025
- Published by MDPI AG in Atmosphere
- Vol. 17 (1) , 23
Ice Accretion Forecast for Power Grids Based on Pangu Model and Machine Learning Correction: A Case Study on Late December 2021 in Xinjiang, China
During late December 2021, an ice accretion disaster occurred in North Xinjiang, especially in the western part. It is found that the meteorological conditions suitable for the occurrence of ice accretion disasters are when the temperature is between −14 °C and −3 °C, the relative humidity is greater than 80%, the wind speed is between 4.5 m s−1 and 7.5 m s−1, and the pressure is between 919 hPa and 928 hPa. The ice accretion disaster is influenced by large-scale circulation, including the two-trough and one-ridge geopotential height structure in the middle troposphere and the spatially moving Ural Mountain blocking high pressure. Furthermore, using the artificial intelligence-based Pangu model and machine learning algorithms within the application of multiple linear regression and the leave-ten-out cross-validation, a skillful forecast correction model for ice accretion thickness in North Xinjiang is constructed. The prediction model has significant prediction skill for ice accretion thickness in North Xinjiang with 24 h, 48 h, and even 72 h in advance. The findings of the study can improve the timeliness of business system in the short-term and immediate forecast of ice accretion thickness, providing more reliable technical support for the ice prevention and disaster reduction of the power grids.
- 25 December 2025
- Published by MDPI AG in Atmosphere
- Vol. 17 (1) , 23
Open AccessIce Accretion Forecast for Power Grids Based on Pangu Model and Machine Learning Correction: A Case Study on Late December 2021 in Xinjiang, China
During late December 2021, an ice accretion disaster occurred in North Xinjiang, especially in the western part. It is found that the meteorological conditions suitable for the occurrence of ice accretion disasters are when the temperature is between −14 °C and −3 °C, the relative humidity is greater than 80%, the wind speed is between 4.5 m s−1 and 7.5 m s−1, and the pressure is between 919 hPa and 928 hPa. The ice accretion disaster is influenced by large-scale circulation, including the two-trough and one-ridge geopotential height structure in the middle troposphere and the spatially moving Ural Mountain blocking high pressure. Furthermore, using the artificial intelligence-based Pangu model and machine learning algorithms within the application of multiple linear regression and the leave-ten-out cross-validation, a skillful forecast correction model for ice accretion thickness in North Xinjiang is constructed. The prediction model has significant prediction skill for ice accretion thickness in North Xinjiang with 24 h, 48 h, and even 72 h in advance. The findings of the study can improve the timeliness of business system in the short-term and immediate forecast of ice accretion thickness, providing more reliable technical support for the ice prevention and disaster reduction of the power grids.
- Open Access
Galloping Performance of Transmission Line System Aeroelastic Model with Rime Through Wind-Tunnel Tests
This study presents an experimental investigation for the galloping performance of the transmission line system with rime under wind excitation. A full aeroelastic model wind-tunnel test is conducted to investigate the dynamic response of a two-bundled transmission line system with rime under different conditions. The time histories of the displacement of the conductor and the acceleration of the tower are measured in detail to analyze the characteristic of the wind-induced response. A comprehensive parametric experiment is performed to explore the effects of wind speed, wind direction, the number of conductor spans and the coupling between the conductor and the tower on the galloping performance of the transmission line system with rime. The results showed that the wind speed, wind direction and the number of conductor spans have significant influence on the galloping performance of conductor. The zero-degree wind direction is the most dangerous direction for the conductor. The multi-span conductor has different galloping initiation wind speed and vibration characteristics compared to the single-span conductor. The coupling effect between the conductor and the tower has trivial influence on the response of tower. This study uses 3D-printing models to simulate the aerodynamic shape of ice-covered wires with different thicknesses for wind-tunnel tests and obtains the influence of a series of parameters on the galloping vibration of transmission tower line systems.
