Yida Xiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yida Xiang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Binbing Wang
Zhejiang Cancer Hospital, Hangzhou, China
1 shared publication - Jie Zhang
Department of Radiation Physics Zhejiang Cancer Hospital Hangzhou Zhejiang China
1 shared publication - Qing Hou
Key Laboratory of Radiation Physics and Technology of the Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University 1 , Chengdu 610064
1 shared publication - Shengye Wang
Chinese Acad Sci, Inst Basic Med & Canc IBMC, Zhejiang Canc Hosp, Dept Radiat Phys,Canc Hosp,Univ Chinese Acad Sci, Hangzhou 310022, Zhejiang, Peoples R China
1 shared publication - Xue Bai
Zhejiang Cancer Hospital, Hangzhou, China
1 shared publication
Latest Publications
- Open Access
- 9 October 2021
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 20 (1) , 1-15
Sharp loss: a new loss function for radiotherapy dose prediction based on fully convolutional networks
Background: Neural-network methods have been widely used for the prediction of dose distributions in radiotherapy. However, the prediction accuracy of existing methods may be degraded by the problem of dose imbalance. In this work, a new loss function is proposed to alleviate the dose imbalance and achieve more accurate prediction results. The U-Net architecture was employed to build a prediction model. Our study involved a total of 110 patients with left-breast cancer, who were previously treated by volumetric-modulated arc radiotherapy. The patient dataset was divided into training and test subsets of 100 and 10 cases, respectively. We proposed a novel ‘sharp loss’ function, and a parameter γ was used to adjust the loss properties. The mean square error (MSE) loss and the sharp loss with different γ values were tested and compared using the Wilcoxon signed-rank test. Results: The sharp loss achieved superior dose prediction results compared to those of the MSE loss. The best performance with the MSE loss and the sharp loss was obtained when the parameter γ was set to 100. Specifically, the mean absolute difference values for the planning target volume were 318.87 ± 30.23 for the MSE loss versus 144.15 ± 16.27 for the sharp loss with γ = 100 (p < 0.05). The corresponding values for the ipsilateral lung, the heart, the contralateral lung, and the spinal cord were 278.99 ± 51.68 versus 198.75 ± 61.38 (p < 0.05), 216.99 ± 44.13 versus 144.86 ± 43.98 (p < 0.05), 125.96 ± 66.76 versus 111.86 ± 47.19 (p > 0.05), and 194.30 ± 14.51 versus 168.58 ± 25.97 (p < 0.05), respectively. Conclusions: The sharp loss function could significantly improve the accuracy of radiotherapy dose prediction.
- 9 October 2021
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 20 (1) , 1-15
Open AccessSharp loss: a new loss function for radiotherapy dose prediction based on fully convolutional networks
Background: Neural-network methods have been widely used for the prediction of dose distributions in radiotherapy. However, the prediction accuracy of existing methods may be degraded by the problem of dose imbalance. In this work, a new loss function is proposed to alleviate the dose imbalance and achieve more accurate prediction results. The U-Net architecture was employed to build a prediction model. Our study involved a total of 110 patients with left-breast cancer, who were previously treated by volumetric-modulated arc radiotherapy. The patient dataset was divided into training and test subsets of 100 and 10 cases, respectively. We proposed a novel ‘sharp loss’ function, and a parameter γ was used to adjust the loss properties. The mean square error (MSE) loss and the sharp loss with different γ values were tested and compared using the Wilcoxon signed-rank test. Results: The sharp loss achieved superior dose prediction results compared to those of the MSE loss. The best performance with the MSE loss and the sharp loss was obtained when the parameter γ was set to 100. Specifically, the mean absolute difference values for the planning target volume were 318.87 ± 30.23 for the MSE loss versus 144.15 ± 16.27 for the sharp loss with γ = 100 (p < 0.05). The corresponding values for the ipsilateral lung, the heart, the contralateral lung, and the spinal cord were 278.99 ± 51.68 versus 198.75 ± 61.38 (p < 0.05), 216.99 ± 44.13 versus 144.86 ± 43.98 (p < 0.05), 125.96 ± 66.76 versus 111.86 ± 47.19 (p > 0.05), and 194.30 ± 14.51 versus 168.58 ± 25.97 (p < 0.05), respectively. Conclusions: The sharp loss function could significantly improve the accuracy of radiotherapy dose prediction.