Maya C. Shammas
Research Subjects
Maya C. Shammas has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- H. John Shammas
From the Department of Ophthalmology, the Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA
7 shared publications - Renu V. Jivrajka
Shammas Eye Medical Center, Lynwood, CA, USA
2 shared publications - Abdelrahman M. Anter
From the Bascom Palmer Eye Institute (S.S., A.M.A., S.L., R.S.T.), University of Miami, Miami, Florida, USA
1 shared publication Adam Bleeker
Dean McGee Eye Institute, University of Oklahoma, Oklahoma City, Oklahoma
1 shared publication- Brad Hall
Sengi, Penniac, NB, Canada
1 shared publication - Christine Hakimeh1 shared publication
Latest Publications
- Open Access
- 1 May 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 1693-1697
Impact of Best Corrected Final Visual Acuity on the Performance of Intraocular Lens Power Calculations
Purpose: To evaluate the impact of the best-corrected final visual acuity (BCFVA) on the accuracy of intraocular lens (IOL) power calculations. Design, Setting and Methods: This is a retrospective observational study in a private practice setting, Lynwood, California, USA. We analyzed 1107 eyes undergoing standard monofocal cataract surgery, with IOL power calculated using the Barrett Universal II formula. We evaluated the Mean Prediction Error (MPE) and its standard deviation (SD), the Mean Absolute Error (MAE) and its SD and the percentage of eyes within ± 0.50D and ± 1.00D in relation to BCFVA. Results: We analyzed 4 groups with BCFVA noted in LogMAR of ≤ 0.00, 0.02– 0.10, 0.12– 0.20 and 0.22– 0.30. MPE was − 0.030± 0.321, − 0.018± 0.353, 0.015± 0.369 and 0.070± 0.421 D, respectively. MAE was 0.263± 0.186, 0.282± 0.213, 0.301± 0.214 and 0.354± 0.236 D, respectively. The percentage of eyes within ± 0.50D was 85.9%, 82.6%, 81.5% and 75.5%, respectively. A subgroup analysis of the 1005 eyes with BCFVA of 0.20 LogMAR or better resulted in an MPE of − 0.007± 0.354 D, a MAE of 0.285± 0.209 D and a percentage of eyes within ± 0.50D of 82.8%. The difference between this subgroup and the group of eyes with a BCFVA 0.22– 0.30 was statistically significant (p< 0.001). Conclusion: Better IOL power predictions were noted by limiting the study to eyes with BCFVA of 0.20 LogMAR or better. Plain Language Summary: During cataract surgery, the clouded natural lens of the eye is removed and replaced with an intraocular lens, or IOL. Prior to surgery, calculations are required to determine the power of the IOL to be inserted in the eye at the time of surgery. Many studies evaluate the accuracy of such calculations by comparing the final refraction to the predicted one. Most of these patients are seniors and some of them present with concomitant retinal problems that limit the final visual acuity. Studies usually evaluate eyes that have achieved a vision of 0.30 LogMAR (20/40) or better. Our results showed that limiting the analysis to only those eyes that have achieved 0.20 LogMAR (20/32) or better will result in a more accurate evaluation of these predictions by eliminating those cases with poorer final vision that are prone to a higher variability in the post-operative refraction.
