JTJulien Torbey

Julien Torbey

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Julien Torbey has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 24-Hour Intraocular Pressure Rhythms and Measurement Frequency in Glaucoma Using an Intraocular Telemetry Sensor

    by Julien Torbey, Robert N. Weinreb, Harsha L. Rao, Kaweh Mansouri

    Précis: An implantable IOP sensor study in glaucoma patients found that 5 evenly spaced daily measurements over 18 waking hours effectively reflect the 24-hour IOP rhythm, with peaks and troughs often occurring outside clinic hours. Purpose: The availability of an implantable IOP sensor enables patients to obtain IOP measurements over 24 hours and on demand. The current study assesses the optimal frequency of daily IOP measurements required to reflect the 24-hour IOP rhythm in glaucoma patients. Methods: Twenty-two patients with primary open angle glaucoma (POAG) who had previously been implanted with a sulcus-based IOP sensor (Eyemate-IO, Implandata, Germany) as part of the prospective multicentric ARGOS-02 study were enrolled. The following parameters were used to characterize the 24-hour IOP rhythm: distribution of IOP measurements and timing of IOP peaks and troughs. To assess the optimal number of IOP values to predict the 24-hour rhythm, the daily count of IOP measurements and the time interval between the first and last daily measurements were used. The correlation with the detection of daily IOP variability was assessed through Student t test and a kernel-density estimate using Gaussian kernels and Earth Movers Distance. Results: Twenty-two patients (8 female and 14 male) with a mean age of 67.8±6.8 years were followed up over 6.6±1.7 years with a total of 80,495 IOP measurements. The percentage of peak IOP values was highest (50.6%) during the early morning hours (4–5 am), while trough measurements occurred predominantly (42.3%) during the late-night hours (between 11 pm and 12 pm). Five IOP measurements equally distributed over an 18-hour period were sufficient to characterize the 24-hour rhythm. Additional measurements did not yield any statistically significant value in the characterization of 24-hour IOP patterns. Conclusions: Using an implanted telemetric sensor, the results of this study show that 5 daily IOP measurements evenly spread over 18 hours, provide sufficient information for assessment of the diurnal IOP rhythm. However, patients in practice recorded on average 4 measurements over 14 hours, highlighting the gap between the ideal recommendation and real-life adherence.


  • Repeatability of pyramidal aberrometer measurements in keratoconus and normal eyes

    by Perla Ibrahim, Jad F. Assaf, Romy Bejjani, Julien Torbey, Madeleine Yehia, Saleh Bahir Coa Al-Ulloom, Shady T. Awwad

    Purpose: To evaluate the intrasubject repeatability of pyramidal aberrometer measurements in a sample of keratoconus and normal eyes. Setting: American University of Beirut Medical Center, Beirut, Lebanon. Design: Prospective comparative repeatability analysis. Methods: Study population: Keratoconus and normal eyes from adult patients. Observation procedures: Each eye was evaluated with 3 consecutive acquisitions using a pyramidal aberrometer. Main outcome measures: The repeatability of different ocular higher-order aberrations and lower-order aberrations (HOAs and LOAs, respectively), and Zernike coefficients down to the fifth order, was evaluated. Repeatability was assessed by within-subject SDs (Sw), repeatability limits (r), and intraclass correlation coefficients (ICCs), among other parameters. Results: 72 keratoconus patients (72 eyes) and 76 normal patients (76 eyes) were included. In normal and keratoconus eyes, the ICC of total LOAs and HOAs, as well as each of the Zernike coefficients, was >0.9. The Sw for keratoconus eyes with mean maximal keratometry (Kmax) <50 diopters (D) was 0.1345 for total LOAs, 0.0619 for total HOAs, 0.0292 for horizontal coma, 0.0561 for vertical coma, and 0.0221 for spherical aberration as compared with 0.2696, 0.1486, 0.0972, 0.1497, and 0.0757 for keratoconus eyes with Kmax ≥50 D. Similar trend of better repeatability for grade 1 keratoconus and HOAs 2 D were also noted. Conclusions: Ocular aberrometer measurements generated by high definition pyramidal aberrometers have high repeatability in both normal and mild keratoconus eyes and moderate repeatability, yet still clinically acceptable, in advanced keratoconus. This is of particular importance in ocular wavefront-guided treatments.


  • Long-term results of hyperopic ablations using alcohol-assisted PRK and FS-LASIK: comparative study

    by Lara Asroui, Samuel Arba-Mosquera, Julien Torbey, Mohamad A. Ahmed, Maamoun A. Fattah, Mona Koaik, Shady T. Awwad

    Purpose: To evaluate the long-term visual and refractive outcomes of hyperopic excimer ablation using alcohol-assisted photorefractive keratectomy (PRK) and femtosecond laser–assisted laser in situ keratomileusis (FS-LASIK). Setting: American University of Beirut Medical Center, Beirut, Lebanon. Design: Retrospective, matched comparative study. Methods: Eyes that underwent alcohol-assisted PRK were compared to matched eyes that underwent FS-LASIK. All patients were followed up for at least 3 years after surgery. The refractive and visual outcomes of each group were compared at different postoperative time points. The main outcome measures were spherical equivalent deviation from target (SEDT), manifest refraction, and visual acuity. Results: 83 eyes underwent alcohol-assisted PRK and 83 matched eyes underwent FS-LASIK. Preoperative manifest refraction spherical equivalent was 2.44 ± 1.18 diopters (D) and 2.20 ± 0.87 D (P = .133) in the PRK and FS-LASIK groups, respectively. Preoperative manifest cylinder was −0.77 ± 0.89 D and −0.61 ± 0.59 D (P = .175) for the PRK and LASIK groups, respectively. 3 years postoperatively, SEDT was 0.28 ± 0.66 D and 0.40 ± 0.56 D for the PRK and LASIK groups, respectively (P = .222), whereas manifest cylinder was −0.55 ± 0.49 D and −0.30 ± 0.34 D for PRK and LASIK, respectively (P < .001). The mean difference vector was 0.59 ± 0.46 for PRK and 0.38 ± 0.32 for LASIK (P < .001). 13.3% of PRK eyes and 0% of LASIK eyes had >1 D of manifest cylinder (P = .003). Conclusions: Both alcohol-assisted PRK and FS-LASIK are safe and effective for the treatment of hyperopia. PRK induces slightly more postoperative astigmatism than LASIK. Larger optical zones and recently introduced ablation profiles that lead to a smoother ablation surface might improve the clinical results of hyperopic PRK.