Wouter Daniel Maathuis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wouter Daniel Maathuis has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Abdallah H. A. Zaid Al-Kaylani
Department of Radiology, Medical Imaging Center, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
1 shared publication Alexander Leemans
Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
1 shared publicationBachtiar Burhani
Department of Neurosurgery, St. Elisabeth Hospital, Tilburg, The Netherlands
1 shared publicationEduard H. Voormolen
Department of Neurology and Neurosurgery, University Medical Center Utrecht, Utrecht, The Netherlands
1 shared publication- Eelco Wieger Hoving
Princess Maxima Center for Pediatric Oncology, Utrecht, The Netherlands
1 shared publication - Elisa Colombo
Department of Neurosurgery, Clinical Neuroscience Center, University Hospital Zurich, 8091 Zurich, Switzerland
1 shared publication
Latest Publications
- Open Access
- 25 February 2026
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Reports
- Vol. 87 (02) , e71-e76
Intraoperative Evaluation of Semiautomatic Localization of the Facial Nerve Using Diffusion Tensor Imaging in Patients with Large Vestibular Schwannomas: A Pilot Study
Facial nerve damage remains a significant risk during vestibular schwannoma (VS) resection, with reported incidences varying widely (3–46%). Damage risk increases with tumor size. Digital tractography enables nerve reconstruction but typically involves manual procedures, resulting in subjective evaluations that limit reproducibility and validation. We introduce a robust, semi-automatic tractography methodology with reproducible region-of-interest (ROI) generation and present an initial validation using a novel quantitative three-dimensional comparison approach in patients with a large VS. To assess the accuracy of facial nerve reconstruction employing a semi-automatic ROI selection method in patients with VSs. We included six patients with an average tumor size of 28 mm (95% CI: 17–40, 100% left) who underwent translabyrinthine VS surgery. Each VS patient was scanned with the regular neuronavigation magnetic resonance imaging (MRI) protocol and a custom diffusion-MRI protocol before surgery. The facial nerve trajectory was reconstructed with a diffusion tensor imaging-based tractography software package using semi-automatic ROI generation. We validated our reconstructions with the Brainlab neuronavigation system for intraoperative point annotation along the course of the facial nerve. Tracts could be reconstructed in all included patients. The median distance and angle between the points and closest reconstruction were 5.1 mm (IQR: 3.5–7.6) and 38.5 degrees (IQR: 2.7–79.8), respectively. We present a promising methodology for facial nerve reconstruction in patients with VSs. However, further optimization of the methodology is warranted before a proper clinical validation study can be performed.
- 25 February 2026
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Reports
- Vol. 87 (02) , e71-e76
Open AccessIntraoperative Evaluation of Semiautomatic Localization of the Facial Nerve Using Diffusion Tensor Imaging in Patients with Large Vestibular Schwannomas: A Pilot Study
Facial nerve damage remains a significant risk during vestibular schwannoma (VS) resection, with reported incidences varying widely (3–46%). Damage risk increases with tumor size. Digital tractography enables nerve reconstruction but typically involves manual procedures, resulting in subjective evaluations that limit reproducibility and validation. We introduce a robust, semi-automatic tractography methodology with reproducible region-of-interest (ROI) generation and present an initial validation using a novel quantitative three-dimensional comparison approach in patients with a large VS. To assess the accuracy of facial nerve reconstruction employing a semi-automatic ROI selection method in patients with VSs. We included six patients with an average tumor size of 28 mm (95% CI: 17–40, 100% left) who underwent translabyrinthine VS surgery. Each VS patient was scanned with the regular neuronavigation magnetic resonance imaging (MRI) protocol and a custom diffusion-MRI protocol before surgery. The facial nerve trajectory was reconstructed with a diffusion tensor imaging-based tractography software package using semi-automatic ROI generation. We validated our reconstructions with the Brainlab neuronavigation system for intraoperative point annotation along the course of the facial nerve. Tracts could be reconstructed in all included patients. The median distance and angle between the points and closest reconstruction were 5.1 mm (IQR: 3.5–7.6) and 38.5 degrees (IQR: 2.7–79.8), respectively. We present a promising methodology for facial nerve reconstruction in patients with VSs. However, further optimization of the methodology is warranted before a proper clinical validation study can be performed.
