EAErdem Aydin

Erdem Aydin

*This is an algorithmically generated author record based on publicly available information.

Erdem Aydin has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of manual pulse, carotid 2D ultrasound, and EtCO2 for detecting ROSC

    by Akin Gullu, Sukru Kockan, Emre Sanci, Erdem Aydin, Ahmet Emir Sari, Asim Enes Ozbek, Huseyin Cahit Halhalli

    Objective: Healthcare providers frequently spend excessive time attempting to identify a pulse and may have difficulty accurately confirming its presence. Point-of-care carotid artery ultrasonography has been suggested as a potential alternative to manual palpation. This study aimed to evaluate the effectiveness of manual palpation, 2D carotid ultrasonography, and rapid increases in end-tidal carbon dioxide (EtCO2) levels for determining the return of spontaneous circulation (ROSC) in patients with cardiac arrest presenting to an emergency department.Methods: This was a single-center, prospective, observational study. Nontraumatic adult patients in cardiopulmonary arrest who were brought to the emergency department were included. After cardiac arrest was identified, the following data were recorded: initial arrest rhythm, ultrasonographic and manual pulse assessments, EtCO2 levels, resuscitation duration, and post-ROSC vital signs. The team leader’s judgment was used for ROSC adjudication and served as the reference standard.Results: The investigation included 88 patients who underwent a total of 642 cycles of cardiopulmonary resuscitation. The area under the curve (AUC) values for 2D carotid ultrasonography, EtCO2, and manual palpation were 0.974, 0.802, and 0.862, respectively (all P<0.001). In pairwise AUC comparisons, ultrasonography differed significantly from manual palpation (P=0.001) and EtCO2 (P<0.001), whereas manual palpation and EtCO2 did not differ significantly (P=0.167). Bedside ultrasonography for detecting a carotid pulse had a sensitivity of 93.8% and a specificity of 100%.Conclusion: These findings suggest that 2D carotid ultrasonography can be effectively used to detect a pulse in patients with cardiopulmonary arrest.

  • Comparison of standard method and triple airway maneuver on LMA insertion times in prehospital cardiac arrest simulation

    by Ahmet Emir Sarı, Asım Enes Özbek, Emre Şancı, Hüseyin Cahit Halhallı, Merve Akın Özdemir, Akin Güllü, Erdem Aydin, Burhan Pehlivan, Hakan Özerol

    In this study, we hypothesized that in prehospital ambulance environments, the use of the triple airway maneuver-which facilitates airway patency in the mannequin-may allow for faster and easier placement of the Laryngeal Mask Airway (LMA). This study aimed to evaluate the effect of the triple airway maneuver on the LMA insertion times of paramedics with and without chest compression. This study was designed as a randomized, prospective, crossover simulated manikin study. Paramedics who were working in the Prehospital Command and Control Center were informed about the study. A randomized, crossover study design was used to reduce the learning curve of the participants. For each participant, four scenarios were created in a randomized order: 1) standard method with chest compressions, 2) triple airway maneuver with chest compressions, 3) standard method without chest compressions, and 4) triple airway maneuver without chest compressions. The study was carried out in a moving ambulance in an empty area. The standard method was defined as passive manual support of the head from below. For the triple airway maneuver, an emergency medicine specialist served as the second operator. The LMA application time was defined as the time until the LMA was held, and effective ventilation was provided. The primary outcome of the study was defined as the comparison of LMA insertion times of the standard method and triple airway maneuver for each method. Twenty-eight participants were included in the study. When all scenarios were compared LMA insertion times did not differ between triple airway maneuver and standard method groups (p = 0.730). During chest compressions, no statistically significant difference was found between the LMA insertion times (mean difference: 0.57 seconds, 95% CI: -0.819 to 1.961; p = 0.406). Similarly, when chest compressions were not applied, no significant difference was observed between the groups (mean difference: 0.5001 seconds, 95% CI: -2.00 to 3.50; p = 0.675). The findings of this study suggest that both the triple airway maneuver and the standard method may be effectively utilized in patients undergoing chest compressions as well as in those without chest compressions.


  • Open Access

    Selective intubation with endotracheal tube introducer in difficult airway

    by Hakan Özerol, Emre Şancı, Onur Karakayalı, Erdem Aydın, Hüseyin Cahit Halhallı

    BACKGROUND: Selective lung intubation is a life-saving procedure in emergency departments. While various equipment can be used in selective lung intubation, most of this equipment is not readily available; therefore, single-lumen endotracheal intubations are performed for rapid interventions. MATERIALS AND METHODS: This study was designed as a randomized, prospective, cross-over study using the 90° rotation technique for selective intubation on a manikin model with and without endotracheal tube introducer (ETI) in difficult airway settings. Forty-six emergency physicians were included in the study. The primary outcome was evaluating time to selective intubations, and secondary outcomes were first and second attempt success rates and the self-perceived difficulty level of each method according to the participants. RESULTS: The mean time to the first successful endotracheal intubation was significantly longer for both right selective and left selective intubations with ETI utilization than without ([39.71 ± 9.83 vs. 21.86 ± 5.94 s], [P < 0.001]), ([42.2 ± 10.81 vs. 26.23 ± 7.97 s], [P < 0.001], respectively). The first-pass success rate did not differ for right selective intubation with or without an ETI (45/46 [97.8%] and 45/46 [97.8%], respectively). However, the first-pass success rate for left selective intubation was significantly higher with ETI as compared to without an ETI (30/46 [65.2%] and 13/46 [28.3%], respectively) (P < 0.001). CONCLUSIONS: While the success rates of right selective intubation were the same, the left selective intubation success rates with ETI are higher than the styletted endotracheal tube, which can be strong evidence for this method's applicability in practice. Expanding the use of ETI and increasing the experience of the practitioners can contribute to further success.