Hongqi Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hongqi Ding has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Fujun Ma
College of Electrical and Information Engineering, Hunan University, Changsha, China
4 shared publications - Lei Wang
Beijing Jiaotong University
3 shared publications - Rong Han
School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology 1 , Dalian 116024
3 shared publications - Cheng Jin
School of Electrical Engineering, Southeast University, Nanjing, China
2 shared publications - Gelin Huang
College of Electrical and Information Engineering, Hunan University, Changsha, China
2 shared publications - Jianfeng Zhao
School of Electrical Engineering, Southeast University, Nanjing 210096, China
2 shared publications
Latest Publications
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (4) , 498-502
Accurate Threshold Voltage Prediction Control for Charge-Controlled LLC Converters in Two-Stage Single-Phase Rectifiers
This brief proposes an accurate threshold voltage prediction control (ATVPC) strategy for charge-controlled LLC converters in two-stage single-phase rectifiers, addressing the challenges of second-harmonic output voltage ripple and limited dynamic response. The proposed method solves precise control signal instead of relying on a slow PI controller for error compensation, which are commonly required in existing state-plane feedforward control schemes. Consequently, the proposed strategy overcomes the bandwidth limitation imposed by slow linear compensators. Simulation and experimental results verify its dynamic enhancement and robust ripple rejection capability.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (4) , 498-502
Accurate Threshold Voltage Prediction Control for Charge-Controlled LLC Converters in Two-Stage Single-Phase Rectifiers
This brief proposes an accurate threshold voltage prediction control (ATVPC) strategy for charge-controlled LLC converters in two-stage single-phase rectifiers, addressing the challenges of second-harmonic output voltage ripple and limited dynamic response. The proposed method solves precise control signal instead of relying on a slow PI controller for error compensation, which are commonly required in existing state-plane feedforward control schemes. Consequently, the proposed strategy overcomes the bandwidth limitation imposed by slow linear compensators. Simulation and experimental results verify its dynamic enhancement and robust ripple rejection capability.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 72 (10) , 1453-1457
Enhanced Small-Signal Model for Charge-Controlled LLC Resonant Converters Using Time-Domain Analysis
The conventional models employ fundamental harmonic approximation for charge-controlled LLC resonant converter. However, when the switching frequency deviates from the resonant frequency, significant distortion occurs in the state variables, leading to degraded accuracy in the models. To address this issue, this brief proposes a novel small-signal modeling approach based on time-domain analysis. The proposed method first derives the simplified time-domain operating constraints for the converter. The simplified constraints relieve the computation burden and reduce the number of intermediate variables, making it more suitable for small-signal modeling. Next, the relationships between small-signal variables are derived from these constraints. Finally, a complete mathematical model of the charge-controlled LLC resonant converter is constructed. Experimental validation is performed on a 200V/1kW LLC resonant converter prototype. Both simulation and experimental results confirm the superior accuracy of the proposed model.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 72 (10) , 1453-1457
Enhanced Small-Signal Model for Charge-Controlled LLC Resonant Converters Using Time-Domain Analysis
The conventional models employ fundamental harmonic approximation for charge-controlled LLC resonant converter. However, when the switching frequency deviates from the resonant frequency, significant distortion occurs in the state variables, leading to degraded accuracy in the models. To address this issue, this brief proposes a novel small-signal modeling approach based on time-domain analysis. The proposed method first derives the simplified time-domain operating constraints for the converter. The simplified constraints relieve the computation burden and reduce the number of intermediate variables, making it more suitable for small-signal modeling. Next, the relationships between small-signal variables are derived from these constraints. Finally, a complete mathematical model of the charge-controlled LLC resonant converter is constructed. Experimental validation is performed on a 200V/1kW LLC resonant converter prototype. Both simulation and experimental results confirm the superior accuracy of the proposed model.
