André Vitor Rocha Queiroz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
André Vitor Rocha Queiroz has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bárbara Caroline Dias Faria
Universidade Federal de Minas Gerais, Faculdade de Medicina, Belo Horizonte MG, Brazil
1 shared publication - Fernanda de Andrade Dias Leite
Faculdade Ciências Médicas de Minas Gerais, Belo Horizonte, MG. Brasil
1 shared publication - Henrique Lacerda Lage Lopes de Oliveira
Universidade Federal de Minas Gerais, Faculdade de Medicina, Belo Horizonte MG, Brazil
1 shared publication - Luiz Gustavo Guimarães Sacramento
Universidade Federal de Minas Gerais, Faculdade de Medicina, Belo Horizonte MG, Brazil
1 shared publication - Rodrigo Moreira Faleiro
Department of Neurosurgery, Hospital Felício Rocho, Belo Horizonte, MG, Brazil
1 shared publication - Thais Yuki Kimura
Department of Physiology and Biophysics, Institute of Biological Science, Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG, Brazil
1 shared publication
Latest Publications
- Open Access
- 28 June 2023
- Published by Georg Thieme Verlag KG in Arquivos de Neuro-Psiquiatria
- Vol. 81 (06) , 551-563
The use of noninvasive measurements of intracranial pressure in patients with traumatic brain injury: a narrative review
Background The most frequent cause of death in neurosurgical patients is due to the increase in intracranial pressure (ICP); consequently, adequate monitoring of this parameter is extremely important. Objectives In this study, we aimed to analyze the accuracy of noninvasive measurement methods for intracranial hypertension (IH) in patients with traumatic brain injury (TBI). Methods The data were obtained from the PubMed database, using the following terms: intracranial pressure, noninvasive, monitoring, assessment, and measurement. The selected articles date from 1980 to 2021, all of which were observational studies or clinical trials, in English and specifying ICP measurement in TBI. At the end of the selection, 21 articles were included in this review. Results The optic nerve sheath diameter (ONSD), pupillometry, transcranial doppler (TCD), multimodal combination, brain compliance using ICP waveform (ICPW), HeadSense, and Visual flash evoked pressure (FVEP) were analyzed. Pupillometry was not found to correlate with ICP, while HeadSense monitor and the FVEP method appear to have good correlation, but sensitivity and specificity data are not available. The ONSD and TCD methods showed good-to-moderate accuracy on invasive ICP values and potential to detect IH in most studies. Furthermore, multimodal combination may reduce the error possibility related to each technique. Finally, ICPW showed good accuracy to ICP values, but this analysis included TBI and non-TBI patients in the same sample. Conclusions Noninvasive ICP monitoring methods may be used in the near future to guide TBI patients' management.
- 28 June 2023
- Published by Georg Thieme Verlag KG in Arquivos de Neuro-Psiquiatria
- Vol. 81 (06) , 551-563
Open AccessThe use of noninvasive measurements of intracranial pressure in patients with traumatic brain injury: a narrative review
Background The most frequent cause of death in neurosurgical patients is due to the increase in intracranial pressure (ICP); consequently, adequate monitoring of this parameter is extremely important. Objectives In this study, we aimed to analyze the accuracy of noninvasive measurement methods for intracranial hypertension (IH) in patients with traumatic brain injury (TBI). Methods The data were obtained from the PubMed database, using the following terms: intracranial pressure, noninvasive, monitoring, assessment, and measurement. The selected articles date from 1980 to 2021, all of which were observational studies or clinical trials, in English and specifying ICP measurement in TBI. At the end of the selection, 21 articles were included in this review. Results The optic nerve sheath diameter (ONSD), pupillometry, transcranial doppler (TCD), multimodal combination, brain compliance using ICP waveform (ICPW), HeadSense, and Visual flash evoked pressure (FVEP) were analyzed. Pupillometry was not found to correlate with ICP, while HeadSense monitor and the FVEP method appear to have good correlation, but sensitivity and specificity data are not available. The ONSD and TCD methods showed good-to-moderate accuracy on invasive ICP values and potential to detect IH in most studies. Furthermore, multimodal combination may reduce the error possibility related to each technique. Finally, ICPW showed good accuracy to ICP values, but this analysis included TBI and non-TBI patients in the same sample. Conclusions Noninvasive ICP monitoring methods may be used in the near future to guide TBI patients' management.