- 1 May 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 1693-1697
Open AccessImpact of Best Corrected Final Visual Acuity on the Performance of Intraocular Lens Power Calculations
Purpose: To evaluate the impact of the best-corrected final visual acuity (BCFVA) on the accuracy of intraocular lens (IOL) power calculations. Design, Setting and Methods: This is a retrospective observational study in a private practice setting, Lynwood, California, USA. We analyzed 1107 eyes undergoing standard monofocal cataract surgery, with IOL power calculated using the Barrett Universal II formula. We evaluated the Mean Prediction Error (MPE) and its standard deviation (SD), the Mean Absolute Error (MAE) and its SD and the percentage of eyes within ± 0.50D and ± 1.00D in relation to BCFVA. Results: We analyzed 4 groups with BCFVA noted in LogMAR of ≤ 0.00, 0.02– 0.10, 0.12– 0.20 and 0.22– 0.30. MPE was − 0.030± 0.321, − 0.018± 0.353, 0.015± 0.369 and 0.070± 0.421 D, respectively. MAE was 0.263± 0.186, 0.282± 0.213, 0.301± 0.214 and 0.354± 0.236 D, respectively. The percentage of eyes within ± 0.50D was 85.9%, 82.6%, 81.5% and 75.5%, respectively. A subgroup analysis of the 1005 eyes with BCFVA of 0.20 LogMAR or better resulted in an MPE of − 0.007± 0.354 D, a MAE of 0.285± 0.209 D and a percentage of eyes within ± 0.50D of 82.8%. The difference between this subgroup and the group of eyes with a BCFVA 0.22– 0.30 was statistically significant (p< 0.001). Conclusion: Better IOL power predictions were noted by limiting the study to eyes with BCFVA of 0.20 LogMAR or better. Plain Language Summary: During cataract surgery, the clouded natural lens of the eye is removed and replaced with an intraocular lens, or IOL. Prior to surgery, calculations are required to determine the power of the IOL to be inserted in the eye at the time of surgery. Many studies evaluate the accuracy of such calculations by comparing the final refraction to the predicted one. Most of these patients are seniors and some of them present with concomitant retinal problems that limit the final visual acuity. Studies usually evaluate eyes that have achieved a vision of 0.30 LogMAR (20/40) or better. Our results showed that limiting the analysis to only those eyes that have achieved 0.20 LogMAR (20/32) or better will result in a more accurate evaluation of these predictions by eliminating those cases with poorer final vision that are prone to a higher variability in the post-operative refraction.
- Open Access
- 1 December 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 4063-4070
Visual and Refractive Outcomes After Bilateral Implantation of a New Toric Intraocular Lens
Purpose: To evaluate the clinical outcomes of a new FDA approved toric aspheric hydrophobic acrylic intraocular lens. Patients and Methods: This is a single surgeon, single-arm, on-label, non-randomized, prospective observational study. Thirty patients underwent bilateral cataract surgery (60 eyes) with placement of a Clareon™ Toric IOL in each eye. The Barrett Universal II formula and Barrett toric calculator were used to determine the IOL power and toric axis. Endpoints included binocular and monocular best corrected distance visual acuity (BCDVA), binocular and monocular best uncorrected distance visual acuity (UCDVA), binocular uncorrected intermediate visual acuity (UCIVA), manifest refraction and patient Satisfaction Survey (IOLSAT) results over a 3 month follow-up. Results: The postoperative mean LogMAR visual acuity for binocular BCDVA and UCDVA were each 0.01± 0.05. The monocular BCDVA and UCDVA were 0.04± 0.06 and 0.08± 0.08 respectively. The mean refractive cylinder improved from 1.87± 1.12D to 0.43± 0.25D with 78.3% within 0.50D. The mean refractive spherical equivalent (MRSE) was 0.008 ± 0.30 D (range − 0.75 to +0.63, 93.3% results within ± 0.5D). Patient surveys showed 96.7% gained distance spectacle independence and 96.7% would recommend this lens to friends or family members. Conclusion: The Clareon Monofocal Toric IOL is effective in astigmatism correction and significantly improved uncorrected distance visual acuity. High spectacle independence for distance vision and high overall satisfaction were achieved.
- 1 December 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 4063-4070
Open AccessVisual and Refractive Outcomes After Bilateral Implantation of a New Toric Intraocular Lens
Purpose: To evaluate the clinical outcomes of a new FDA approved toric aspheric hydrophobic acrylic intraocular lens. Patients and Methods: This is a single surgeon, single-arm, on-label, non-randomized, prospective observational study. Thirty patients underwent bilateral cataract surgery (60 eyes) with placement of a Clareon™ Toric IOL in each eye. The Barrett Universal II formula and Barrett toric calculator were used to determine the IOL power and toric axis. Endpoints included binocular and monocular best corrected distance visual acuity (BCDVA), binocular and monocular best uncorrected distance visual acuity (UCDVA), binocular uncorrected intermediate visual acuity (UCIVA), manifest refraction and patient Satisfaction Survey (IOLSAT) results over a 3 month follow-up. Results: The postoperative mean LogMAR visual acuity for binocular BCDVA and UCDVA were each 0.01± 0.05. The monocular BCDVA and UCDVA were 0.04± 0.06 and 0.08± 0.08 respectively. The mean refractive cylinder improved from 1.87± 1.12D to 0.43± 0.25D with 78.3% within 0.50D. The mean refractive spherical equivalent (MRSE) was 0.008 ± 0.30 D (range − 0.75 to +0.63, 93.3% results within ± 0.5D). Patient surveys showed 96.7% gained distance spectacle independence and 96.7% would recommend this lens to friends or family members. Conclusion: The Clareon Monofocal Toric IOL is effective in astigmatism correction and significantly improved uncorrected distance visual acuity. High spectacle independence for distance vision and high overall satisfaction were achieved.
