Yijing Gong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yijing Gong has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jianghai Geng
Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China
2 shared publications - Yuming Zhang
Hebei Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China
2 shared publications - Lincong Chen
Key Laboratory of Physical and Chemical Analysis for Electric Power of Hainan Province, Hainan Power Grid Co., Ltd., Electric Power Research Institute, Haikou 570125, China
1 shared publication - Simin Zhang
Hebei Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China
1 shared publication - Sizu Hou
School of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, China
1 shared publication - Xiaotao Fu
Key Laboratory of Physical and Chemical Analysis for Electric Power of Hainan Province, Hainan Power Grid Co., Ltd., Electric Power Research Institute, Haikou 570125, China
1 shared publication
Latest Publications
- Open Access
Study on the Ageing Characteristics of Silicone Rubber for Composite Insulators under Multi-Factor Coupling Effects
Due to long-term exposure to high electrical field strength, heavy loads, and the complex climatic conditions in tropical coastal areas of China, widespread abnormal heating phenomena often occur in the operation of composite insulators in power transmission lines, posing a threat to the safe and stable operation of the power system. To study the ageing process of the silicone rubber sheath of composite insulators in the high-field, high-humidity, high-temperature, and high-salt-density environments along the coastal regions, this paper establishes a humidity–heat–electricity–salt spray accelerated ageing test platform and conducts ageing tests on silicone rubber materials for composite insulators under the coupled effect of multiple factors. The ageing characteristics of silicone rubber materials are analyzed using scanning electron microscopy, Fourier infrared spectroscopy, thermogravimetric analysis, and other methods. The results show that the coupled ageing factors have an impact on the surface morphology of silicone rubber. The continuous depolymerization of PDMS molecular chains leads to a decrease in the content of groups related to the hydrophobicity of the material, resulting in a deterioration of its hydrophobicity. Moreover, the degradation of silicone rubber materials and the enhanced moisture absorption capacity lead to an increase in the dielectric loss tangent of the saturated moisture-absorbing medium, thereby causing abnormal heating of the sheath at the end of the composite insulator. The research findings of this study are of significant reference value for revealing the degradation mechanism of composite insulator silicone rubber sheaths in tropical island environments and improving the service life of composite insulators.
Open AccessStudy on the Ageing Characteristics of Silicone Rubber for Composite Insulators under Multi-Factor Coupling Effects
Due to long-term exposure to high electrical field strength, heavy loads, and the complex climatic conditions in tropical coastal areas of China, widespread abnormal heating phenomena often occur in the operation of composite insulators in power transmission lines, posing a threat to the safe and stable operation of the power system. To study the ageing process of the silicone rubber sheath of composite insulators in the high-field, high-humidity, high-temperature, and high-salt-density environments along the coastal regions, this paper establishes a humidity–heat–electricity–salt spray accelerated ageing test platform and conducts ageing tests on silicone rubber materials for composite insulators under the coupled effect of multiple factors. The ageing characteristics of silicone rubber materials are analyzed using scanning electron microscopy, Fourier infrared spectroscopy, thermogravimetric analysis, and other methods. The results show that the coupled ageing factors have an impact on the surface morphology of silicone rubber. The continuous depolymerization of PDMS molecular chains leads to a decrease in the content of groups related to the hydrophobicity of the material, resulting in a deterioration of its hydrophobicity. Moreover, the degradation of silicone rubber materials and the enhanced moisture absorption capacity lead to an increase in the dielectric loss tangent of the saturated moisture-absorbing medium, thereby causing abnormal heating of the sheath at the end of the composite insulator. The research findings of this study are of significant reference value for revealing the degradation mechanism of composite insulator silicone rubber sheaths in tropical island environments and improving the service life of composite insulators.
- Open Access
Diagnosis Method of Decay-like Composite Insulators in a High-Humidity Environment Based on Characteristic Coefficient of Temperature Rise Gradient
At present, the temperature rise in insulators is observed using infrared thermometry as a common method of diagnosing decay-like insulators. However, the original characteristic data obtained by infrared thermometry cannot effectively distinguish some of the decay-like insulators from those with ageing sheaths. Therefore, it is imperative to find a new diagnostic characteristic quantity. Based on statistical data, this article first explains that existing diagnostic methods have limited diagnostic effectiveness and a high false detection rate for insulators in a slightly heated state. A full-scale temperature rise test is carried out on a batch of composite insulators returned from the field under high-humidity conditions. Two different defective insulators with similar temperature rise profiles are identified, and an electro-thermal coupling simulation model is developed based on the dielectric characteristic parameters of the above insulators for both core rod defects and sheath ageing. A new infrared diagnostic feature, the temperature rise gradient coefficient, is then obtained to identify the source of abnormal heat in insulators using statistical analysis of an infrared image gallery of abnormally hot composite insulators obtained from field inspections and laboratory tests.
Open AccessDiagnosis Method of Decay-like Composite Insulators in a High-Humidity Environment Based on Characteristic Coefficient of Temperature Rise Gradient
At present, the temperature rise in insulators is observed using infrared thermometry as a common method of diagnosing decay-like insulators. However, the original characteristic data obtained by infrared thermometry cannot effectively distinguish some of the decay-like insulators from those with ageing sheaths. Therefore, it is imperative to find a new diagnostic characteristic quantity. Based on statistical data, this article first explains that existing diagnostic methods have limited diagnostic effectiveness and a high false detection rate for insulators in a slightly heated state. A full-scale temperature rise test is carried out on a batch of composite insulators returned from the field under high-humidity conditions. Two different defective insulators with similar temperature rise profiles are identified, and an electro-thermal coupling simulation model is developed based on the dielectric characteristic parameters of the above insulators for both core rod defects and sheath ageing. A new infrared diagnostic feature, the temperature rise gradient coefficient, is then obtained to identify the source of abnormal heat in insulators using statistical analysis of an infrared image gallery of abnormally hot composite insulators obtained from field inspections and laboratory tests.