- Open Access
- 24 December 2025
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 167 (1)
Comparing augmented reality-assisted and freehand external ventricular drain placement: a multicenter randomized controlled crossover phantom study
Background: External ventricular drain (EVD) placement is a common neurosurgical procedure with high rates of misplacement when performed using the freehand technique. With augmented reality (AR), the accuracy of EVD placement could be improved by providing a 3-D overlay, guiding optimal placement using a virtual trajectory superimposed over the patient. In this study, we aimed to assess the efficacy and usability of an AR application for assisting EVD placements which supported trajectory planning, point-based image-to-patient registration and 3-D stereoscopic projection. Method: We conducted a randomized controlled crossover trial involving 15 neurosurgical residents and one neurosurgeon, who performed 236 EVD procedures (118 AR-assisted and 118 freehand) on biomimetic phantoms. EVD placement accuracy was evaluated using the Kakarla scale, distance-to-target, angular inaccuracy, and depth inaccuracy. The total procedural time was recorded. The user experience was evaluated using the NASA Task Load Index (NASA-TLX) and the Usefulness, Satisfaction, and Ease of Use (USE) questionnaire. Results: AR-assisted placement achieved significantly higher rates of optimal placement (Kakarla grade 1: 57.6% vs 37.3%; p < .001), lower rates of erroneous placement (Kakarla grade 3: 21.2% vs 40.7%; p < .001), a lower distance-to-target (median, 7.2 mm vs 11.4 mm; p < .001) and lower angular inaccuracy (median, 5.58° vs 7.60°; p < .001). Procedural time was longer for AR (median, 7 min 30 s vs 1 min 11 s; p < .001). Participants rated the AR system favorably on the USE for ease of learning (mean, 6.09/7 [SD, 0.94]) and satisfaction (mean, 6.45/7 [SD, 0.69]), while NASA-TLX scores indicated similar workloads between AR and freehand techniques. Conclusions: AR improves the accuracy of EVD placement compared to the freehand technique, which is expected to improve the efficacy in clinical settings. It increases total procedural time but remains within clinically acceptable limits and provides favorable usability.
- 24 December 2025
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 167 (1)
Open AccessComparing augmented reality-assisted and freehand external ventricular drain placement: a multicenter randomized controlled crossover phantom study
Background: External ventricular drain (EVD) placement is a common neurosurgical procedure with high rates of misplacement when performed using the freehand technique. With augmented reality (AR), the accuracy of EVD placement could be improved by providing a 3-D overlay, guiding optimal placement using a virtual trajectory superimposed over the patient. In this study, we aimed to assess the efficacy and usability of an AR application for assisting EVD placements which supported trajectory planning, point-based image-to-patient registration and 3-D stereoscopic projection. Method: We conducted a randomized controlled crossover trial involving 15 neurosurgical residents and one neurosurgeon, who performed 236 EVD procedures (118 AR-assisted and 118 freehand) on biomimetic phantoms. EVD placement accuracy was evaluated using the Kakarla scale, distance-to-target, angular inaccuracy, and depth inaccuracy. The total procedural time was recorded. The user experience was evaluated using the NASA Task Load Index (NASA-TLX) and the Usefulness, Satisfaction, and Ease of Use (USE) questionnaire. Results: AR-assisted placement achieved significantly higher rates of optimal placement (Kakarla grade 1: 57.6% vs 37.3%; p < .001), lower rates of erroneous placement (Kakarla grade 3: 21.2% vs 40.7%; p < .001), a lower distance-to-target (median, 7.2 mm vs 11.4 mm; p < .001) and lower angular inaccuracy (median, 5.58° vs 7.60°; p < .001). Procedural time was longer for AR (median, 7 min 30 s vs 1 min 11 s; p < .001). Participants rated the AR system favorably on the USE for ease of learning (mean, 6.09/7 [SD, 0.94]) and satisfaction (mean, 6.45/7 [SD, 0.69]), while NASA-TLX scores indicated similar workloads between AR and freehand techniques. Conclusions: AR improves the accuracy of EVD placement compared to the freehand technique, which is expected to improve the efficacy in clinical settings. It increases total procedural time but remains within clinically acceptable limits and provides favorable usability.
