Cheng Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cheng Jin has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Kangli Liu
School of Electrical Engineering, Southeast University, Nanjing, China
11 shared publications - Jianfeng Zhao
School of Electrical Engineering, Southeast University, Nanjing 210096, China
10 shared publications - Jingyang Zhou
School of Electrical Engineering, Southeast University, Nanjing, China
3 shared publications - Zhendong Ji
Nanjing University of Science and Technology
3 shared publications - Hongqi Ding
School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing, China
2 shared publications Peng Chen
School of Electrical Engineering, Southeast University, Nanjing, China
2 shared publications
Latest Publications
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (4) , 498-502
Accurate Threshold Voltage Prediction Control for Charge-Controlled LLC Converters in Two-Stage Single-Phase Rectifiers
This brief proposes an accurate threshold voltage prediction control (ATVPC) strategy for charge-controlled LLC converters in two-stage single-phase rectifiers, addressing the challenges of second-harmonic output voltage ripple and limited dynamic response. The proposed method solves precise control signal instead of relying on a slow PI controller for error compensation, which are commonly required in existing state-plane feedforward control schemes. Consequently, the proposed strategy overcomes the bandwidth limitation imposed by slow linear compensators. Simulation and experimental results verify its dynamic enhancement and robust ripple rejection capability.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (4) , 498-502
Accurate Threshold Voltage Prediction Control for Charge-Controlled LLC Converters in Two-Stage Single-Phase Rectifiers
This brief proposes an accurate threshold voltage prediction control (ATVPC) strategy for charge-controlled LLC converters in two-stage single-phase rectifiers, addressing the challenges of second-harmonic output voltage ripple and limited dynamic response. The proposed method solves precise control signal instead of relying on a slow PI controller for error compensation, which are commonly required in existing state-plane feedforward control schemes. Consequently, the proposed strategy overcomes the bandwidth limitation imposed by slow linear compensators. Simulation and experimental results verify its dynamic enhancement and robust ripple rejection capability.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (3) , 3775-3798
Artificial Intelligence-Based Open-Circuit Fault Diagnosis for Power Electronic Converters: Recent Advances and Future Prospects
Fault localization and identification for converters are related to the stable operation of power electronic-based systems and are receiving widespread attention. Advanced algorithms, represented by artificial intelligence (AI), are providing new solutions. This article explores the application of AI in diagnosing open-circuit faults in power electronic converters, which are critical components of modern power systems. The fault diagnosis techniques are systematically categorized and summarized from an algorithmic perspective, covering a range of methods including traditional machine learning (e.g., support vector machine and extreme learning machine), neural networks (e.g., convolutional neural network and recurrent neural network), multimodal fusion, and hybrid models. Their performance is evaluated in terms of noise robustness, computational efficiency, and real-time capabilities. Finally, future prospects and recommended directions for AI-driven fault diagnosis are provided, advocating for innovations to enhance the reliability and cost-effectiveness of power converter systems. This review aims to provide a comprehensive reference, fostering the development of advanced diagnostic algorithms and techniques.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (3) , 3775-3798
Artificial Intelligence-Based Open-Circuit Fault Diagnosis for Power Electronic Converters: Recent Advances and Future Prospects
Fault localization and identification for converters are related to the stable operation of power electronic-based systems and are receiving widespread attention. Advanced algorithms, represented by artificial intelligence (AI), are providing new solutions. This article explores the application of AI in diagnosing open-circuit faults in power electronic converters, which are critical components of modern power systems. The fault diagnosis techniques are systematically categorized and summarized from an algorithmic perspective, covering a range of methods including traditional machine learning (e.g., support vector machine and extreme learning machine), neural networks (e.g., convolutional neural network and recurrent neural network), multimodal fusion, and hybrid models. Their performance is evaluated in terms of noise robustness, computational efficiency, and real-time capabilities. Finally, future prospects and recommended directions for AI-driven fault diagnosis are provided, advocating for innovations to enhance the reliability and cost-effectiveness of power converter systems. This review aims to provide a comprehensive reference, fostering the development of advanced diagnostic algorithms and techniques.
