Ban Leong Sng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ban Leong Sng has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
A. T. H. Sia
Department of Women's Anaesthesia KK Women's and Children's Hospital Singapore
2 shared publicationsH. S. Tan
Duke‐NUS Graduate Medical School Singapore
2 shared publicationsPryseley Nkouibert Assam
Assistant Professor Centre for Quantitative Medicine, Office of Clinical Sciences, Duke-NUS Graduate Medical School Singapore, 8 College Road, Singapore 169857; Biostatistician Singapore Clinical Research Institute Pte Ltd, 31 Biopolis Way Nanos no. 02-01, Singapore 138669
2 shared publicationsWan Ling Leong
Consultant Department of Women's Anesthesia, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore 229899
2 shared publicationsA. T. Sia
Department of Women's Anaesthesia, KK Women's and Children's Hospital, Singapore
1 shared publicationA.T. Sia
Department of Women's Anaesthesia, KK Women's and Children's Hospital, Singapore
1 shared publication
Latest Publications
- 1 June 2015
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 27 (4) , 277-284
Incidence and characteristics of breakthrough pain in parturients using computer-integrated patient-controlled epidural analgesia
- 1 June 2015
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 27 (4) , 277-284
Incidence and characteristics of breakthrough pain in parturients using computer-integrated patient-controlled epidural analgesia
- 28 January 2015
- Published by Wiley in Anaesthesia
- Vol. 70 (6) , 691-698
Assessment of an updated double‐vasopressor automated system using Nexfin ™ for the maintenance of haemodynamic stability to improve peri‐operative outcome during spinal anaesthesia for caesarean section
Summary: Hypotension occurs commonly during spinal anaesthesia for caesarean section, associated with maternal and fetal adverse effects. We developed a double‐vasopressor automated system with a two‐step algorithm and continuous non‐invasive haemodynamic monitoring using the Nexfin ™ device. The system delivered 25 μg phenylephrine every 30 s when systolic blood pressure was between 90% and 100% of baseline, or 2 mg ephedrine at this blood pressure range and heart rate < 60 beats.min −1 ; and 50 μg phenylephrine or 4 mg ephedrine when systolic blood pressure was < 90% of baseline with the same heart rate criterion. Fifty‐seven women received standardised spinal anaesthesia. Twenty‐seven (47.4%) had at least one reading of hypotension defined as systolic blood pressure < 80% baseline. Systolic blood pressure was within 20% of the baseline in a mean ( SD ) of 79.8 (20.9)% of measurements. Fifty‐three (93.0%) women required phenylephrine before delivery while 10 (17.5%) required ephedrine. Six women (10.5%) experienced nausea and three (5.3%) vomited. The system was able to achieve a low incidence of maternal hypotension with good maternal and fetal outcomes.
- 28 January 2015
- Published by Wiley in Anaesthesia
- Vol. 70 (6) , 691-698
Assessment of an updated double‐vasopressor automated system using Nexfin ™ for the maintenance of haemodynamic stability to improve peri‐operative outcome during spinal anaesthesia for caesarean section
Summary: Hypotension occurs commonly during spinal anaesthesia for caesarean section, associated with maternal and fetal adverse effects. We developed a double‐vasopressor automated system with a two‐step algorithm and continuous non‐invasive haemodynamic monitoring using the Nexfin ™ device. The system delivered 25 μg phenylephrine every 30 s when systolic blood pressure was between 90% and 100% of baseline, or 2 mg ephedrine at this blood pressure range and heart rate < 60 beats.min −1 ; and 50 μg phenylephrine or 4 mg ephedrine when systolic blood pressure was < 90% of baseline with the same heart rate criterion. Fifty‐seven women received standardised spinal anaesthesia. Twenty‐seven (47.4%) had at least one reading of hypotension defined as systolic blood pressure < 80% baseline. Systolic blood pressure was within 20% of the baseline in a mean ( SD ) of 79.8 (20.9)% of measurements. Fifty‐three (93.0%) women required phenylephrine before delivery while 10 (17.5%) required ephedrine. Six women (10.5%) experienced nausea and three (5.3%) vomited. The system was able to achieve a low incidence of maternal hypotension with good maternal and fetal outcomes.