- 19 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (3) , 1749-1760
Dual Fundamental Frequency HSS-Based Reduced Order Impedance Modeling of AC/AC Modular Multilevel Converter for Tundish Heating
Due to the specificity of continuous casting production, the application of ac/ac MMC structure in induction heating power supply requires the realization of frequency conversion from grid AC to low and medium single-phase AC, which makes the conventional modeling methods inappropriate. In this article, an HSS-based reduced order impedance model is proposed. Firstly, due to the complexity of the internal harmonics, the harmonic attenuation of the internal signals is calculated quantitatively by analyzing the three-dimensional signal-flow graph and then the harmonic frequencies are truncated, which provide a basis for model simplification. Furthermore, to precisely describe the amplitude-phase characteristics of the ac/ac MMC under different output frequencies, the harmonic state space modeling method is improved by combining the double Fourier integral transform. Finally, the correctness of the frequency analysis and the accuracy of the reduced order model are verified.
- 19 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (3) , 1749-1760
Dual Fundamental Frequency HSS-Based Reduced Order Impedance Modeling of AC/AC Modular Multilevel Converter for Tundish Heating
Due to the specificity of continuous casting production, the application of ac/ac MMC structure in induction heating power supply requires the realization of frequency conversion from grid AC to low and medium single-phase AC, which makes the conventional modeling methods inappropriate. In this article, an HSS-based reduced order impedance model is proposed. Firstly, due to the complexity of the internal harmonics, the harmonic attenuation of the internal signals is calculated quantitatively by analyzing the three-dimensional signal-flow graph and then the harmonic frequencies are truncated, which provide a basis for model simplification. Furthermore, to precisely describe the amplitude-phase characteristics of the ac/ac MMC under different output frequencies, the harmonic state space modeling method is improved by combining the double Fourier integral transform. Finally, the correctness of the frequency analysis and the accuracy of the reduced order model are verified.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (9) , 10716-10726
An Internal Thermal Distribution Balance Control Between the Top and Bottom Devices in Modular Multilevel Converter
The reliability of semiconductor devices directly determines the safe operation of the system. However, temperature is one of the key factors that affect the reliability of semiconductors. Since the dc component of arm current in modular multilevel converter results in the unbalanced thermal stress between the top and bottom devices in the submodule (SM), which causes the discrepancy in the lifetime of four devices inside the SM, and seriously threatens the reliability of the system. To solve this problem, an internal thermal distribution balance control between top and bottom devices is proposed in this article. The proposed control method has the advantage of reducing the junction temperature deviation between the top and bottom devices without affecting the electrical characteristics of the ac and dc ports. Moreover, the voltage stress of all devices is reduced especially for active power transfer, which alleviates the risk of overvoltage failure. The SM lifetime under the proposed control is increased by 14.2% based on full-scale simulation. Finally, a downscale experimental platform is built to verify the effectiveness of the proposed control method.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (9) , 10716-10726
An Internal Thermal Distribution Balance Control Between the Top and Bottom Devices in Modular Multilevel Converter
The reliability of semiconductor devices directly determines the safe operation of the system. However, temperature is one of the key factors that affect the reliability of semiconductors. Since the dc component of arm current in modular multilevel converter results in the unbalanced thermal stress between the top and bottom devices in the submodule (SM), which causes the discrepancy in the lifetime of four devices inside the SM, and seriously threatens the reliability of the system. To solve this problem, an internal thermal distribution balance control between top and bottom devices is proposed in this article. The proposed control method has the advantage of reducing the junction temperature deviation between the top and bottom devices without affecting the electrical characteristics of the ac and dc ports. Moreover, the voltage stress of all devices is reduced especially for active power transfer, which alleviates the risk of overvoltage failure. The SM lifetime under the proposed control is increased by 14.2% based on full-scale simulation. Finally, a downscale experimental platform is built to verify the effectiveness of the proposed control method.