- Open Access
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 6, 1428-1437
Differentiated-Gain-Regulation-Based Current Balancing Control for Multi-Phase Interleaved LLC Resonant Converters
In multiphase LLC resonant converters, the component parameter tolerance of the resonant tanks will lead to discrepancies in voltage gain, resulting in imbalance output current. In this paper, the principle and mechanism of current imbalance among multiphase LLC resonant converters is discussed through state plane analysis. Based on the limitation analysis for the switch-controlled capacitor and phase shift modulation, an improved differentiated-gain-regulation (DGR)-based current balancing strategy is proposed by adding external circuits to compensate for parameter difference, assisted with voltage regulating method. The essential principle is to initially increase the gains of light loaded phases with switch-controlled capacitor. And for phases with heavy loads, the phase shift modulation is used for suppressing gains to avoid control instability caused by the introduction of switch-controlled capacitor. It would not affect the soft switching characteristics of LLC resonant converters. Finally, the hardware-in-the-loop based experiment results verify the correctness and effectiveness of the proposed method and analysis.
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 6, 1428-1437
Open AccessDifferentiated-Gain-Regulation-Based Current Balancing Control for Multi-Phase Interleaved LLC Resonant Converters
In multiphase LLC resonant converters, the component parameter tolerance of the resonant tanks will lead to discrepancies in voltage gain, resulting in imbalance output current. In this paper, the principle and mechanism of current imbalance among multiphase LLC resonant converters is discussed through state plane analysis. Based on the limitation analysis for the switch-controlled capacitor and phase shift modulation, an improved differentiated-gain-regulation (DGR)-based current balancing strategy is proposed by adding external circuits to compensate for parameter difference, assisted with voltage regulating method. The essential principle is to initially increase the gains of light loaded phases with switch-controlled capacitor. And for phases with heavy loads, the phase shift modulation is used for suppressing gains to avoid control instability caused by the introduction of switch-controlled capacitor. It would not affect the soft switching characteristics of LLC resonant converters. Finally, the hardware-in-the-loop based experiment results verify the correctness and effectiveness of the proposed method and analysis.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 72 (10) , 1453-1457
Enhanced Small-Signal Model for Charge-Controlled LLC Resonant Converters Using Time-Domain Analysis
The conventional models employ fundamental harmonic approximation for charge-controlled LLC resonant converter. However, when the switching frequency deviates from the resonant frequency, significant distortion occurs in the state variables, leading to degraded accuracy in the models. To address this issue, this brief proposes a novel small-signal modeling approach based on time-domain analysis. The proposed method first derives the simplified time-domain operating constraints for the converter. The simplified constraints relieve the computation burden and reduce the number of intermediate variables, making it more suitable for small-signal modeling. Next, the relationships between small-signal variables are derived from these constraints. Finally, a complete mathematical model of the charge-controlled LLC resonant converter is constructed. Experimental validation is performed on a 200V/1kW LLC resonant converter prototype. Both simulation and experimental results confirm the superior accuracy of the proposed model.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 72 (10) , 1453-1457
Enhanced Small-Signal Model for Charge-Controlled LLC Resonant Converters Using Time-Domain Analysis
The conventional models employ fundamental harmonic approximation for charge-controlled LLC resonant converter. However, when the switching frequency deviates from the resonant frequency, significant distortion occurs in the state variables, leading to degraded accuracy in the models. To address this issue, this brief proposes a novel small-signal modeling approach based on time-domain analysis. The proposed method first derives the simplified time-domain operating constraints for the converter. The simplified constraints relieve the computation burden and reduce the number of intermediate variables, making it more suitable for small-signal modeling. Next, the relationships between small-signal variables are derived from these constraints. Finally, a complete mathematical model of the charge-controlled LLC resonant converter is constructed. Experimental validation is performed on a 200V/1kW LLC resonant converter prototype. Both simulation and experimental results confirm the superior accuracy of the proposed model.
