Ahmet Emir Sarı
Ahmet Emir Sarı has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Emre Şancı
Department of Emergency Medicine, Izmir Bakırçay University Çiğli Training and Research Hospital, Izmir, Turkey
3 shared publications - Huseyin Cahit Halhalli
University of Health Sciences, Turkey
3 shared publications - Akin Gullu
Attending Emergency Physician, Sakarya Education and Research Hospital, University of Sakarya, Department of Emergency Medicine, Sakarya, Turkey
2 shared publications - Asim Enes Ozbek
Department of Emergency Medicine, University of Health Sciences Kocaeli Derince Training and Research Hospital, Kocaeli, Turkey
2 shared publications - Erdem Aydin
Attending Emergency Physician, Kocaeli City Hospital, Department of Emergency Medicine, 41900, Kocaeli, Turkey
2 shared publications - Burhan Pehlivan
Department of Emergency Medicine Erbaa State Hospital
1 shared publication
Latest Publications
- Open Access
- 28 January 2026
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 13 (3) , 311-317
Comparison of manual pulse, carotid 2D ultrasound, and EtCO2 for detecting ROSC
Objective: Healthcare providers frequently spend excessive time attempting to identify a pulse and may have difficulty accurately confirming its presence. Point-of-care carotid artery ultrasonography has been suggested as a potential alternative to manual palpation. This study aimed to evaluate the effectiveness of manual palpation, 2D carotid ultrasonography, and rapid increases in end-tidal carbon dioxide (EtCO2) levels for determining the return of spontaneous circulation (ROSC) in patients with cardiac arrest presenting to an emergency department.Methods: This was a single-center, prospective, observational study. Nontraumatic adult patients in cardiopulmonary arrest who were brought to the emergency department were included. After cardiac arrest was identified, the following data were recorded: initial arrest rhythm, ultrasonographic and manual pulse assessments, EtCO2 levels, resuscitation duration, and post-ROSC vital signs. The team leader’s judgment was used for ROSC adjudication and served as the reference standard.Results: The investigation included 88 patients who underwent a total of 642 cycles of cardiopulmonary resuscitation. The area under the curve (AUC) values for 2D carotid ultrasonography, EtCO2, and manual palpation were 0.974, 0.802, and 0.862, respectively (all P<0.001). In pairwise AUC comparisons, ultrasonography differed significantly from manual palpation (P=0.001) and EtCO2 (P<0.001), whereas manual palpation and EtCO2 did not differ significantly (P=0.167). Bedside ultrasonography for detecting a carotid pulse had a sensitivity of 93.8% and a specificity of 100%.Conclusion: These findings suggest that 2D carotid ultrasonography can be effectively used to detect a pulse in patients with cardiopulmonary arrest.
- 28 January 2026
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 13 (3) , 311-317
Open AccessComparison of manual pulse, carotid 2D ultrasound, and EtCO2 for detecting ROSC
Objective: Healthcare providers frequently spend excessive time attempting to identify a pulse and may have difficulty accurately confirming its presence. Point-of-care carotid artery ultrasonography has been suggested as a potential alternative to manual palpation. This study aimed to evaluate the effectiveness of manual palpation, 2D carotid ultrasonography, and rapid increases in end-tidal carbon dioxide (EtCO2) levels for determining the return of spontaneous circulation (ROSC) in patients with cardiac arrest presenting to an emergency department.Methods: This was a single-center, prospective, observational study. Nontraumatic adult patients in cardiopulmonary arrest who were brought to the emergency department were included. After cardiac arrest was identified, the following data were recorded: initial arrest rhythm, ultrasonographic and manual pulse assessments, EtCO2 levels, resuscitation duration, and post-ROSC vital signs. The team leader’s judgment was used for ROSC adjudication and served as the reference standard.Results: The investigation included 88 patients who underwent a total of 642 cycles of cardiopulmonary resuscitation. The area under the curve (AUC) values for 2D carotid ultrasonography, EtCO2, and manual palpation were 0.974, 0.802, and 0.862, respectively (all P<0.001). In pairwise AUC comparisons, ultrasonography differed significantly from manual palpation (P=0.001) and EtCO2 (P<0.001), whereas manual palpation and EtCO2 did not differ significantly (P=0.167). Bedside ultrasonography for detecting a carotid pulse had a sensitivity of 93.8% and a specificity of 100%.Conclusion: These findings suggest that 2D carotid ultrasonography can be effectively used to detect a pulse in patients with cardiopulmonary arrest.