Open AccessGalloping Performance of Transmission Line System Aeroelastic Model with Rime Through Wind-Tunnel Tests
This study presents an experimental investigation for the galloping performance of the transmission line system with rime under wind excitation. A full aeroelastic model wind-tunnel test is conducted to investigate the dynamic response of a two-bundled transmission line system with rime under different conditions. The time histories of the displacement of the conductor and the acceleration of the tower are measured in detail to analyze the characteristic of the wind-induced response. A comprehensive parametric experiment is performed to explore the effects of wind speed, wind direction, the number of conductor spans and the coupling between the conductor and the tower on the galloping performance of the transmission line system with rime. The results showed that the wind speed, wind direction and the number of conductor spans have significant influence on the galloping performance of conductor. The zero-degree wind direction is the most dangerous direction for the conductor. The multi-span conductor has different galloping initiation wind speed and vibration characteristics compared to the single-span conductor. The coupling effect between the conductor and the tower has trivial influence on the response of tower. This study uses 3D-printing models to simulate the aerodynamic shape of ice-covered wires with different thicknesses for wind-tunnel tests and obtains the influence of a series of parameters on the galloping vibration of transmission tower line systems.
- Open Access
- 1 January 2025
- Published by Tech Science Press in Computer Modeling in Engineering & Sciences
- Vol. 142 (2) , 2091-2109
A Dynamic Prediction Approach for Wire Icing Thickness under Extreme Weather Conditions Based on WGAN-GP-RTabNet
Ice cover on transmission lines is a significant issue that affects the safe operation of the power system. Accurate calculation of the thickness of wire icing can effectively prevent economic losses caused by ice disasters a... | Find, read and cite all the research you need on Tech Science Press
- 1 January 2025
- Published by Tech Science Press in Computer Modeling in Engineering & Sciences
- Vol. 142 (2) , 2091-2109
Open AccessA Dynamic Prediction Approach for Wire Icing Thickness under Extreme Weather Conditions Based on WGAN-GP-RTabNet
Ice cover on transmission lines is a significant issue that affects the safe operation of the power system. Accurate calculation of the thickness of wire icing can effectively prevent economic losses caused by ice disasters a... | Find, read and cite all the research you need on Tech Science Press
- 1 November 2024
- Published by SAGE Publications in Intelligent Decision Technologies
- Vol. 18 (4) , 3129-3142
Investigation of transmission line operation condition monitoring method based on firefly algorithm
With the explosive growth of electricity consumption, the demand for electricity by electricity users is increasing. As a core component of power supply, the safe and stable operation of transmission lines plays an important role in the normal operation of the entire power system. However, traditional monitoring methods for transmission line operation status face challenges such as limited accuracy, lack of real-time feedback, and high operational costs. In this paper, the Firefly algorithm is used to monitor the running status of transmission lines. Through synchronous testing with the traditional particle swarm optimization algorithm, it is found that the average accuracy of the Firefly algorithm in voltage and current measurement is improved to 93.13% and 93.66% respectively, which is better than the traditional algorithm. Firefly algorithm shows high precision in various power equipment monitoring, the average monitoring accuracy is 95.62% and 93.06%, respectively, which proves that it has stronger performance in transmission line monitoring and can achieve more stringent monitoring requirements. Through the comparison experiment of the algorithm, it proved that the Firefly algorithm had a strong performance in the transmission line operation status monitoring, and could more accurately identify the transmission line fault, which provided a new idea and new method for the safe operation status monitoring of transmission lines.
- 1 November 2024
- Published by SAGE Publications in Intelligent Decision Technologies
- Vol. 18 (4) , 3129-3142
Investigation of transmission line operation condition monitoring method based on firefly algorithm
With the explosive growth of electricity consumption, the demand for electricity by electricity users is increasing. As a core component of power supply, the safe and stable operation of transmission lines plays an important role in the normal operation of the entire power system. However, traditional monitoring methods for transmission line operation status face challenges such as limited accuracy, lack of real-time feedback, and high operational costs. In this paper, the Firefly algorithm is used to monitor the running status of transmission lines. Through synchronous testing with the traditional particle swarm optimization algorithm, it is found that the average accuracy of the Firefly algorithm in voltage and current measurement is improved to 93.13% and 93.66% respectively, which is better than the traditional algorithm. Firefly algorithm shows high precision in various power equipment monitoring, the average monitoring accuracy is 95.62% and 93.06%, respectively, which proves that it has stronger performance in transmission line monitoring and can achieve more stringent monitoring requirements. Through the comparison experiment of the algorithm, it proved that the Firefly algorithm had a strong performance in the transmission line operation status monitoring, and could more accurately identify the transmission line fault, which provided a new idea and new method for the safe operation status monitoring of transmission lines.
