S. Medvedeva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
S. Medvedeva has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ivan Lyatun
Immanuel Kant Baltic Federal University
2 shared publications - Aleksandr Barannikov
Immanuel Kant Baltic Federal University, Kaliningrad, Russia
1 shared publication - Anatoly Snigirev
International Science and Research Center “Coherent X-ray Optics for Megascience Facilities”, Immanuel Kant Baltic Federal University, 236022 Kaliningrad, Russia
1 shared publication - Arcady Zhukov
Department of Polymers and Advanced Materials, Faculty of Chemistry, University of the Basque Country, UPV/EHU, 20018 San Sebastián, Spain
1 shared publication - Irina Snigireva
The European Synchrotron Radiation Facility (ESRF) Grenoble France
1 shared publication - M. A. Voevodina
Immanuel Kant Baltic Federal University, 14 Nevskogo, 236041 Kaliningrad, Russian Federation
1 shared publication
Latest Publications
- 1 January 2021
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 15 (1) , 39-45
X-ray Reflecto-Interferometry Technique Using a Microfocus Laboratory Source
An X-ray interferometry technique using an X-ray microfocus laboratory source for thin-film structure research based on compound refractive lenses has been proposed. The main advantage of this technique is to use a very simplified experimental setup where a focused X-ray beam reflected from parallel flat surfaces creates an interference pattern in a wide angular range. Due to this, the interference pattern can be obtained in a single shot without the need to rotate the specimen or the detector. The applicability of this technique has been demonstrated using the MetalJet Excillium micro-focus laboratory source, which has GaKα emission line at 9.25 keV. As a result, a series of interference patterns for test sample a free-standing thin-film membrane, thickness 500 nm, was observed. Based on the obtained results the main advantages of this technique such as high spatial and temporal resolution are shown, and also possible application of the reflecto-interferometry both at the laboratory and synchrotron radiation X-ray sources are proposed.
- 1 January 2021
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 15 (1) , 39-45
X-ray Reflecto-Interferometry Technique Using a Microfocus Laboratory Source
An X-ray interferometry technique using an X-ray microfocus laboratory source for thin-film structure research based on compound refractive lenses has been proposed. The main advantage of this technique is to use a very simplified experimental setup where a focused X-ray beam reflected from parallel flat surfaces creates an interference pattern in a wide angular range. Due to this, the interference pattern can be obtained in a single shot without the need to rotate the specimen or the detector. The applicability of this technique has been demonstrated using the MetalJet Excillium micro-focus laboratory source, which has GaKα emission line at 9.25 keV. As a result, a series of interference patterns for test sample a free-standing thin-film membrane, thickness 500 nm, was observed. Based on the obtained results the main advantages of this technique such as high spatial and temporal resolution are shown, and also possible application of the reflecto-interferometry both at the laboratory and synchrotron radiation X-ray sources are proposed.
- 7 May 2018
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 123 (17) , 173903
Radial elemental and phase separation in Ni-Mn-Ga glass-coated microwires
In this manuscript, radial elemental and phase separation in Ni-Mn-Ga glass-coated microwires with high excess Ni as a result of high-temperature annealing was observed. Partial manganese evaporation from the outer part of the metallic nucleus and glass melting results in the formation of manganese oxide at the surface. The lack of manganese due to its evaporation induces Ni3Ga formation in the intermediate part, while in the middle part of the metallic nucleus, the residual L21 phase with an average chemical composition of Ni60Mn9Ga31 remains. The layered structure exhibits soft ferromagnetic behavior below 270 K. The results were discussed taking into account the chemical composition, arising internal stresses, recrystallization, and atomic ordering.
- 7 May 2018
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 123 (17) , 173903
Radial elemental and phase separation in Ni-Mn-Ga glass-coated microwires
In this manuscript, radial elemental and phase separation in Ni-Mn-Ga glass-coated microwires with high excess Ni as a result of high-temperature annealing was observed. Partial manganese evaporation from the outer part of the metallic nucleus and glass melting results in the formation of manganese oxide at the surface. The lack of manganese due to its evaporation induces Ni3Ga formation in the intermediate part, while in the middle part of the metallic nucleus, the residual L21 phase with an average chemical composition of Ni60Mn9Ga31 remains. The layered structure exhibits soft ferromagnetic behavior below 270 K. The results were discussed taking into account the chemical composition, arising internal stresses, recrystallization, and atomic ordering.