Carlotta Hennigs
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carlotta Hennigs has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Philipp Rostalski
Fraunhofer Research Institution for Individualized Medical Technology and Engineering, IMTE, Luebeck, Germany
3 shared publications - Franziska Schollemann
Department of Anesthesiology, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52074 Aachen, Germany
2 shared publications - Alexander Bigalke
Institute of Medical Informatics, University of Lübeck, Lübeck, Germany
1 shared publication - Dirk Schädler
University Hospital Schleswig-Holstein
1 shared publication - Georg Männel
Fraunhofer Research Institution for Individualized Medical Technology and Engineering IMTE, Mönkhofer Weg 239a Lübeck, Germany
1 shared publication - Helene Selpien
Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3 Kiel, Germany
1 shared publication
Latest Publications
- Open Access
- 19 March 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 280, 109329
Patient-ventilator interaction—Development of a mathematical model of the respiratory center
- 19 March 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 280, 109329
Open AccessPatient-ventilator interaction—Development of a mathematical model of the respiratory center
- 1 May 2024
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 72 (5) , 417-428
A switching lung mechanics model for detection of expiratory flow limitation
Expiratory flow limitation (EFL) is an often unrecognized clinical condition with a multitude of negative implications. A mathematical EFL model is proposed to detect flow limitations automatically. The EFL model is a switching one-compartment lung mechanics model with a volume-dependent airway resistance to simulate the dynamic behavior during expiration. The EFL detection is based on a breath-by-breath model parameter identification and validated on clinical data of mechanically ventilated patients. In the severe flow limitation group 93.9 % ± 5 % and in the no limitation group 10.2 % ± 13.7 % of the breaths are detected as EFL. Based on the high detection rate of EFL, these results support the usefulness of the EFL detection. It is a first step toward an automated detection of EFL in clinical applications and may help to reduce underdiagnosis of EFL.
- 1 May 2024
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 72 (5) , 417-428
A switching lung mechanics model for detection of expiratory flow limitation
Expiratory flow limitation (EFL) is an often unrecognized clinical condition with a multitude of negative implications. A mathematical EFL model is proposed to detect flow limitations automatically. The EFL model is a switching one-compartment lung mechanics model with a volume-dependent airway resistance to simulate the dynamic behavior during expiration. The EFL detection is based on a breath-by-breath model parameter identification and validated on clinical data of mechanically ventilated patients. In the severe flow limitation group 93.9 % ± 5 % and in the no limitation group 10.2 % ± 13.7 % of the breaths are detected as EFL. Based on the high detection rate of EFL, these results support the usefulness of the EFL detection. It is a first step toward an automated detection of EFL in clinical applications and may help to reduce underdiagnosis of EFL.
- 7 July 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 89, 102887
Anatomy-guided domain adaptation for 3D in-bed human pose estimation
- 7 July 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 89, 102887
Anatomy-guided domain adaptation for 3D in-bed human pose estimation
- Open Access
- 1 August 2022
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 8 (2) , 376-379
Mathematical lung model for local gas exchange based on EIT-measurements
In this work we present a four compartment mathematical lung model to simulate the local gas exchange based on electrical impedance tomography (EIT) input. The model simulates the local and global time course of the volume, the gas fraction in the alveoli and the arterial partial pressure. The regional information about the distribution of ventilation and perfusion is extracted from EIT data. In order to illustrate the suitability of this approach, an ARDS patient is simulated. The results show good agreement with measurement data for large portions of the time and seem promising e.g. for the use in medical decision support systems.
- 1 August 2022
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 8 (2) , 376-379
Open AccessMathematical lung model for local gas exchange based on EIT-measurements
In this work we present a four compartment mathematical lung model to simulate the local gas exchange based on electrical impedance tomography (EIT) input. The model simulates the local and global time course of the volume, the gas fraction in the alveoli and the arterial partial pressure. The regional information about the distribution of ventilation and perfusion is extracted from EIT data. In order to illustrate the suitability of this approach, an ARDS patient is simulated. The results show good agreement with measurement data for large portions of the time and seem promising e.g. for the use in medical decision support systems.