The use of noninvasive measurements of intracranial pressure in patients with traumatic brain injury: a narrative review
Authors:
- Bárbara Caroline Dias FariaBFBárbara Caroline Dias Faria
- Luiz Gustavo Guimarães SacramentoLSLuiz Gustavo Guimarães Sacramento
- André Vitor Rocha QueirozAQAndré Vitor Rocha Queiroz
- Fernanda de Andrade Dias LeiteFLFernanda de Andrade Dias Leite
- Henrique Lacerda Lage Lopes de OliveiraHOHenrique Lacerda Lage Lopes de Oliveira
- Thais Yuki KimuraTKThais Yuki Kimura
- Rodrigo Moreira FaleiroRFRodrigo Moreira Faleiro
Open Access
- 28 June 2023
- journal article
- review article
- Published by Georg Thieme Verlag KG in Arquivos de Neuro-Psiquiatria
- Vol. 81 (06) , 551-563
Abstract
Background The most frequent cause of death in neurosurgical patients is due to the increase in intracranial pressure (ICP); consequently, adequate monitoring of this parameter is extremely important. Objectives In this study, we aimed to analyze the accuracy of noninvasive measurement methods for intracranial hypertension (IH) in patients with traumatic brain injury (TBI). Methods The data were obtained from the PubMed database, using the following terms: intracranial pressure, noninvasive, monitoring, assessment, and measurement. The selected articles date from 1980 to 2021, all of which were observational studies or clinical trials, in English and specifying ICP measurement in TBI. At the end of the selection, 21 articles were included in this review. Results The optic nerve sheath diameter (ONSD), pupillometry, transcranial doppler (TCD), multimodal combination, brain compliance using ICP waveform (ICPW), HeadSense, and Visual flash evoked pressure (FVEP) were analyzed. Pupillometry was not found to correlate with ICP, while HeadSense monitor and the FVEP method appear to have good correlation, but sensitivity and specificity data are not available. The ONSD and TCD methods showed good-to-moderate accuracy on invasive ICP values and potential to detect IH in most studies. Furthermore, multimodal combination may reduce the error possibility related to each technique. Finally, ICPW showed good accuracy to ICP values, but this analysis included TBI and non-TBI patients in the same sample. Conclusions Noninvasive ICP monitoring methods may be used in the near future to guide TBI patients' management.Keywords
This publication has 27 references indexed in Scilit:
- Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressureJournal of Neurosurgery, 2015
- Research on simulation and experiment of noninvasive intracranial pressure monitoring based on acoustoelasticity effectsMedical Devices: Evidence and Research, 2013
- The New ICP Minimally Invasive Method Shows That the Monro–Kellie Doctrine Is Not Valid2012
- Sonographic Optic Nerve Sheath Diameter as an Estimate of Intracranial Pressure in Adult TraumaJournal of Surgical Research, 2011
- Optic Nerve Ultrasound for the Detection of Raised Intracranial PressureNeurocritical Care, 2011
- Optic nerve sonography in the diagnostic evaluation of adult brain injuryCritical Care, 2008
- Fuzzy pattern classification of hemodynamic data can be used to determine noninvasive intracranial pressure2005
- Adaptive Noninvasive Assessment of Intracranial Pressure and Cerebral AutoregulationStroke, 2003
- Cerebral perfusion pressure in head-injured patients: a noninvasive assessment using transcranial Doppler ultrasonographyJournal of Neurosurgery, 1998
- Bedside measurement of the third ventricle's diameter during episodes of arising intracranial pressure after head traumaActa Neurochirurgica, 1995