- 1 May 2014
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 23 (2) , 196-198
Novel vital signs-controlled, patient-assisted intravenous analgesia using remifentanil for labour and delivery
- 1 May 2014
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 23 (2) , 196-198
Novel vital signs-controlled, patient-assisted intravenous analgesia using remifentanil for labour and delivery
- Open Access
- 1 January 2014
- Published by Medknow in Journal of Anaesthesiology Clinical Pharmacology
- Vol. 30 (4) , 496-501
Comparison of computer-integrated patient-controlled epidural analgesia with no initial basal infusion versus moderate basal infusion for labor and delivery : A randomized controlled trial
Background and Aims: Computer-integrated patient-controlled epidural analgesia (CIPCEA) is a novel epidural drug delivery system. It automatically adjusts the basal infusion based on the individual's need for analgesia as labor progresses. Materials and Methods: This study compared the time-weighted local anesthetic (LA) consumption by comparing parturients using CIPCEA with no initial basal infusion (CIPCEA0) with CIPCEA with initial moderate basal infusion of 5 ml/H (CIPCEA5). We recruited 76 subjects after ethics approval. The computer integration of CIPCEA titrate the basal infusion to 5, 10, 15, or 20 ml/H if the parturient required respectively, one, two, three, or four patient demands in the previous hour. The basal infusion reduced by 5 ml/H if there was no demand in the previous hour. The sample size was calculated to show equivalence in LA consumption. Results: The time-weighted LA consumption between both groups were similar with CIPCEA0 group (mean [standard deviation (SD)] 8.9 [3.5] mg/H) compared to the CIPCEA5 group (mean [SD] 9.9 [3.5] mg/H), P = 0.080. Both groups had a similar incidence of breakthrough pain, duration of the second stage, mode of delivery, and patient satisfaction. However, more subjects in the CIPCEA0 group required patient self-bolus. There were no differences in fetal outcomes. Discussion: Both CIPCEA regimens had similar time-weighted LA consumption and initial moderate basal infusion with CIPCEA may not be required.
- 1 January 2014
- Published by Medknow in Journal of Anaesthesiology Clinical Pharmacology
- Vol. 30 (4) , 496-501
Open AccessComparison of computer-integrated patient-controlled epidural analgesia with no initial basal infusion versus moderate basal infusion for labor and delivery : A randomized controlled trial
Background and Aims: Computer-integrated patient-controlled epidural analgesia (CIPCEA) is a novel epidural drug delivery system. It automatically adjusts the basal infusion based on the individual's need for analgesia as labor progresses. Materials and Methods: This study compared the time-weighted local anesthetic (LA) consumption by comparing parturients using CIPCEA with no initial basal infusion (CIPCEA0) with CIPCEA with initial moderate basal infusion of 5 ml/H (CIPCEA5). We recruited 76 subjects after ethics approval. The computer integration of CIPCEA titrate the basal infusion to 5, 10, 15, or 20 ml/H if the parturient required respectively, one, two, three, or four patient demands in the previous hour. The basal infusion reduced by 5 ml/H if there was no demand in the previous hour. The sample size was calculated to show equivalence in LA consumption. Results: The time-weighted LA consumption between both groups were similar with CIPCEA0 group (mean [standard deviation (SD)] 8.9 [3.5] mg/H) compared to the CIPCEA5 group (mean [SD] 9.9 [3.5] mg/H), P = 0.080. Both groups had a similar incidence of breakthrough pain, duration of the second stage, mode of delivery, and patient satisfaction. However, more subjects in the CIPCEA0 group required patient self-bolus. There were no differences in fetal outcomes. Discussion: Both CIPCEA regimens had similar time-weighted LA consumption and initial moderate basal infusion with CIPCEA may not be required.
- 20 November 2013
- Published by Wiley in Anaesthesia
- Vol. 69 (1) , 37-45
Closed‐loop double‐vasopressor automated system vs manual bolus vasopressor to treat hypotension during spinal anaesthesia for caesarean section: a randomised controlled trial
Summary: Hypotension necessitating vasopressor administration occurs commonly during caesarean section under spinal anaesthesia. We developed a novel vasopressor delivery system that automatically administers phenylephrine or ephedrine based on continuous non‐invasive arterial pressure monitoring. A phenylephrine bolus of 50 μg was given at 30‐s intervals when systolic blood pressure fell < 90% of baseline; an ephedrine bolus of 4 mg was given instead if systolic pressure fell < 90% of baseline together with a heart rate < 60 beats.min −1 . The control group used manual boluses of either phenylephrine 100 μg or ephedrine 8 mg, administered at 1‐min intervals based on the same thresholds for systolic pressure and heart rate. This randomised, controlled, double‐blinded trial involved 213 healthy women who underwent elective caesarean delivery under spinal anaesthesia using 11 mg hyperbaric bupivacaine with 15 μg fentanyl and 100 μg morphine. The automated vasopressor group had better systolic pressure control, with 37/106 (34.9%) having any beat‐to‐beat systolic pressure reading < 80% of baseline compared with 63/107 (58.9%) in the control group (p < 0.001). There was no difference in the incidence of reactive hypertension, defined as systolic pressure > 120% of baseline, with 8/106 (7.5%) in the automated vasopressor group vs 14/107 (13.1%) in the control group, or total dose of vasopressors. The automated vasopressor group had lower median absolute performance error of 8.5% vs control of 9.8% (p = 0.013), and reduced incidence of nausea (1/106 (0.9%) vs 11/107 (10.3%), p = 0.005). Neonatal umbilical cord pH, umbilical lactate and Apgar scores were similar. Hence, our system afforded better control of maternal blood pressure and reduced nausea with no increase in reactive hypertension when compared with manual boluses.