- Open Access
- 1 October 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (10) , 1026-1029
Updating the no-history method in intraocular lens power calculation after myopic laser vision correction
Purpose: To describe the Shammas-Cooke formula, an updated no-history (NH) formula for IOL calculation in eyes with prior myopic laser vision correction (M-LVC), and to compare the results with the Shammas PL, Haigis-L, and Barrett True-K NH formulas. Setting: Bascom Palmer Eye Institute (BPEI), The Lennar Foundation Medical Center, University of Miami, Miami, Florida; Dean A. McGee Eye Institute (DMEI), University of Oklahoma, Oklahoma City, Oklahoma; and private practice, Lynwood, California, and St Joseph, Michigan. Design: Retrospective observational study. Methods: We analyzed 2 large series of cataractous eyes with prior M-LVC. The training set (BPEI series of 330 eyes) was used to derive the new corneal power conversion equation to be used in the new Shammas-Cooke formula and the testing set (165 eyes of 165 patients in the DMEI series) to compare the updated formula with 3 other M-LVC NH formulas on the ASCRS calculator: Shammas PL, Haigis-L, and Barrett True-K NH. Results: Mean prediction error was 0.09 ± 0.56 diopters (D), −0.44 ± 0.61 D, −0.47 ± 0.59 D, and −0.18 ± 0.56 D and the mean absolute error was 0.43 D, 0.60 D, 0.61 D, and 0.45 D for the Shammas-Cooke, Shammas PL, Haigis-L, and Barrett True-K NH, respectively. The percentage of eyes within ±0.50 D was 66.7% vs 47.9%, 48.5%, and 65.5%, respectively. Conclusions: The Shammas-Cooke formula performed better than the Shammas PL and Haigis-L (P < .001 for both) and as well as the Barrett True-K NH formula (P = .923).
- 1 October 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (10) , 1026-1029
Open AccessUpdating the no-history method in intraocular lens power calculation after myopic laser vision correction
Purpose: To describe the Shammas-Cooke formula, an updated no-history (NH) formula for IOL calculation in eyes with prior myopic laser vision correction (M-LVC), and to compare the results with the Shammas PL, Haigis-L, and Barrett True-K NH formulas. Setting: Bascom Palmer Eye Institute (BPEI), The Lennar Foundation Medical Center, University of Miami, Miami, Florida; Dean A. McGee Eye Institute (DMEI), University of Oklahoma, Oklahoma City, Oklahoma; and private practice, Lynwood, California, and St Joseph, Michigan. Design: Retrospective observational study. Methods: We analyzed 2 large series of cataractous eyes with prior M-LVC. The training set (BPEI series of 330 eyes) was used to derive the new corneal power conversion equation to be used in the new Shammas-Cooke formula and the testing set (165 eyes of 165 patients in the DMEI series) to compare the updated formula with 3 other M-LVC NH formulas on the ASCRS calculator: Shammas PL, Haigis-L, and Barrett True-K NH. Results: Mean prediction error was 0.09 ± 0.56 diopters (D), −0.44 ± 0.61 D, −0.47 ± 0.59 D, and −0.18 ± 0.56 D and the mean absolute error was 0.43 D, 0.60 D, 0.61 D, and 0.45 D for the Shammas-Cooke, Shammas PL, Haigis-L, and Barrett True-K NH, respectively. The percentage of eyes within ±0.50 D was 66.7% vs 47.9%, 48.5%, and 65.5%, respectively. Conclusions: The Shammas-Cooke formula performed better than the Shammas PL and Haigis-L (P < .001 for both) and as well as the Barrett True-K NH formula (P = .923).