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (11) , 16790-16808
A Hierarchical Multiarea Hybrid Equivalent for Efficient Simulation of Scalable Power Electronics Systems
This article proposes a hierarchical multiarea hybrid equivalent circuit partitioning framework for electromagnetic transient simulations of large-scale power electronics systems in the time domain. The concepts of linking partition and hierarchical partition tree are introduced to organize this partitioning process. The multiarea hybrid equivalent (MAHE) is applied hierarchically across multiple levels of the partition tree, leveraging the linear additivity of impedance in series and admittance in parallel. This method solves series currents and parallel voltages layer by layer, transferring Thévenin and Norton equivalents from lower to upper ports to mitigate the increase in linking variables connecting circuit partitions. The proposed hourglass scheduling model also optimizes the execution order by grouping independent partitions in batches, enhancing parallelism. Simulation models for a two-terminal modular multilevel converter based high voltage direct current transmission system and a photovoltaic power station are developed and compared with other commercial simulation software in terms of accuracy and efficiency. The hierarchical MAHE scheme demonstrates equivalent accuracy while offering superior efficiency.
- 4 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (11) , 16790-16808
A Hierarchical Multiarea Hybrid Equivalent for Efficient Simulation of Scalable Power Electronics Systems
This article proposes a hierarchical multiarea hybrid equivalent circuit partitioning framework for electromagnetic transient simulations of large-scale power electronics systems in the time domain. The concepts of linking partition and hierarchical partition tree are introduced to organize this partitioning process. The multiarea hybrid equivalent (MAHE) is applied hierarchically across multiple levels of the partition tree, leveraging the linear additivity of impedance in series and admittance in parallel. This method solves series currents and parallel voltages layer by layer, transferring Thévenin and Norton equivalents from lower to upper ports to mitigate the increase in linking variables connecting circuit partitions. The proposed hourglass scheduling model also optimizes the execution order by grouping independent partitions in batches, enhancing parallelism. Simulation models for a two-terminal modular multilevel converter based high voltage direct current transmission system and a photovoltaic power station are developed and compared with other commercial simulation software in terms of accuracy and efficiency. The hierarchical MAHE scheme demonstrates equivalent accuracy while offering superior efficiency.
- 3 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 608-616
Arc Extinction and Control Strategy for Hybrid Grounding System Considering Line Impedance and Load in 10 kV Distribution Networks
Hybrid grounding system (HGS) combining neutral-point voltage regulator and low-resistance has demonstrated its application potential. However, when the line impedance and load cannot be ignored, the entire control strategy may be significantly affected, thereby influencing the arc extinction effect. To improve the security and reliability of distribution networks when addressing single-phase ground faults, this paper presents a complete control strategy for HGS. Firstly, the study begins by introducing the structure of HGS and conventional arc extinction principle. And then, considering the impact of line impedance and load, an improved arc extinction strategy involving calculating accurate reference voltage of the converter is further proposed. In addition, to achieve precise tracking of the reference voltage, a dual-loop control strategy is employed, with the addition of a lead correction stage to enhance the system stability. And a coordinated control strategy for HGS is proposed, which can deal with all types of single-phase ground faults by setting three-level thresholds for zero-sequence current. Finally, sufficient results based on simulation, hardware-in-the-loop and 10kV hardware testing platform validated the effectiveness of the proposed method.