- 20 November 2013
- Published by Wiley in Anaesthesia
- Vol. 69 (1) , 37-45
Closed‐loop double‐vasopressor automated system vs manual bolus vasopressor to treat hypotension during spinal anaesthesia for caesarean section: a randomised controlled trial
Summary: Hypotension necessitating vasopressor administration occurs commonly during caesarean section under spinal anaesthesia. We developed a novel vasopressor delivery system that automatically administers phenylephrine or ephedrine based on continuous non‐invasive arterial pressure monitoring. A phenylephrine bolus of 50 μg was given at 30‐s intervals when systolic blood pressure fell < 90% of baseline; an ephedrine bolus of 4 mg was given instead if systolic pressure fell < 90% of baseline together with a heart rate < 60 beats.min −1 . The control group used manual boluses of either phenylephrine 100 μg or ephedrine 8 mg, administered at 1‐min intervals based on the same thresholds for systolic pressure and heart rate. This randomised, controlled, double‐blinded trial involved 213 healthy women who underwent elective caesarean delivery under spinal anaesthesia using 11 mg hyperbaric bupivacaine with 15 μg fentanyl and 100 μg morphine. The automated vasopressor group had better systolic pressure control, with 37/106 (34.9%) having any beat‐to‐beat systolic pressure reading < 80% of baseline compared with 63/107 (58.9%) in the control group (p < 0.001). There was no difference in the incidence of reactive hypertension, defined as systolic pressure > 120% of baseline, with 8/106 (7.5%) in the automated vasopressor group vs 14/107 (13.1%) in the control group, or total dose of vasopressors. The automated vasopressor group had lower median absolute performance error of 8.5% vs control of 9.8% (p = 0.013), and reduced incidence of nausea (1/106 (0.9%) vs 11/107 (10.3%), p = 0.005). Neonatal umbilical cord pH, umbilical lactate and Apgar scores were similar. Hence, our system afforded better control of maternal blood pressure and reduced nausea with no increase in reactive hypertension when compared with manual boluses.
- 28 September 2012
- Published by Wiley in Anaesthesia
- Vol. 67 (12) , 1348-1355
Closed‐loop double‐vasopressor automated system to treat hypotension during spinal anaesthesia for caesarean section: a preliminary study
Summary: Hypotension occurs in most caesarean sections under spinal anaesthesia, necessitating vasopressor administration. However, the optimal dosing regimen remains unclear. We have developed a novel vasopressor delivery system that automatically administers phenylephrine or ephedrine based on continuous non‐invasive blood pressure monitoring. This prospective cohort study recruited 55 healthy women under standardised spinal anaesthesia with 2.2 ml hyperbaric bupivacaine 0.5%, 15 μg fentanyl and 100 μg morphine. A 50‐μg phenylephrine bolus was given at 1‐min intervals when systolic blood pressure fell below 90% of baseline, and a 4‐mg ephedrine bolus was given when hypotension developed with bradycardia (heart rate −1 ). Systolic blood pressure was within 20% of baseline in 88% of all measurements. Six patients (11%) had one or more measurements above 120% of baseline (1% of all measurements), whereas 36 (65%) had at least one reading below 80% of baseline (11% of total measurements). The system maintained systolic blood pressure at a mean (SD) of −9.1 (7.0)% below baseline, with 5.4 (2.5)% fluctuation. Two patients (4%) experienced pre‐delivery nausea. All 5‐min Apgar scores were 9.
- 28 September 2012
- Published by Wiley in Anaesthesia
- Vol. 67 (12) , 1348-1355
Closed‐loop double‐vasopressor automated system to treat hypotension during spinal anaesthesia for caesarean section: a preliminary study
Summary: Hypotension occurs in most caesarean sections under spinal anaesthesia, necessitating vasopressor administration. However, the optimal dosing regimen remains unclear. We have developed a novel vasopressor delivery system that automatically administers phenylephrine or ephedrine based on continuous non‐invasive blood pressure monitoring. This prospective cohort study recruited 55 healthy women under standardised spinal anaesthesia with 2.2 ml hyperbaric bupivacaine 0.5%, 15 μg fentanyl and 100 μg morphine. A 50‐μg phenylephrine bolus was given at 1‐min intervals when systolic blood pressure fell below 90% of baseline, and a 4‐mg ephedrine bolus was given when hypotension developed with bradycardia (heart rate −1 ). Systolic blood pressure was within 20% of baseline in 88% of all measurements. Six patients (11%) had one or more measurements above 120% of baseline (1% of all measurements), whereas 36 (65%) had at least one reading below 80% of baseline (11% of total measurements). The system maintained systolic blood pressure at a mean (SD) of −9.1 (7.0)% below baseline, with 5.4 (2.5)% fluctuation. Two patients (4%) experienced pre‐delivery nausea. All 5‐min Apgar scores were 9.