- 1 June 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (6) , 653-654
White-to-white corneal measurement compared to corneal diameter measured by SS-OCT
- 1 June 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (6) , 653-654
White-to-white corneal measurement compared to corneal diameter measured by SS-OCT
- Open Access
- 27 April 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (10) , 1113-1120
Accuracy of newer intraocular lens power formulas in short and long eyes using sum-of-segments biometry
Purpose: To analyze the accuracy of newer intraocular lens power formulas in long and short eyes measured using the sum-of-segments biometry. Setting: Private practice, Lynwood, California. Design: Retrospective observational study. Methods: 595 patients scheduled for cataract surgery had their eyes measured using the sum-of-segments biometry. The expected residual refractions were calculated using Barrett Universal II (B II), Barrett True Axial Length (BTAL), Emmetropia Verifying Optical (EVO), Hill-RBF, Hoffer QST, Holladay 2, Holladay 2-NLR, K6, Kane, Olsen, PEARL-DGS, T2, and VRF formulas and compared with the traditional Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Results: In the 102 long eyes, all new formulas had a mean absolute error (MAE) equal or lower than the traditional formulas, ranging from 0.29 to 0.32 diopter (D). In the 78 short eyes, BTAL, EVO, Hoffer QST, K6, Olsen, and PEARL-DGS formulas had the lowest MAE (0.33 D, 0.33 D, 0.31 D, 0.36 D, 0.32 D, and 0.32 D, respectively), whereas all traditional formulas exceeded 0.36 D. Conclusions: All new formulas performed equal or better than the traditional formulas with the sum-of-segments biometry. The best overall results in the short and long eyes as well as in the very short and very long eyes were noted with the BTAL, EVO, Hoffer QST, K6, Olsen, and PEARL-DGS formulas, closely followed by the B II and Kane formulas.
- 27 April 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (10) , 1113-1120
Open AccessAccuracy of newer intraocular lens power formulas in short and long eyes using sum-of-segments biometry
Purpose: To analyze the accuracy of newer intraocular lens power formulas in long and short eyes measured using the sum-of-segments biometry. Setting: Private practice, Lynwood, California. Design: Retrospective observational study. Methods: 595 patients scheduled for cataract surgery had their eyes measured using the sum-of-segments biometry. The expected residual refractions were calculated using Barrett Universal II (B II), Barrett True Axial Length (BTAL), Emmetropia Verifying Optical (EVO), Hill-RBF, Hoffer QST, Holladay 2, Holladay 2-NLR, K6, Kane, Olsen, PEARL-DGS, T2, and VRF formulas and compared with the traditional Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Results: In the 102 long eyes, all new formulas had a mean absolute error (MAE) equal or lower than the traditional formulas, ranging from 0.29 to 0.32 diopter (D). In the 78 short eyes, BTAL, EVO, Hoffer QST, K6, Olsen, and PEARL-DGS formulas had the lowest MAE (0.33 D, 0.33 D, 0.31 D, 0.36 D, 0.32 D, and 0.32 D, respectively), whereas all traditional formulas exceeded 0.36 D. Conclusions: All new formulas performed equal or better than the traditional formulas with the sum-of-segments biometry. The best overall results in the short and long eyes as well as in the very short and very long eyes were noted with the BTAL, EVO, Hoffer QST, K6, Olsen, and PEARL-DGS formulas, closely followed by the B II and Kane formulas.
