Comparing augmented reality-assisted and freehand external ventricular drain placement: a multicenter randomized controlled crossover phantom study
Authors:
- Jesse A. M. van DoormaalJDJesse A. M. van Doormaal
- Elisa ColomboECElisa Colombo
- Jasper M. van der ZeeJZJasper M. van der Zee
- Wouter D. MaathuisWMWouter D. Maathuis
- Maarten BotMBMaarten Bot
- Luca RegliLRLuca Regli
- Pierre A. J. T. RobePRPierre A. J. T. Robe
- Eelco W. HovingEHEelco W. Hoving
- Tristan P. C. van DoormaalTDTristan P. C. van Doormaal
Open Access
- 24 December 2025
- journal article
- research article
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 167 (1)
Abstract
Background: External ventricular drain (EVD) placement is a common neurosurgical procedure with high rates of misplacement when performed using the freehand technique. With augmented reality (AR), the accuracy of EVD placement could be improved by providing a 3-D overlay, guiding optimal placement using a virtual trajectory superimposed over the patient. In this study, we aimed to assess the efficacy and usability of an AR application for assisting EVD placements which supported trajectory planning, point-based image-to-patient registration and 3-D stereoscopic projection. Method: We conducted a randomized controlled crossover trial involving 15 neurosurgical residents and one neurosurgeon, who performed 236 EVD procedures (118 AR-assisted and 118 freehand) on biomimetic phantoms. EVD placement accuracy was evaluated using the Kakarla scale, distance-to-target, angular inaccuracy, and depth inaccuracy. The total procedural time was recorded. The user experience was evaluated using the NASA Task Load Index (NASA-TLX) and the Usefulness, Satisfaction, and Ease of Use (USE) questionnaire. Results: AR-assisted placement achieved significantly higher rates of optimal placement (Kakarla grade 1: 57.6% vs 37.3%; p < .001), lower rates of erroneous placement (Kakarla grade 3: 21.2% vs 40.7%; p < .001), a lower distance-to-target (median, 7.2 mm vs 11.4 mm; p < .001) and lower angular inaccuracy (median, 5.58° vs 7.60°; p < .001). Procedural time was longer for AR (median, 7 min 30 s vs 1 min 11 s; p < .001). Participants rated the AR system favorably on the USE for ease of learning (mean, 6.09/7 [SD, 0.94]) and satisfaction (mean, 6.45/7 [SD, 0.69]), while NASA-TLX scores indicated similar workloads between AR and freehand techniques. Conclusions: AR improves the accuracy of EVD placement compared to the freehand technique, which is expected to improve the efficacy in clinical settings. It increases total procedural time but remains within clinically acceptable limits and provides favorable usability.Keywords
Funding Information
- HORIZON EUROPE Framework Programme (190106553)
This publication has 46 references indexed in Scilit:
- NnU-Net versus mesh growing algorithm as a tool for the robust and timely segmentation of neurosurgical 3D images in contrast-enhanced T1 MRI scansActa Neurochirurgica, 2024
- External ventricular drains and risk of freehand placement: A systematic review and meta-analysisClinical Neurology and Neurosurgery, 2023
- Augmented and virtual reality usage in awake craniotomy: a systematic reviewNeurosurgical Review, 2022
- Current status of augmented reality in cerebrovascular surgery: a systematic reviewNeurosurgical Review, 2022
- Systematic review and meta-analysis of external ventricular drain placement accuracy and narrative review of guidance devicesJournal of Clinical Neuroscience, 2021
- Accuracy and complication rates of external ventricular drain placement with twist drill and bolt system versus standard trephine and tunnelation: a retrospective population-based studyActa Neurochirurgica, 2020
- Virtual reality and augmented reality in the management of intracranial tumors: A reviewJournal of Clinical Neuroscience, 2019
- External ventricular drain placement in the intensive care unit versus operating room: Evaluation of complications and accuracyClinical Neurology and Neurosurgery, 2015
- 3D Slicer: A Platform for Subject-Specific Image Analysis, Visualization, and Clinical Support2013
- AN ENCEPHALOGRAPHIC RATIO FOR ESTIMATING VENTRICULAR ENLARGEMENT AND CEREBRAL ATROPHYArchives of Neurology And Psychiatry, 1942