Blake D. Murphy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Blake D. Murphy has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Clare McElcheran
Techna, University Health Network, Toronto, Canada
1 shared publication - Daniel Lin
Techna, University Health Network, Toronto, Canada
1 shared publication - Jimmy Qiu
Techna, University Health Network, Toronto, Canada
1 shared publication Joseph Catapano
Univ Toronto, Dept Surg, Div Plast & Reconstruct Surg, Toronto, ON, Canada
1 shared publication- Joseph Catapano
Division of Plastic, Reconstructive and Aesthetic Surgery, University of Toronto, Toronto, Canada
1 shared publication Mark S. Sha Fa Renko
Univ Toronto, Dept Surg, Div Plast & Reconstruct Surg, Toronto, ON, Canada
1 shared publication
Latest Publications
- 20 August 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- p. 1-14
A mixed reality hand fracture simulator for virtual K-wire fixation
Purpose Proper management of hand fractures requires accurate reduction of bone fragments and stabilization with Kirschner wire (K-wire) fixation. Limited case exposure in residency and a shortage of feedback-rich skills assessment constrain deliberate practice. This work describes a mixed reality hand fracture simulator that integrates a realistic physical model with instrument tracking, real-time virtual image guidance, and quantitative performance feedback for training percutaneous K-wire fixation. Methods We developed a benchtop mixed reality (MR) simulator integrating an electromagnetic (EM) tracker, a three-dimensional (3D)-printed hand model with fracture patterns, and a microcontroller-enabled K-wire driver. To ensure high physical-to-virtual geometric correspondence, the 3D-printed components were optically scanned to serve as virtual representations. A custom application provides real-time 3D visualization, guidance, and simulated virtual X-rays. To evaluate system accuracy, five users performed repeated paired-point rigid registrations. Accuracy was assessed by calculating fiducial registration error (FRE) and target registration error (TRE) across 25 attempts using a pre-calibrated stylus and the tracked K-wire driver. Image guidance capabilities were evaluated by measuring positional and angular alignment errors of the tracked K-wire driver against predefined ideal trajectories. Results The overall mean FRE was 0.69 ± 0.11 mm for the hand model (11 fiducials) and 0.60 ± 0.09 mm for the K-wire driver (8 fiducials). Target localization to six ground-truth targets yielded a mean TRE of 0.69 ± 0.10 mm with the stylus and 0.82 ± 0.16 mm with the driver. Trajectory alignment demonstrated maximum positional variance during parallel approaches to the bone (K-wire 1), highlighting specific procedural challenges. Conclusions The MR hand fracture simulator platform enables repeated practice of fracture reduction and K-wire placement with interactive guidance, simulated X-rays, and objective metrics. The system is able to achieve millimeter-scale alignment suitable for procedural training. Future work will evaluate learning outcomes and skill transfer in surgical trainees.
- 20 August 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- p. 1-14
A mixed reality hand fracture simulator for virtual K-wire fixation
Purpose Proper management of hand fractures requires accurate reduction of bone fragments and stabilization with Kirschner wire (K-wire) fixation. Limited case exposure in residency and a shortage of feedback-rich skills assessment constrain deliberate practice. This work describes a mixed reality hand fracture simulator that integrates a realistic physical model with instrument tracking, real-time virtual image guidance, and quantitative performance feedback for training percutaneous K-wire fixation. Methods We developed a benchtop mixed reality (MR) simulator integrating an electromagnetic (EM) tracker, a three-dimensional (3D)-printed hand model with fracture patterns, and a microcontroller-enabled K-wire driver. To ensure high physical-to-virtual geometric correspondence, the 3D-printed components were optically scanned to serve as virtual representations. A custom application provides real-time 3D visualization, guidance, and simulated virtual X-rays. To evaluate system accuracy, five users performed repeated paired-point rigid registrations. Accuracy was assessed by calculating fiducial registration error (FRE) and target registration error (TRE) across 25 attempts using a pre-calibrated stylus and the tracked K-wire driver. Image guidance capabilities were evaluated by measuring positional and angular alignment errors of the tracked K-wire driver against predefined ideal trajectories. Results The overall mean FRE was 0.69 ± 0.11 mm for the hand model (11 fiducials) and 0.60 ± 0.09 mm for the K-wire driver (8 fiducials). Target localization to six ground-truth targets yielded a mean TRE of 0.69 ± 0.10 mm with the stylus and 0.82 ± 0.16 mm with the driver. Trajectory alignment demonstrated maximum positional variance during parallel approaches to the bone (K-wire 1), highlighting specific procedural challenges. Conclusions The MR hand fracture simulator platform enables repeated practice of fracture reduction and K-wire placement with interactive guidance, simulated X-rays, and objective metrics. The system is able to achieve millimeter-scale alignment suitable for procedural training. Future work will evaluate learning outcomes and skill transfer in surgical trainees.
- Open Access
- 2 November 2022
- Published by Taylor & Francis
- Vol. 10 (11) , e4656
The Role of Augmented Reality in the Next Phase of Surgical Education
Concomitant with such a shift toward competency-based curricula, there has been increasing adoption of surgical simulation coupled with virtual, mixed, and augmented reality. These technologies have become more commonplace across multiple surgical disciplines, in domains such as preoperative planning, surgical education, and intraoperative navigation. However, there is a relative paucity of literature pertaining to the application of this technology to plastic surgery education. This review outlines the advantages of mixed and augmented reality in the pursuit of an ideal simulation environment, their benefits for the education of plastic surgery trainees, and their role in standardized assessments. In addition, we offer practical solutions to commonly encountered problems with this technology. Augmented reality has tremendous untapped potential in the next phase of plastic surgery education, and we outline steps toward broader implementation to enhance the learning environment for our trainees and to improve patient outcomes.
- 2 November 2022
- Published by Taylor & Francis
- Vol. 10 (11) , e4656
Open AccessThe Role of Augmented Reality in the Next Phase of Surgical Education
Concomitant with such a shift toward competency-based curricula, there has been increasing adoption of surgical simulation coupled with virtual, mixed, and augmented reality. These technologies have become more commonplace across multiple surgical disciplines, in domains such as preoperative planning, surgical education, and intraoperative navigation. However, there is a relative paucity of literature pertaining to the application of this technology to plastic surgery education. This review outlines the advantages of mixed and augmented reality in the pursuit of an ideal simulation environment, their benefits for the education of plastic surgery trainees, and their role in standardized assessments. In addition, we offer practical solutions to commonly encountered problems with this technology. Augmented reality has tremendous untapped potential in the next phase of plastic surgery education, and we outline steps toward broader implementation to enhance the learning environment for our trainees and to improve patient outcomes.