- Open Access
- 21 September 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (6) , 690-696
Predicted vs measured posterior corneal astigmatism for toric intraocular lens calculations
Purpose: To evaluate the astigmatic correction obtained with a toric intraocular lens using the keratometric readings (Ks) from a swept-source optical coherence tomography (SS-OCT) biometer and the Barrett toric formula with its predicted posterior corneal astigmatism (PCA) value and to compare the results with those expected by using the OCT Ks and a measured PCA from a scheimpflug topographer and by using the SimKs and the measured PCA from the Scheimpflug topographer. Setting: Private practice, Lynwood, California. Design: Retrospective observational study. Methods: All measurements were performed by the SS-OCT biometer and the Scheimpflug topographer and using the Barrett toric formula. Results: We evaluated 122 eyes of 122 patients. The mean absolute errors in predicted residual astigmatism for the entire series were 0.41 ± 0.19 diopters (D) (0.00 to 0.85 D) using the OCT Ks and predicted PCA, 0.45 ± 0.25 D (0.00 to 1.01 D) using the OCT Ks and measured PCA, and 0.49 ± 0.25 D (0.00 to 1.30 D) using the SimKs and measured PCA. The statistically significant differences between the errors had a P value of .062 for the entire series (n = 122), .26 for the subgroup with against-the-rule astigmatism (n = 68), .47 for the subgroup with oblique astigmatism (n = 11), and .05 for the subgroup with with-the-rule astigmatism (n = 43). The percentage of eyes within ±0.50 D were 74% (n = 90), 71% (n = 87) and 64% (n = 78) (P = .13) and within ±0.75 D were 99% (n = 121), 95% (n = 116) and 84% (n = 102) (P < .001), respectively. Conclusions: The Barrett toric formula and its predicted PCA performed better with the OCT K readings than with the topographer SimKs and a measured PCA.
- 21 September 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (6) , 690-696
Open AccessPredicted vs measured posterior corneal astigmatism for toric intraocular lens calculations
Purpose: To evaluate the astigmatic correction obtained with a toric intraocular lens using the keratometric readings (Ks) from a swept-source optical coherence tomography (SS-OCT) biometer and the Barrett toric formula with its predicted posterior corneal astigmatism (PCA) value and to compare the results with those expected by using the OCT Ks and a measured PCA from a scheimpflug topographer and by using the SimKs and the measured PCA from the Scheimpflug topographer. Setting: Private practice, Lynwood, California. Design: Retrospective observational study. Methods: All measurements were performed by the SS-OCT biometer and the Scheimpflug topographer and using the Barrett toric formula. Results: We evaluated 122 eyes of 122 patients. The mean absolute errors in predicted residual astigmatism for the entire series were 0.41 ± 0.19 diopters (D) (0.00 to 0.85 D) using the OCT Ks and predicted PCA, 0.45 ± 0.25 D (0.00 to 1.01 D) using the OCT Ks and measured PCA, and 0.49 ± 0.25 D (0.00 to 1.30 D) using the SimKs and measured PCA. The statistically significant differences between the errors had a P value of .062 for the entire series (n = 122), .26 for the subgroup with against-the-rule astigmatism (n = 68), .47 for the subgroup with oblique astigmatism (n = 11), and .05 for the subgroup with with-the-rule astigmatism (n = 43). The percentage of eyes within ±0.50 D were 74% (n = 90), 71% (n = 87) and 64% (n = 78) (P = .13) and within ±0.75 D were 99% (n = 121), 95% (n = 116) and 84% (n = 102) (P < .001), respectively. Conclusions: The Barrett toric formula and its predicted PCA performed better with the OCT K readings than with the topographer SimKs and a measured PCA.
- 1 November 2015
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 41 (11) , 2379-2386
Improving the preoperative prediction of the anterior pseudophakic distance for intraocular lens power calculation
To establish a new formula for intraocular (IOL) power calculation. Private practice, Lynwood, California, USA. Retrospective observational and prospective evaluation. In this 2-part retrospective observational study followed by a prospective evaluation, the postoperative anterior pseudophakic distance (APD) was correlated with the ante-nucleus distance (AND), the nucleus thickness (NT) of the cataractous lens, and the axial length. An estimated APD (EAPD) equation was established and used prospectively in a new formula on eyes scheduled for cataract surgery. Correlations were made in 90 operated eyes, and the EAPD equation was used in a new formula on 110 eyes scheduled for cataract surgery. Using the new IOL power formula, the median absolute error was 0.28 D with 82.7% of the eyes within ±0.50 D and 100% within ±1.00 D. The new IOL power formula with its incorporated EAPD equation performed well. H.J.S. has a pending patent on this system and method for determining IOL lens power.
