HTHéctor Toledo

Héctor Toledo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Héctor Toledo has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • A. Pulido

    Servicio de Microbiología, UCEIMP. Hospital Universitario Virgen del Rocío. Sevilla

    1 shared publication
  • Alberto De La Iglesia Salgado

    Clinical Laboratory Department, Hospital Comarcal Infanta Elena , Huelva , Spain

    1 shared publication
  • C. Cabezas

    Unidad de Gestión Clínica de Urgencias Pediátricas. Hospital Universitario Virgen del Rocío. Sevilla

    1 shared publication
  • E. Ciorata

    Servicio de Microbiología, UCEIMP. Hospital Universitario Virgen del Rocío. Sevilla

    1 shared publication
  • Guillermo Martín-Gutiérrez

    Servicio de Microbiología Hospital Universitario Virgen del Rocío de Sevilla, Seville, Spain

    1 shared publication
  • Inmaculada García Borrero

    Clinical Laboratory Department, Hospital Comarcal Infanta Elena , Huelva , Spain

    1 shared publication

Latest Publications

  • Open Access

    Validez de la tinción de Gram en el diagnóstico de infecciones del tracto urinario en pacientes pediátricos

    by J.A. Pérez Cáceres, Héctor Toledo, A. Pulido, E. Ciorata, Á. Hurtado, C. Cabezas, J.A. Lepe

    Introducción. El diagnóstico de la infección del tracto urinario (ITU) en lactantes sigue siendo controvertido. Aunque la tinción de Gram se utiliza habitualmente, existen pocos estudios que evalúen su efectividad en el diagnóstico clínico de la ITU. Objetivos. Evaluar la validez de la tinción de Gram en el diagnóstico de la ITU. Materiales y métodos. Se analizaron muestras de orina de 510 pacientes pediátricos con sospecha de ITU atendidos en el Servicio de Emergencias Pediátricas, mediante urocultivo y tinción de Gram. Además, a 397 pacientes se les realizó una TR. La edad de los pacientes varió entre 3 meses y 17 años, con 427 niños menores de 3 meses y 83 mayores de 3 meses. Resultados. De los cultivos realizados, 154 fueron positivos, 335 negativos y 21 contaminados. La tinción de Gram presentó una sensibilidad del 90,3% (IC95: 84,2-94,3%) y una especificidad del 93,1% (IC95: 89,7- 95,5%). El cociente de probabilidad negativo combinado entre la tinción de Gram y la TR fue de 0,003, con una probabilidad post-prueba negativa del 0,1% en el escenario de fiebre sin foco. Conclusiones. La tinción de Gram, especialmente combinada con la TR, es la prueba diagnóstica más eficaz para la ITU en situaciones de urgencia, debido a sus altos valores de concordancia con el urocultivo y su cociente de probabilidad positivo. Una tinción de Gram negativa por sí sola no descarta la ITU, pero la combinación de una TR negativa y un Gram negativo permite excluir la infección en el entorno de emergencia.

  • Open Access

    Advantages of Syndromic Diagnostics: Detection of the Pathogens Causing Urethritis/Cervicitis with the STI CNM Real-Time PCR Kit from Vitro S.A.

    by Miguel Ángel Castaño López, Héctor Toledo Porteros, Alberto De La Iglesia Salgado, Josefa Vazquez Medel, Inmaculada García Borrero

    The STI CNM Real-Time PCR Kit from Vitro S.A. (Spain) demonstrates high sensitivity and specificity, is cost-effective, and can detect the three main etiological agents of urethritis/cervicitis in a single multiplex PCR. Sexually transmitted infections (STIs) are a significant public health problem and a significant burden of morbidity and mortality in hospitals. The World Health Organization (WHO) estimates the number of daily infections to be 1 million. Currently, the number of infections and antimicrobial-resistant strains is rising. A rapid and accurate etiologic diagnosis is critical to solving this problem. In this study, we compared the STI CNM Real-Time PCR Kit using the Xpert® CT/NG technique (Cepheid®, USA) as Gold Standard for the diagnosis of Chlamydia trachomatis and Neisseria gonorrhoeae and EasyNAT® MG (Ustar Biotechnologies (Hangzhou) Ltd., China) as Gold Standard for the diagnosis of Mycoplasma genitalium infection. Regarding C. trachomatis and N. gonorrhoeae, out of 200 samples, there was a match in 199 cases, with only one positive sample not being detected by the STI CNM Real-Time PCR Kit. This results in a sensitivity of 96% and a specificity of 100% for this kit. Diagnosing M. genitalium infection, out of 200 samples, the STI CNM Real-Time PCR Kit correctly detected all negative and positive samples, with 100% agreement compared to the reference technique. In summary, the STI assay has a very high sensitivity and specificity, comparable to other commercial diagnostic kits. Furthermore, it has the advantage of bundling the detection of the three main bacterial agents of urethritis/cervicitis, resulting in better cost efficiency.


  • Usefulness of UF-5000 automatic screening system in UTI diagnosis

    by Héctor Toledo, Sara G. Punzón, Guillermo Martín-Gutiérrez, Juan A. Pérez, José A. Lepe

    We have evaluated the Sysmex UF-5000 cytometer use in microbiology for the screening of negative urines, looking for cut-off points to detect bacteria and leukocytes. The number of processed urines was 3569, the highest to date in these studies. The best general cut-off point has been 100 bact/μl, giving an area under the ROC curve of 0.868, a sensitivity of 96%, a specificity of 50%, 1.17% of false negatives, and saving 40% of cultures. The PPV and NPV have been 35.5 and 95.4 respectively. The leukocyte count has not been useful. Finally, we have evaluated urine screening usefulness, concluding that in laboratories such as ours (284 urines/working day) or smaller, it is not cost-effective.