Yupeng Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yupeng Cao has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Dong Han
CAS Center for Excellence in Nanoscience
1 shared publication Mei Yang
State Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication- Wentao Liu
CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China
1 shared publication - Xiaohan Zhou
CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China
1 shared publication - Xiaoli Liu
School of Future Technology, Xi'an Jiaotong University, Xi'an 710049, China
1 shared publication
Latest Publications
- 4 July 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (28) , 10572-10579
High-Sensitivity, Low-Field 19F-MRI Approach Using High Manganese Ferrite Concentrations
Fluorine-19 (19F) MRI (19F-MRI) is a promising method for quantifying biomedical research and clinical applications without background interference. Nevertheless, dependency on high-field MRI systems limits the applicability of 19F-MRI. Low-field MRI systems are more common than high-field MRI systems. Hence, developing 19F-MRI at low-field MRI devices can promote the 19F-MRI translation in medical diagnosis. The detection sensitivity of fluorine agents is critical in 19F-MRI. Reduction of the 19F spin-lattice relaxation time (T1) enables an improved detection sensitivity while requiring ultrashort echo time (UTE) imaging methods to reduce the negative spin-spin relaxation (T2) decay effect. However, conventional UTE sequences require hardware with high performance. Herein, we introduce the k-space scaling imaging (KSSI) MRI sequence that accomplishes sampling k-space with variable scales to implement hardware-friendly UTE 19F-MRI compatible with low-field MRI systems. We implemented experiments with swine bone, a perfluorooctyl bromide (PFOB) phantom, and one tumor-bearing mouse on two self-customized low-field MRI systems. The swine bone imaging validated the ultrashort TE of KSSI. Under high concentrations of manganese ferrite, a high signal-to-noise ratio was shown in the imaging of a fluorine atom concentration of 658 mM, which indicated high-sensitivity detection of KSSI. Moreover, the KSSI sequence exhibited a 7.1 times signal-to-noise ratio of spin echo sequence on the PFOB phantom imaging with a fluorine atom concentration of 3.29 M. Additionally, the various concentrations of the PFOB phantom imaging revealed quantifiable capacity. Finally, the 1H/19F imaging was implemented with KSSI on one tumor-bearing mouse. This method provides the potential for clinical translation of fluorine probes at low-field MRI systems.
- 4 July 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (28) , 10572-10579
High-Sensitivity, Low-Field 19F-MRI Approach Using High Manganese Ferrite Concentrations
Fluorine-19 (19F) MRI (19F-MRI) is a promising method for quantifying biomedical research and clinical applications without background interference. Nevertheless, dependency on high-field MRI systems limits the applicability of 19F-MRI. Low-field MRI systems are more common than high-field MRI systems. Hence, developing 19F-MRI at low-field MRI devices can promote the 19F-MRI translation in medical diagnosis. The detection sensitivity of fluorine agents is critical in 19F-MRI. Reduction of the 19F spin-lattice relaxation time (T1) enables an improved detection sensitivity while requiring ultrashort echo time (UTE) imaging methods to reduce the negative spin-spin relaxation (T2) decay effect. However, conventional UTE sequences require hardware with high performance. Herein, we introduce the k-space scaling imaging (KSSI) MRI sequence that accomplishes sampling k-space with variable scales to implement hardware-friendly UTE 19F-MRI compatible with low-field MRI systems. We implemented experiments with swine bone, a perfluorooctyl bromide (PFOB) phantom, and one tumor-bearing mouse on two self-customized low-field MRI systems. The swine bone imaging validated the ultrashort TE of KSSI. Under high concentrations of manganese ferrite, a high signal-to-noise ratio was shown in the imaging of a fluorine atom concentration of 658 mM, which indicated high-sensitivity detection of KSSI. Moreover, the KSSI sequence exhibited a 7.1 times signal-to-noise ratio of spin echo sequence on the PFOB phantom imaging with a fluorine atom concentration of 3.29 M. Additionally, the various concentrations of the PFOB phantom imaging revealed quantifiable capacity. Finally, the 1H/19F imaging was implemented with KSSI on one tumor-bearing mouse. This method provides the potential for clinical translation of fluorine probes at low-field MRI systems.