- 3 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 608-616
Arc Extinction and Control Strategy for Hybrid Grounding System Considering Line Impedance and Load in 10 kV Distribution Networks
Hybrid grounding system (HGS) combining neutral-point voltage regulator and low-resistance has demonstrated its application potential. However, when the line impedance and load cannot be ignored, the entire control strategy may be significantly affected, thereby influencing the arc extinction effect. To improve the security and reliability of distribution networks when addressing single-phase ground faults, this paper presents a complete control strategy for HGS. Firstly, the study begins by introducing the structure of HGS and conventional arc extinction principle. And then, considering the impact of line impedance and load, an improved arc extinction strategy involving calculating accurate reference voltage of the converter is further proposed. In addition, to achieve precise tracking of the reference voltage, a dual-loop control strategy is employed, with the addition of a lead correction stage to enhance the system stability. And a coordinated control strategy for HGS is proposed, which can deal with all types of single-phase ground faults by setting three-level thresholds for zero-sequence current. Finally, sufficient results based on simulation, hardware-in-the-loop and 10kV hardware testing platform validated the effectiveness of the proposed method.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Open-Circuit Fault Diagnosis and Analysis for Integrated Charging System Based on Bidirectional Gated Recurrent Unit and Attention Mechanism
Due to the widespread adoption of electric vehicles, integrated charging stations have been increasingly applied. However, because of the extensive number of components, when a fault occurs, how to identify the faulty components is a great challenge. In this paper, considering the power conversion system of integrated charging stations, the impact of internal open-circuit faults in IGBTs and capacitors, along with fault identification methods, are discussed. By combining signal processing and deep learning for fault localization, the neural network model based on the bidirectional gated recurrent unit (Bi-GRU) and attention mechanism is proposed, which can flexibly learn crucial information, enhance the perception of important segments in sequences, and achieve higher accuracy in open-circuit fault identification. Through comparative analysis for the validation set among different models, the effectiveness and advantages of the proposed model and analysis are proved. The proposed method has good versatility and can be used for fault identification and operation reliability improvement for other power electronics-based systems.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Open-Circuit Fault Diagnosis and Analysis for Integrated Charging System Based on Bidirectional Gated Recurrent Unit and Attention Mechanism
Due to the widespread adoption of electric vehicles, integrated charging stations have been increasingly applied. However, because of the extensive number of components, when a fault occurs, how to identify the faulty components is a great challenge. In this paper, considering the power conversion system of integrated charging stations, the impact of internal open-circuit faults in IGBTs and capacitors, along with fault identification methods, are discussed. By combining signal processing and deep learning for fault localization, the neural network model based on the bidirectional gated recurrent unit (Bi-GRU) and attention mechanism is proposed, which can flexibly learn crucial information, enhance the perception of important segments in sequences, and achieve higher accuracy in open-circuit fault identification. Through comparative analysis for the validation set among different models, the effectiveness and advantages of the proposed model and analysis are proved. The proposed method has good versatility and can be used for fault identification and operation reliability improvement for other power electronics-based systems.
- 26 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 5 (2) , 425-436
Boundaries Extension of Stability Region and z-Domain Controller Implementation for Grid-Forming Converters
Grid-forming (GFM) converters can support system voltage and frequency, which promotes the integration between distributed generations and power grid. Due to the time delay of digital control, the virtual impedance exhibits opposite damping characteristics on both sides of 1/6 of the sampling frequency ( fs /6). The stable operation of GFM converters can be achieved by setting a reasonable damping feedback coefficient in each separate frequency interval. However, the load or line impedance variation may cause the resonant frequency of LC filter to cross the frequency boundary, so GFM converters will not be stable when the resonant frequency is near the frequency boundary. In this paper, an improved active damping control with a lead compensator is proposed to achieve positive damping from 0 to fs /4, which eliminates the instability resonant frequency region, and the stability of GFM converters is significantly improved. Then, the procedures of parameter tuning for obtaining the maximum system damping is presented. Furthermore, the discrete-time domain resonant controller is proposed to acquire a high-performance voltage control, which brings a fast transient response without overshoot for output voltage. Finally, experimental results verify the effectiveness of the analysis.
- 26 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 5 (2) , 425-436
Boundaries Extension of Stability Region and z-Domain Controller Implementation for Grid-Forming Converters
Grid-forming (GFM) converters can support system voltage and frequency, which promotes the integration between distributed generations and power grid. Due to the time delay of digital control, the virtual impedance exhibits opposite damping characteristics on both sides of 1/6 of the sampling frequency ( fs /6). The stable operation of GFM converters can be achieved by setting a reasonable damping feedback coefficient in each separate frequency interval. However, the load or line impedance variation may cause the resonant frequency of LC filter to cross the frequency boundary, so GFM converters will not be stable when the resonant frequency is near the frequency boundary. In this paper, an improved active damping control with a lead compensator is proposed to achieve positive damping from 0 to fs /4, which eliminates the instability resonant frequency region, and the stability of GFM converters is significantly improved. Then, the procedures of parameter tuning for obtaining the maximum system damping is presented. Furthermore, the discrete-time domain resonant controller is proposed to acquire a high-performance voltage control, which brings a fast transient response without overshoot for output voltage. Finally, experimental results verify the effectiveness of the analysis.
