Andrea Querol
Research Subjects
Research Interests
Andrea Querol has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Sergio Gallardo
Universitat Politècnica de València
13 shared publications - Jose Rodenas
Departamento de Ingenieria Quimica y Nuclear, Universidad Politecnica de Valencia, Valencia, Spain
7 shared publications Fausto Pozuelo
3 shared publicationsG. Verdu
Ingeniería Química y Nuclear department, Universitat Politècnica de València, 46022 Spain
3 shared publicationsG. Verdú
3 shared publications- Gumersindo Verdu
Polytechnic University of Valencia
3 shared publications
Latest Publications
- Open Access
- 30 November 2022
- Published by Atena Editora Edição de Livros Ltda in International Journal of Human Sciences Research
- Vol. 2 (37) , 2-10
EVALUACIÓN DE COMPETENCIAS TRANSVERSALES A TRAVÉS DEL APRENDIZAJE BASADO EN RETOS
This work focuses on the methodology used in the Mechanical Engineering Degree of Florida Universitària to evaluate the transversal competences through Challenge-Based Learning (CBL). Students of the first, second and third courses of the Mechanical Engineering Degree divided in groups, develop a project which implies a challenge or problem related to their environment. During the different courses students must develop different tasks related to all the subjects. As results, some challenges conducted by the students are shown and through the global assessment of IP, by the students, the suitability of this methodology is obtained.
- 30 November 2022
- Published by Atena Editora Edição de Livros Ltda in International Journal of Human Sciences Research
- Vol. 2 (37) , 2-10
Open AccessEVALUACIÓN DE COMPETENCIAS TRANSVERSALES A TRAVÉS DEL APRENDIZAJE BASADO EN RETOS
This work focuses on the methodology used in the Mechanical Engineering Degree of Florida Universitària to evaluate the transversal competences through Challenge-Based Learning (CBL). Students of the first, second and third courses of the Mechanical Engineering Degree divided in groups, develop a project which implies a challenge or problem related to their environment. During the different courses students must develop different tasks related to all the subjects. As results, some challenges conducted by the students are shown and through the global assessment of IP, by the students, the suitability of this methodology is obtained.
- 1 November 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 116, 214-218
Uncertainty analysis in environmental radioactivity measurements using the Monte Carlo code MCNP5
- 1 November 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 116, 214-218
Uncertainty analysis in environmental radioactivity measurements using the Monte Carlo code MCNP5
- 1 November 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 116, 219-225
Using lattice tools and unfolding methods for hpge detector efficiency simulation with the Monte Carlo code MCNP5
- 1 November 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 116, 219-225
Using lattice tools and unfolding methods for hpge detector efficiency simulation with the Monte Carlo code MCNP5
- 1 August 2015
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 82, 240-251
Application of the Monte Carlo method to analyze materials used in flat panel detectors to obtain X-ray spectra
- 1 August 2015
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 82, 240-251
Application of the Monte Carlo method to analyze materials used in flat panel detectors to obtain X-ray spectra
- 1 March 2015
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 283, 81-99
Simulation of a SBLOCA in a hot leg. Scaling considerations and application to a nuclear power plant
- 1 March 2015
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 283, 81-99
Simulation of a SBLOCA in a hot leg. Scaling considerations and application to a nuclear power plant
- 1 February 2014
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 95, 166-169
Application of the Monte Carlo codes PENELOPE and MCNP5 to unfold X-ray spectra in the diagnostic energy range
- 1 February 2014
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 95, 166-169
Application of the Monte Carlo codes PENELOPE and MCNP5 to unfold X-ray spectra in the diagnostic energy range
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 2384-2387
Unfolding X-ray spectra using a flat panel detector
It is difficult to measure the energy spectrum of X-ray tubes due to the pile up effect produced by the high fluence of photons. Using attenuating materials, appropriate detector devices and the Monte Carlo method, primary X-ray spectrum of these devices can be estimated. In this work, a flat panel detector with a PMMA wedge has been used to obtain a dose curve corresponding to certain working conditions of a radiodiagnostic X-ray tube. The relation between the dose curve recorded by the flat panel and the primary X-ray spectrum is defined by a response function. Normally this function can be approximated by a matrix, which can be obtained by means of the Monte Carlo method. Knowing the measured dose curve and the response matrix, the primary X-ray spectrum can be unfolded. However, there are some problems that strongly affect the applicability of this method: i.e. technical features of the flat panel and inherent characteristics of the involved radiation physics (ill-posed problem). Both aspects are analyzed in this work, concluding that the proposed method can be applied with an acceptable accuracy for spectra without characteristic lines, for instance, tungsten anode in the 50-70 kVp range.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 2384-2387
Unfolding X-ray spectra using a flat panel detector
It is difficult to measure the energy spectrum of X-ray tubes due to the pile up effect produced by the high fluence of photons. Using attenuating materials, appropriate detector devices and the Monte Carlo method, primary X-ray spectrum of these devices can be estimated. In this work, a flat panel detector with a PMMA wedge has been used to obtain a dose curve corresponding to certain working conditions of a radiodiagnostic X-ray tube. The relation between the dose curve recorded by the flat panel and the primary X-ray spectrum is defined by a response function. Normally this function can be approximated by a matrix, which can be obtained by means of the Monte Carlo method. Knowing the measured dose curve and the response matrix, the primary X-ray spectrum can be unfolded. However, there are some problems that strongly affect the applicability of this method: i.e. technical features of the flat panel and inherent characteristics of the involved radiation physics (ill-posed problem). Both aspects are analyzed in this work, concluding that the proposed method can be applied with an acceptable accuracy for spectra without characteristic lines, for instance, tungsten anode in the 50-70 kVp range.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2012 (1094687X) , 5777-5780