- Open Access
- 18 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4285
Study on the Bouncing Process Induced by Ice Shedding on Overhead Conductors under Strong Wind Conditions
Strong winds can lead to more complex ice shedding oscillation processes for overhead conductors, inducing flashovers, strand breakages and other accidents. This study analyzes the aerodynamic parameters of several typical icing features and establishes a numerical model for ice shedding on overhead conductors under strong wind conditions. The results show that for the same amount of icing, the resistance and lift force on the conductor changes with ice shape, wind attack angle and wind speed, which has a significant effect on the ice shedding jumping process. When the wind attack angle approaches 180°, the airflow resistance of the fan-shaped and D-shaped icing conductors significantly increases. And in the process of ice shedding response of transmission lines, the lateral amplitude may exceed 20 m, which increase the discharge risk of horizontally arranged conductors. Moreover, for the significant lateral oscillation of conductors by ice shedding under strong wind, the maximum horizontal displacement is approximately 1.6 times the difference in lateral position before and after ice shedding.
- 18 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4285
Open AccessStudy on the Bouncing Process Induced by Ice Shedding on Overhead Conductors under Strong Wind Conditions
Strong winds can lead to more complex ice shedding oscillation processes for overhead conductors, inducing flashovers, strand breakages and other accidents. This study analyzes the aerodynamic parameters of several typical icing features and establishes a numerical model for ice shedding on overhead conductors under strong wind conditions. The results show that for the same amount of icing, the resistance and lift force on the conductor changes with ice shape, wind attack angle and wind speed, which has a significant effect on the ice shedding jumping process. When the wind attack angle approaches 180°, the airflow resistance of the fan-shaped and D-shaped icing conductors significantly increases. And in the process of ice shedding response of transmission lines, the lateral amplitude may exceed 20 m, which increase the discharge risk of horizontally arranged conductors. Moreover, for the significant lateral oscillation of conductors by ice shedding under strong wind, the maximum horizontal displacement is approximately 1.6 times the difference in lateral position before and after ice shedding.
- Open Access
Study on the Dynamic Characteristics of Tensional Force for Ice Accumulated Overhead Lines Considering Instantaneous Wind Speed
Icing is one of the key factors affecting the security and reliability of power system operation. Ice accumulation on the overhead line (OHL) conductors is often accompanied by strong winds, whose magnitude and direction are varied constantly, which imposes challenges to the on-line monitoring of OHL’s ice load. This paper analyzed the dynamic characteristics of the tensional force for ice accumulated OHLs through both the on-site experiment and the finite element method (FEM). The correlation between the instantaneous wind speed, the thickness of the accumulated ice and the dynamic tensional force, the aerodynamic resistance coefficient of the conductor, is investigated. It is found that the axial dynamic tension at the end of the iced conductor is approximately proportional to the square of the instantaneous wind speed. The higher the wind speed, the larger the difference between the static tension and the maximum dynamic tension calculated using the 10-min average wind speed. Under the conditions of the example in this article (crescent-shaped icing), when the average wind speed is 20 m/s, the ratio of the difference to static tension is 11.19%. These conclusions are verified with the computational fluid dynamic (CFD) simulation, the same correlation is identified in comparison with the experiments. Due to the fact that the magnitudes of tensional force and vibration are determined by the instantaneous wind speed, significant error exists within traditional calculation methods where average wind speed is used instead.
Open AccessStudy on the Dynamic Characteristics of Tensional Force for Ice Accumulated Overhead Lines Considering Instantaneous Wind Speed
Icing is one of the key factors affecting the security and reliability of power system operation. Ice accumulation on the overhead line (OHL) conductors is often accompanied by strong winds, whose magnitude and direction are varied constantly, which imposes challenges to the on-line monitoring of OHL’s ice load. This paper analyzed the dynamic characteristics of the tensional force for ice accumulated OHLs through both the on-site experiment and the finite element method (FEM). The correlation between the instantaneous wind speed, the thickness of the accumulated ice and the dynamic tensional force, the aerodynamic resistance coefficient of the conductor, is investigated. It is found that the axial dynamic tension at the end of the iced conductor is approximately proportional to the square of the instantaneous wind speed. The higher the wind speed, the larger the difference between the static tension and the maximum dynamic tension calculated using the 10-min average wind speed. Under the conditions of the example in this article (crescent-shaped icing), when the average wind speed is 20 m/s, the ratio of the difference to static tension is 11.19%. These conclusions are verified with the computational fluid dynamic (CFD) simulation, the same correlation is identified in comparison with the experiments. Due to the fact that the magnitudes of tensional force and vibration are determined by the instantaneous wind speed, significant error exists within traditional calculation methods where average wind speed is used instead.