- 23 June 2025
- Published by Taylor & Francis in Prehospital Emergency Care
- p. 1-9
Comparison of standard method and triple airway maneuver on LMA insertion times in prehospital cardiac arrest simulation
In this study, we hypothesized that in prehospital ambulance environments, the use of the triple airway maneuver-which facilitates airway patency in the mannequin-may allow for faster and easier placement of the Laryngeal Mask Airway (LMA). This study aimed to evaluate the effect of the triple airway maneuver on the LMA insertion times of paramedics with and without chest compression. This study was designed as a randomized, prospective, crossover simulated manikin study. Paramedics who were working in the Prehospital Command and Control Center were informed about the study. A randomized, crossover study design was used to reduce the learning curve of the participants. For each participant, four scenarios were created in a randomized order: 1) standard method with chest compressions, 2) triple airway maneuver with chest compressions, 3) standard method without chest compressions, and 4) triple airway maneuver without chest compressions. The study was carried out in a moving ambulance in an empty area. The standard method was defined as passive manual support of the head from below. For the triple airway maneuver, an emergency medicine specialist served as the second operator. The LMA application time was defined as the time until the LMA was held, and effective ventilation was provided. The primary outcome of the study was defined as the comparison of LMA insertion times of the standard method and triple airway maneuver for each method. Twenty-eight participants were included in the study. When all scenarios were compared LMA insertion times did not differ between triple airway maneuver and standard method groups (p = 0.730). During chest compressions, no statistically significant difference was found between the LMA insertion times (mean difference: 0.57 seconds, 95% CI: -0.819 to 1.961; p = 0.406). Similarly, when chest compressions were not applied, no significant difference was observed between the groups (mean difference: 0.5001 seconds, 95% CI: -2.00 to 3.50; p = 0.675). The findings of this study suggest that both the triple airway maneuver and the standard method may be effectively utilized in patients undergoing chest compressions as well as in those without chest compressions.
- 23 June 2025
- Published by Taylor & Francis in Prehospital Emergency Care
- p. 1-9
Comparison of standard method and triple airway maneuver on LMA insertion times in prehospital cardiac arrest simulation
In this study, we hypothesized that in prehospital ambulance environments, the use of the triple airway maneuver-which facilitates airway patency in the mannequin-may allow for faster and easier placement of the Laryngeal Mask Airway (LMA). This study aimed to evaluate the effect of the triple airway maneuver on the LMA insertion times of paramedics with and without chest compression. This study was designed as a randomized, prospective, crossover simulated manikin study. Paramedics who were working in the Prehospital Command and Control Center were informed about the study. A randomized, crossover study design was used to reduce the learning curve of the participants. For each participant, four scenarios were created in a randomized order: 1) standard method with chest compressions, 2) triple airway maneuver with chest compressions, 3) standard method without chest compressions, and 4) triple airway maneuver without chest compressions. The study was carried out in a moving ambulance in an empty area. The standard method was defined as passive manual support of the head from below. For the triple airway maneuver, an emergency medicine specialist served as the second operator. The LMA application time was defined as the time until the LMA was held, and effective ventilation was provided. The primary outcome of the study was defined as the comparison of LMA insertion times of the standard method and triple airway maneuver for each method. Twenty-eight participants were included in the study. When all scenarios were compared LMA insertion times did not differ between triple airway maneuver and standard method groups (p = 0.730). During chest compressions, no statistically significant difference was found between the LMA insertion times (mean difference: 0.57 seconds, 95% CI: -0.819 to 1.961; p = 0.406). Similarly, when chest compressions were not applied, no significant difference was observed between the groups (mean difference: 0.5001 seconds, 95% CI: -2.00 to 3.50; p = 0.675). The findings of this study suggest that both the triple airway maneuver and the standard method may be effectively utilized in patients undergoing chest compressions as well as in those without chest compressions.
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Revista da Associação Médica Brasileira
- Vol. 69 (12) , e20230733
Effect of pulmonary embolism location on electrocardiological parameters
Pulmonary thromboembolism is a disease with high morbidity and mortality. Various changes occur on the electrocardiogram secondary to pulmonary thromboembolism. The objective of this study was to investigate variations in QT dispersion, Tpeak-Tend duration, and Tpeak-Tend/QT ratio in relation to pulmonary thromboembolism localization and their impacts on 30-day mortality.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Revista da Associação Médica Brasileira
- Vol. 69 (12) , e20230733
Open AccessEffect of pulmonary embolism location on electrocardiological parameters
Pulmonary thromboembolism is a disease with high morbidity and mortality. Various changes occur on the electrocardiogram secondary to pulmonary thromboembolism. The objective of this study was to investigate variations in QT dispersion, Tpeak-Tend duration, and Tpeak-Tend/QT ratio in relation to pulmonary thromboembolism localization and their impacts on 30-day mortality.