JQJimmy Qiu

Jimmy Qiu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jimmy Qiu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A mixed reality hand fracture simulator for virtual K-wire fixation

    by Jimmy Qiu, Trinette Wright, Stephanie Williams, Daniel Lin, Clare McElcheran, Stefan Hofer, Blake Murphy, Joseph Catapano

    Purpose Proper management of hand fractures requires accurate reduction of bone fragments and stabilization with Kirschner wire (K-wire) fixation. Limited case exposure in residency and a shortage of feedback-rich skills assessment constrain deliberate practice. This work describes a mixed reality hand fracture simulator that integrates a realistic physical model with instrument tracking, real-time virtual image guidance, and quantitative performance feedback for training percutaneous K-wire fixation. Methods We developed a benchtop mixed reality (MR) simulator integrating an electromagnetic (EM) tracker, a three-dimensional (3D)-printed hand model with fracture patterns, and a microcontroller-enabled K-wire driver. To ensure high physical-to-virtual geometric correspondence, the 3D-printed components were optically scanned to serve as virtual representations. A custom application provides real-time 3D visualization, guidance, and simulated virtual X-rays. To evaluate system accuracy, five users performed repeated paired-point rigid registrations. Accuracy was assessed by calculating fiducial registration error (FRE) and target registration error (TRE) across 25 attempts using a pre-calibrated stylus and the tracked K-wire driver. Image guidance capabilities were evaluated by measuring positional and angular alignment errors of the tracked K-wire driver against predefined ideal trajectories. Results The overall mean FRE was 0.69 ± 0.11 mm for the hand model (11 fiducials) and 0.60 ± 0.09 mm for the K-wire driver (8 fiducials). Target localization to six ground-truth targets yielded a mean TRE of 0.69 ± 0.10 mm with the stylus and 0.82 ± 0.16 mm with the driver. Trajectory alignment demonstrated maximum positional variance during parallel approaches to the bone (K-wire 1), highlighting specific procedural challenges. Conclusions The MR hand fracture simulator platform enables repeated practice of fracture reduction and K-wire placement with interactive guidance, simulated X-rays, and objective metrics. The system is able to achieve millimeter-scale alignment suitable for procedural training. Future work will evaluate learning outcomes and skill transfer in surgical trainees.

  • Open Access

    Optimizing AI implementation for surgery: recommendations for infrastructure and deployment in the operating room

    by Ariana Walji, Caterina Masino, Stephanie Williams, Spencer Gable-Cook, Jimmy Qiu, Pouria Mashouri, Divya Kewalramani, Mayur Narayan, Tyler J. Loftus, Wagner H. Souza, et al.

    Recent years have seen a surge in the development of Artificial Intelligence (AI) technologies to enhance intraoperative decision-making and improve patient safety. Yet, real-world evidence on their implementation remains limited. This study evaluated the impact of AI deployment in the operating room across key implementation domains-usability, cost, and carbon footprint-using cloud and edge-based infrastructures. Twenty-three end-users (surgeons, residents, fellows, operating room nurses) from a multi-site teaching hospital in Canada participated in system usability testing, assessed with validated scales and open-ended feedback. Cost and carbon footprint were assessed based on operational metrics. Results showed greater deployment task completion with Cloud but increased physical strain, carbon emissions, and operational costs compared to Edge after 396 h of use. Despite similar usability ratings, participants suggested improvements to the Cloud setup and both systems' interface. Findings provide evidence-based recommendations toward the implementation of sustainable, user-centered AI systems in surgical practice.


  • Open Access

    Automatic Registration and Error Color Maps to Improve Accuracy for Navigated Bone Tumor Surgery Using Intraoperative Cone-Beam CT

    by Axel Sahovaler, Michael J. Daly, Harley H.L. Chan, Prakash Nayak, Sharon Tzelnick, Michelle Arkhangorodsky, Jimmy Qiu, Robert Weersink, Jonathan C. Irish, Peter Ferguson, et al.

    Background: Computer-assisted surgery (CAS) can improve surgical precision in orthopaedic oncology. Accurate alignment of the patient’s imaging coordinates with the anatomy, known as registration, is one of the most challenging aspects of CAS and can be associated with substantial error. Using intraoperative, on-the-table, cone-beam computed tomography (CBCT), we performed a pilot clinical study to validate a method for automatic intraoperative registration. Methods: Patients who were ≥18 years of age, had benign bone tumors, and underwent resection were prospectively enrolled. In addition to inserting a navigation tracking tool into the exposed bone adjacent to the surgical field, 2 custom plastic ULTEM tracking tools (UTTs) were attached to each patient’s skin adjacent to the tumor using an adhesive. These were automatically localized within the 3-dimensional CBCT volume to be used as image landmarks for registration, and the corresponding tracker landmarks were captured using an infrared camera. The main outcomes were the fiducial registration error (FRE) and the target registration error (TRE). The navigation time was recorded. Results: Thirteen patients with benign tumors in the femur (n = 10), tibia (n = 2), and humerus (n = 1) underwent navigation-assisted resections. The mean values were 0.67 ± 0.15 mm (range, 0.47 to 0.97 mm) for FRE and 0.83 ± 0.51 mm (range, 0.42 to 2.28 mm) for TRE. Registration was successful in all cases. The mean time for CBCT imaging and tracker registration was 7.5 minutes. Conclusions: We present a novel automatic registration method for CAS exploiting intraoperative CBCT capabilities, which provided improved accuracy and reduced operative times compared with more traditional methods. Clinical Relevance: This proof-of-principle study validated a novel process for automatic registration to improve the accuracy of resecting bone tumors using a surgical navigation system.