X-ray simulation with the Monte Carlo code PENELOPE. Application to Quality Control
A realistic knowledge of the energy spectrum is very important in Quality Control (QC) of X-ray tubes in order to reduce dose to patients. However, due to the implicit difficulties to measure the X-ray spectrum accurately, it is not normally obtained in routine QC. Instead, some parameters are measured and/or calculated. PENELOPE and MCNP5 codes, based on the Monte Carlo method, can be used as complementary tools to verify parameters measured in QC. These codes allow estimating Bremsstrahlung and characteristic lines from the anode taking into account specific characteristics of equipment. They have been applied to simulate an X-ray spectrum. Results are compared with theoretical IPEM 78 spectrum. A sensitivity analysis has been developed to estimate the influence on simulated spectra of important parameters used in simulation codes. With this analysis it has been obtained that the FORCE factor is the most important parameter in PENELOPE simulations. FORCE factor, which is a variance reduction method, improves the simulation but produces hard increases of computer time. The value of FORCE should be optimized so that a good agreement of simulated and theoretical spectra is reached, but with a reduction of computer time. Quality parameters such as Half Value Layer (HVL) can be obtained with the PENELOPE model developed, but FORCE takes such a high value that computer time is hardly increased. On the other hand, depth dose assessment can be achieved with acceptable results for small values of FORCE.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2012 (1094687X) , 5777-5780
X-ray simulation with the Monte Carlo code PENELOPE. Application to Quality Control
A realistic knowledge of the energy spectrum is very important in Quality Control (QC) of X-ray tubes in order to reduce dose to patients. However, due to the implicit difficulties to measure the X-ray spectrum accurately, it is not normally obtained in routine QC. Instead, some parameters are measured and/or calculated. PENELOPE and MCNP5 codes, based on the Monte Carlo method, can be used as complementary tools to verify parameters measured in QC. These codes allow estimating Bremsstrahlung and characteristic lines from the anode taking into account specific characteristics of equipment. They have been applied to simulate an X-ray spectrum. Results are compared with theoretical IPEM 78 spectrum. A sensitivity analysis has been developed to estimate the influence on simulated spectra of important parameters used in simulation codes. With this analysis it has been obtained that the FORCE factor is the most important parameter in PENELOPE simulations. FORCE factor, which is a variance reduction method, improves the simulation but produces hard increases of computer time. The value of FORCE should be optimized so that a good agreement of simulated and theoretical spectra is reached, but with a reduction of computer time. Quality parameters such as Half Value Layer (HVL) can be obtained with the PENELOPE model developed, but FORCE takes such a high value that computer time is hardly increased. On the other hand, depth dose assessment can be achieved with acceptable results for small values of FORCE.
- 30 July 2012
- Published by ASME International
- p. 579
Break Size Effects on CET Response in an Upper Head SBLOCA Transient
In the transients produced during Small Break Loss-Of-Coolant Accidents (SBLOCA), the maximum Peak Cladding Temperature (PCT) in the core could suffer rapid excursions which might strongly affect the core integrity. Most Pressurized Water Reactors (PWR) have Core Exit Thermocouples (CETs) to detect core overheating by considering that superheated steam flows in the upward direction when core uncovery occurs during SBLOCAs. Operators may start Accident Management (AM) actions to mitigate such accident conditions when the CET temperature exceeds a certain value. However, in a Vessel Upper Head SBLOCA, a significant delay in time and temperature rise of CETs from core heat-up can be produced. This work is developed in the frame of OECD/NEA ROSA Project Test 6-1 (SB-PV-9 in JAEA) handled in the Large Scale Test Facility (LSTF) of the Japan Atomic Energy Agency (JAEA). Test 6-1 simulated a PWR pressure vessel Upper-Head SBLOCA with a break size equivalent to 1.9% of the cold leg break under the assumption of total failure of High Pressure Injection System (HPIS). The paper shows several analyses about the geometry variables (size, location, flow paths and Upper Head nodalization) which can influence on the pressure vessel Upper Head SBLOCA model performed using the thermal-hydraulic code TRACE5.
- 30 July 2012
- Published by ASME International
- p. 579
Break Size Effects on CET Response in an Upper Head SBLOCA Transient
In the transients produced during Small Break Loss-Of-Coolant Accidents (SBLOCA), the maximum Peak Cladding Temperature (PCT) in the core could suffer rapid excursions which might strongly affect the core integrity. Most Pressurized Water Reactors (PWR) have Core Exit Thermocouples (CETs) to detect core overheating by considering that superheated steam flows in the upward direction when core uncovery occurs during SBLOCAs. Operators may start Accident Management (AM) actions to mitigate such accident conditions when the CET temperature exceeds a certain value. However, in a Vessel Upper Head SBLOCA, a significant delay in time and temperature rise of CETs from core heat-up can be produced. This work is developed in the frame of OECD/NEA ROSA Project Test 6-1 (SB-PV-9 in JAEA) handled in the Large Scale Test Facility (LSTF) of the Japan Atomic Energy Agency (JAEA). Test 6-1 simulated a PWR pressure vessel Upper-Head SBLOCA with a break size equivalent to 1.9% of the cold leg break under the assumption of total failure of High Pressure Injection System (HPIS). The paper shows several analyses about the geometry variables (size, location, flow paths and Upper Head nodalization) which can influence on the pressure vessel Upper Head SBLOCA model performed using the thermal-hydraulic code TRACE5.
- 1 November 2011
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 53 (8) , 1136-1139
Application of the MTSVD unfolding method for reconstruction of primary X-ray spectra using semiconductor detectors
- 1 November 2011
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 53 (8) , 1136-1139
Application of the MTSVD unfolding method for reconstruction of primary X-ray spectra using semiconductor detectors