- 5 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (10) , 12331-12336
Multiarea Hybrid Equivalent for Power Electronics System
This letter proposes the multiarea hybrid equivalent (MAHE) circuit partition scheme, which decouples interconnected power electronics blocks of series, parallel, and both into smaller independent subcircuits, overcoming the limitation of low efficiency in the intricate network of blocks. The MAHE scheme segregates each partition's series and parallel section apart from the internal section, then turns the series section into impedance and the parallel section into admittance. The proposed scheme is based on principles of impedance's additivity and Kirchhoff's voltage law in series, and admittance's additivity and Kirchhoff's current law in parallel, promoting the relationship of partitions from one-to-one to many-to-many and simplifying the calculation of interconnections. The input parallel and output series (IPOS) converter illustrates the scheme's principle and effectiveness. In simulations of the IPOS converter, MAHE achieves efficient speed-ups compared with commercial simulation softwares.
- 5 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (10) , 12331-12336
Multiarea Hybrid Equivalent for Power Electronics System
This letter proposes the multiarea hybrid equivalent (MAHE) circuit partition scheme, which decouples interconnected power electronics blocks of series, parallel, and both into smaller independent subcircuits, overcoming the limitation of low efficiency in the intricate network of blocks. The MAHE scheme segregates each partition's series and parallel section apart from the internal section, then turns the series section into impedance and the parallel section into admittance. The proposed scheme is based on principles of impedance's additivity and Kirchhoff's voltage law in series, and admittance's additivity and Kirchhoff's current law in parallel, promoting the relationship of partitions from one-to-one to many-to-many and simplifying the calculation of interconnections. The input parallel and output series (IPOS) converter illustrates the scheme's principle and effectiveness. In simulations of the IPOS converter, MAHE achieves efficient speed-ups compared with commercial simulation softwares.
- 20 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (8) , 9755-9766
A Region-Folding Electromagnetic Transient Simulation Approach for Large-Scale Power Electronics System
This article proposes a region-folding electromagnetic transient simulation approach for large-scale power electronics systems to boost simulation speed. In the region-folding approach, the loop tear method is proposed to decouple the connections among power electronics blocks, the grouping and pre-calculating method of identical structural blocks is proposed to avoid computing the inverse of matrices repeatedly, and the global simultaneous response procedure is proposed to handle the simultaneous and multiple switching events. The implementation of the proposed approach is combined with high-performance parallelization technology to shorten the simulation time. The modular multilevel converter based high voltage direct current model and dc photovoltaic power station model are simulated respectively to validate the accuracy and efficiency. Simulation results indicate that the proposed approach has the same accuracy as other electromagnetic transients commercial software with better efficiency.
- 20 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (8) , 9755-9766
A Region-Folding Electromagnetic Transient Simulation Approach for Large-Scale Power Electronics System
This article proposes a region-folding electromagnetic transient simulation approach for large-scale power electronics systems to boost simulation speed. In the region-folding approach, the loop tear method is proposed to decouple the connections among power electronics blocks, the grouping and pre-calculating method of identical structural blocks is proposed to avoid computing the inverse of matrices repeatedly, and the global simultaneous response procedure is proposed to handle the simultaneous and multiple switching events. The implementation of the proposed approach is combined with high-performance parallelization technology to shorten the simulation time. The modular multilevel converter based high voltage direct current model and dc photovoltaic power station model are simulated respectively to validate the accuracy and efficiency. Simulation results indicate that the proposed approach has the same accuracy as other electromagnetic transients commercial software with better efficiency.