Latest Publications

  • Open Access

    Separated Liquid–Vapor Flow Analysis in a Mini-Channel with Mesh Walls in the Closed-Loop Two-Phase Wicked Thermosyphon (CLTPWT)

    by Karthik S. Remella, Frank M. Gerner

    A metallic wire mesh screen, wire diameter of approximately 50 μm, is folded into ~80 “accordion-shaped” mini-channels and placed inside the evaporator package of a novel passive thermal management device for cooling overhead light-emitting diodes (LEDs) used in factory floors and high-bay facilities. The thermal power dissipated via these devices ranges between 75 W and 171 W. The channel walls (screen) wick liquid water from the porous wick (located centrally above the screen) and facilitate its evaporation. The closed-loop tests on this device confirm that the two-phase mixture quality exiting the evaporator is approximately 0.2. This paper presents a steady-state numerical model of this separated liquid–vapor flow in a single mini-rectangular channel (900 μm × 2000 μm, 4 cm long) with wire mesh-screen walls. The primary objective of the model is to estimate the pressure drops occurring in this two-phase flow. The model initially assumes a flat liquid–vapor interface along the channel and uses an iterative approach to estimate its final meniscus shape (curvature). In addition to the temperature distribution along the screen walls, this paper also discusses the velocity and pressure distributions in both liquid and vapor regions. It also helps understand the liquid–vapor interfacial shear in this flow configuration and proposes a flow-limiting condition for the device by predicting flow reversal in the channel.

  • Thin-Film Evaporation in a Mesh Screen Wick

    by Karthik S. Remella, Frank M. Gerner

    Porous capillary wick structures are being employed in two-phase thermal management devices owing to their pumping capabilities and thermal performance enhancement during evaporation of the working fluid. Thin-film evaporation in a porous wick depends primarily on the shape of the liquid–vapor meniscus, especially near the wall. The primary objective of this paper is to study and investigate the thin-film evaporation of the liquid in a unit cell representation (UCR) of a single layer of a metallic wire mesh screen. The volume-of-fluid (VOF) method, which is an interface-capturing technique in multiphase flow modeling, is employed to obtain the steady-state meniscus shape under equilibrium conditions. This paper demonstrates the impact of the equilibrium contact angle (θ) and the initial meniscus height (H) on the steady-state interfacial pressure difference. It outlines a detailed process for estimating 3D interfacial surfaces, obtained from the VOF solution, to generate the final geometry for the thin-film evaporation analysis. A static meniscus heat-transfer model is subsequently solved using the commercial finite volume code, ansysfluent, to obtain the temperature and flow characteristics during evaporation. The relationship of parameters such as the average evaporation mass fluxes and heat transfer coefficients are estimated and presented in this paper. Finally, the relationship between the pressure drop across the liquid–vapor meniscus and the thin-film evaporation rate for screen mesh wicks is discussed.


  • Mathematical Modeling of Novel Two-Phase Heat Transfer Device for Thermal Management of Light Emitting Diodes

    by Karthik S. Remella, Frank M. Gerner, Ahmed Shuja

    The paper introduces a novel two-phase heat transfer device (TPHTD) which is employed in the thermal management of light emitting diodes (LEDs). The heat transfer device structurally resembles a conventional loop heat pipe (LHP) without a compensation chamber, but operates very differently from it. The device is comprised of a central evaporator package and a circular coil that acts as a heat exchanger loop. The working fluid leaving the evaporator has a two-phase mixture quality of approximately 0.2. Having introduced the device, the paper delineates a mathematical model for predicting its thermal performance. The primary objective of the model is to provide a fundamental understanding of the operation of the device. A one-dimensional thermal resistance model (TRM) is utilized in modeling the evaporator. The paper presents a detailed discussion on obtaining these resistances from experiments conducted on the device. A correlation for the external heat transfer coefficient of the heat exchanger loop is proposed based on experiments and is found to be in good agreement with literature. The model predicts performance parameters such as board temperature, two-phase mixture quality, and saturation and subcooled temperatures (Tsat and Tsc) of the working fluid for different input thermal powers (Qtot). Based on experimental evidence, it is concluded that the majority of Qtot (∼75%) is utilized in phase change of the working fluid, and the rest reheats the working fluid from a lower subcooled temperature (Tsc) to the saturation temperature (Tsat) of the evaporator.