- 1 November 2015
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 41 (11) , 2379-2386
Improving the preoperative prediction of the anterior pseudophakic distance for intraocular lens power calculation
To establish a new formula for intraocular (IOL) power calculation. Private practice, Lynwood, California, USA. Retrospective observational and prospective evaluation. In this 2-part retrospective observational study followed by a prospective evaluation, the postoperative anterior pseudophakic distance (APD) was correlated with the ante-nucleus distance (AND), the nucleus thickness (NT) of the cataractous lens, and the axial length. An estimated APD (EAPD) equation was established and used prospectively in a new formula on eyes scheduled for cataract surgery. Correlations were made in 90 operated eyes, and the EAPD equation was used in a new formula on 110 eyes scheduled for cataract surgery. Using the new IOL power formula, the median absolute error was 0.28 D with 82.7% of the eyes within ±0.50 D and 100% within ±1.00 D. The new IOL power formula with its incorporated EAPD equation performed well. H.J.S. has a pending patent on this system and method for determining IOL lens power.
- 1 May 2013
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 39 (5) , 739-744
Intraocular lens power calculation in eyes with previous hyperopic laser in situ keratomileusis
To establish a corneal correction equation for the Shammas post-hyperopic laser in situ keratomileusis (LASIK) (Shammas-PHL) formula and to evaluate its accuracy in cases with and without available pre-LASIK data. Private practices, Lynwood, California, and Mesa, Arizona, USA. Retrospective comparative observational study. The corrected corneal power (Kc) was calculated in each eye by adding the refractive change at the corneal level to the pre-LASIK keratometric (K) readings. By comparing Kc with the measured post-LASIK K readings (Kpost), the following equation was derived: Kc = 1.0457 Kpost-1.9538. This equation was combined with the Shammas original formula to obtain the Shammas-PHL formula. The new formula was evaluated in 18 eyes with previous LASIK data and in 24 eyes with no previous LASIK data. Using the Shammas-PHL formula, the mean arithmetic prediction error was -0.03 diopter (D) ± 0.72 (SD) (range -1.57 to +1.54 D) and the median absolute error was 0.38 D in 18 eyes with available pre-LASIK data and 0.05 ± 0.58 D (range -0.56 to +1.40 D) and 0.43 D, respectively, in the 24 eyes with no pre-LASIK data. The Shammas-PHL formula can be used in post-hyperopic LASIK cases whether or not the pre-LASIK data are available.
- 1 May 2013
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 39 (5) , 739-744
Intraocular lens power calculation in eyes with previous hyperopic laser in situ keratomileusis
To establish a corneal correction equation for the Shammas post-hyperopic laser in situ keratomileusis (LASIK) (Shammas-PHL) formula and to evaluate its accuracy in cases with and without available pre-LASIK data. Private practices, Lynwood, California, and Mesa, Arizona, USA. Retrospective comparative observational study. The corrected corneal power (Kc) was calculated in each eye by adding the refractive change at the corneal level to the pre-LASIK keratometric (K) readings. By comparing Kc with the measured post-LASIK K readings (Kpost), the following equation was derived: Kc = 1.0457 Kpost-1.9538. This equation was combined with the Shammas original formula to obtain the Shammas-PHL formula. The new formula was evaluated in 18 eyes with previous LASIK data and in 24 eyes with no previous LASIK data. Using the Shammas-PHL formula, the mean arithmetic prediction error was -0.03 diopter (D) ± 0.72 (SD) (range -1.57 to +1.54 D) and the median absolute error was 0.38 D in 18 eyes with available pre-LASIK data and 0.05 ± 0.58 D (range -0.56 to +1.40 D) and 0.43 D, respectively, in the 24 eyes with no pre-LASIK data. The Shammas-PHL formula can be used in post-hyperopic LASIK cases whether or not the pre-LASIK data are available.
- 17 January 2013
- Published by Springer Nature in Current Ophthalmology Reports
- Vol. 1 (1) , 39-44
Post-LASIK IOL Power Calculations: Where Are We in 2012
- 17 January 2013
- Published by Springer Nature in Current Ophthalmology Reports
- Vol. 1 (1) , 39-44
Post-LASIK IOL Power Calculations: Where Are We in 2012