- 6 July 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (8) , 922-927
Clinical Applications of Conebeam CTP Imaging in Cerebral Disease: A Systematic Review
BACKGROUND: Perfusion imaging with multidetector CT is integral to the evaluation of patients presenting with ischemic stroke due to large-vessel occlusion. Using conebeam CT perfusion in a direct-to-angio approach could reduce workflow times and improve functional outcome. PURPOSE: Our aim was to provide an overview of conebeam CT techniques for quantifying cerebral perfusion, their clinical applications, and validation. DATA SOURCES: A systematic search was performed for articles published between January 2000 and October 2022 in which a conebeam CT imaging technique for quantifying cerebral perfusion in human subjects was compared against a reference technique. STUDY SELECTION: Eleven articles were retrieved describing 2 techniques: dual-phase (n = 6) and multiphase (n = 5) conebeam CTP. DATA ANALYSIS: Descriptions of the conebeam CT techniques and the correlations between them and the reference techniques were retrieved. DATA SYNTHESIS: Appraisal of the quality and risk of bias of the included studies revealed little concern about bias and applicability. Good correlations were reported for dual-phase conebeam CTP; however, the comprehensiveness of its parameter is unclear. Multiphase conebeam CTP demonstrated the potential for clinical implementation due to its ability to produce conventional stroke protocols. However, it did not consistently correlate with the reference techniques. LIMITATIONS: The heterogeneity within the available literature made it impossible to apply meta-analysis to the data. CONCLUSIONS: The reviewed techniques show promise for clinical use. Beyond evaluating their diagnostic accuracy, future studies should address the practical challenges associated with implementing these techniques and the potential benefits for different ischemic diseases.
- 6 July 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (8) , 922-927
Clinical Applications of Conebeam CTP Imaging in Cerebral Disease: A Systematic Review
BACKGROUND: Perfusion imaging with multidetector CT is integral to the evaluation of patients presenting with ischemic stroke due to large-vessel occlusion. Using conebeam CT perfusion in a direct-to-angio approach could reduce workflow times and improve functional outcome. PURPOSE: Our aim was to provide an overview of conebeam CT techniques for quantifying cerebral perfusion, their clinical applications, and validation. DATA SOURCES: A systematic search was performed for articles published between January 2000 and October 2022 in which a conebeam CT imaging technique for quantifying cerebral perfusion in human subjects was compared against a reference technique. STUDY SELECTION: Eleven articles were retrieved describing 2 techniques: dual-phase (n = 6) and multiphase (n = 5) conebeam CTP. DATA ANALYSIS: Descriptions of the conebeam CT techniques and the correlations between them and the reference techniques were retrieved. DATA SYNTHESIS: Appraisal of the quality and risk of bias of the included studies revealed little concern about bias and applicability. Good correlations were reported for dual-phase conebeam CTP; however, the comprehensiveness of its parameter is unclear. Multiphase conebeam CTP demonstrated the potential for clinical implementation due to its ability to produce conventional stroke protocols. However, it did not consistently correlate with the reference techniques. LIMITATIONS: The heterogeneity within the available literature made it impossible to apply meta-analysis to the data. CONCLUSIONS: The reviewed techniques show promise for clinical use. Beyond evaluating their diagnostic accuracy, future studies should address the practical challenges associated with implementing these techniques and the potential benefits for different ischemic diseases.