- 2 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2063-2075
Loss-Balancing Control Strategy for Single-Phase MMC With Asymmetric Phase Leg Structure
Submodule (SM) failures are a common fault type in MMCs, and SM symmetrical bypass guarantees the uninterrupted operation of the system. However, the number of SMs between the phase legs is not equal after bypass, which results in a deviation in the capacitor voltage. In this condition, the SM loss difference between phase legs is large, and the reliable operation of the MMC is highly threatened. To address this problem, a loss-balancing control strategy is proposed in this paper based on an asymmetric phase leg structure. Specifically, the currents of two-phase legs are improved by injecting fundamental frequency components in the proposed control strategy. In addition, the voltage stress of the device is relieved by adjusting the number of equivalent SMs. On this basis, the minimization of the average SM loss deviation between phase legs is taken as the objective function, where the solution for injecting the fundamental frequency components and the number of equivalent SMs is obtained by iterative optimization. Finally, simulation analysis and experimental results are provided to verify the effectiveness of the proposed control strategy.
- 2 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2063-2075
Loss-Balancing Control Strategy for Single-Phase MMC With Asymmetric Phase Leg Structure
Submodule (SM) failures are a common fault type in MMCs, and SM symmetrical bypass guarantees the uninterrupted operation of the system. However, the number of SMs between the phase legs is not equal after bypass, which results in a deviation in the capacitor voltage. In this condition, the SM loss difference between phase legs is large, and the reliable operation of the MMC is highly threatened. To address this problem, a loss-balancing control strategy is proposed in this paper based on an asymmetric phase leg structure. Specifically, the currents of two-phase legs are improved by injecting fundamental frequency components in the proposed control strategy. In addition, the voltage stress of the device is relieved by adjusting the number of equivalent SMs. On this basis, the minimization of the average SM loss deviation between phase legs is taken as the objective function, where the solution for injecting the fundamental frequency components and the number of equivalent SMs is obtained by iterative optimization. Finally, simulation analysis and experimental results are provided to verify the effectiveness of the proposed control strategy.
- 14 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (1) , 2220-2234
Fault-Tolerant Method of Modular Railway Power Conditioner Based on DC Bus Voltage Regulation
With the development of high-speed electrified railway, many serious power quality problems have arisen and caused widespread concern. In order to achieve comprehensive management of power quality, modular railway power conditioner (MRPC) has been applied to traction systems. However, due to the presence of multiple sub-modules (SMs). The reliability of the equipment is threatened as the number of SMs increases. In medium-voltage applications, system reliability can be improved by adding redundant SMs. However, when the redundant SMs are run out, the reliability of the whole system cannot be guaranteed. Therefore, a fault-tolerant method based on DC bus voltage regulation is proposed to improve the reliability of MRPC by modulation signal reconstruction. The proposed method not only achieves fault ride-through to maintain normal operation and improves the SMs voltage stress on the opposite converter, but also effectively improves the over-modulation. The effectiveness of the proposed method is verified by down-scale experiments.
- 14 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (1) , 2220-2234
Fault-Tolerant Method of Modular Railway Power Conditioner Based on DC Bus Voltage Regulation
With the development of high-speed electrified railway, many serious power quality problems have arisen and caused widespread concern. In order to achieve comprehensive management of power quality, modular railway power conditioner (MRPC) has been applied to traction systems. However, due to the presence of multiple sub-modules (SMs). The reliability of the equipment is threatened as the number of SMs increases. In medium-voltage applications, system reliability can be improved by adding redundant SMs. However, when the redundant SMs are run out, the reliability of the whole system cannot be guaranteed. Therefore, a fault-tolerant method based on DC bus voltage regulation is proposed to improve the reliability of MRPC by modulation signal reconstruction. The proposed method not only achieves fault ride-through to maintain normal operation and improves the SMs voltage stress on the opposite converter, but also effectively improves the over-modulation. The effectiveness of the proposed method is verified by down-scale experiments.