Peiji Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peiji Chen has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Yinlai Jiang
Department of Mechanical and Intelligent Systems Engineering, The University of Electro-Communications, Tokyo, Japan
5 shared publications - Hiroshi Yokoi
The University of Electro-Communications
3 shared publications Hiroshi Yokoi
Department of Mechanical Engineering and Intelligent System, the University of Electro-Communications, Tokyo, Japan; Center for Neuroscience and Biomedical Engineering, the University of Electro-Communications, Tokyo, Japan
2 shared publications- Shunta Togo
Department of Mechanical and Intelligent Systems Engineering, The University of Electro-Communications, Tokyo, Japan
2 shared publications - Dian Li
Department of Mechanical and Intelligent Systems Engineering, The University of Electro-Communications, Tokyo 182-8585, Japan
1 shared publication Haokang Xu
The University of Electro-Communications
1 shared publication
Latest Publications
- Open Access
SRM: A Source-Reprojection Module for Cross-Day sEMG Gesture Recognition
Surface electromyography (sEMG) gesture recognition degrades across recording days under domain shift, increasing calibration burden for myoelectric interfaces. Many cross-day adaptation pipelines retrain the deployed recognizer or require labeled target-session data, which can be impractical in assistive-device settings where classifier versions may need to remain locked for traceability and regulatory compliance. We study unsupervised cross-day adaptation under two constraints: the task classifier remains frozen and holdout-day labels are not used when training the adaptor. We propose the Source-Reprojection Module (SRM), a plug-in front end that combines conditional adversarial feature learning with a residual signal-space projector guided by the frozen classifier’s gradients, identity regularization, and latent-space distribution matching, using labeled source days and unlabeled adaptation days only. On a multi-day protocol with four healthy participants (at least five calendar-day sessions per participant, split 3:1:1 into source, adaptation, and holdout domains) and three random seeds per participant (12 runs), mean holdout accuracy increases from 70.9% for the frozen classifier alone to 72.8% with SRM ( percentage points averaged across subjects). SRM outperforms the frozen baseline in 10 of 12 subject–seed runs. The gain is modest and the cohort is small, so the result supports proof-of-mechanism under the stated protocol rather than population-level clinical generalization.Open AccessSRM: A Source-Reprojection Module for Cross-Day sEMG Gesture Recognition
Surface electromyography (sEMG) gesture recognition degrades across recording days under domain shift, increasing calibration burden for myoelectric interfaces. Many cross-day adaptation pipelines retrain the deployed recognizer or require labeled target-session data, which can be impractical in assistive-device settings where classifier versions may need to remain locked for traceability and regulatory compliance. We study unsupervised cross-day adaptation under two constraints: the task classifier remains frozen and holdout-day labels are not used when training the adaptor. We propose the Source-Reprojection Module (SRM), a plug-in front end that combines conditional adversarial feature learning with a residual signal-space projector guided by the frozen classifier’s gradients, identity regularization, and latent-space distribution matching, using labeled source days and unlabeled adaptation days only. On a multi-day protocol with four healthy participants (at least five calendar-day sessions per participant, split 3:1:1 into source, adaptation, and holdout domains) and three random seeds per participant (12 runs), mean holdout accuracy increases from 70.9% for the frozen classifier alone to 72.8% with SRM ( percentage points averaged across subjects). SRM outperforms the frozen baseline in 10 of 12 subject–seed runs. The gain is modest and the cohort is small, so the result supports proof-of-mechanism under the stated protocol rather than population-level clinical generalization. - Open Access
- 14 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (1) , 338-345
A Coupled Tendon-Driven Modular Robotic Hand for Dexterous Manipulation
This letter presents a modular coupled tendon-driven robotichand that employs a 2 motor 2 degrees-of-freedom (2M2D) coupled tendon driven joint module, in which two motors operate in a coordinated manner to actively drive flexion/extension and abduction/adduction of each finger through four tendons fixed to the fingertip. This coupled mechanism significantly enhances output torque while maintaining a simplified layout, each finger and corresponding actuator is implemented as an independent, detachable module, enhancing system flexibility and maintainability. Experimental results demonstrated that the coupled tendon-driven mechanism enhanced fingertip, lateral swing forces and load-bearing capacity by approximately 70$\%$ compared to decoupled tendon-driven mechanism. In terms of dexterity, the proposed hand achieved the highest score in the Kapandji test, fully reaching all ten reference positions, successfully completed all 33 grasp types defined in the GRASP taxonomy, and demonstrated effective in-hand manipulation capabilities. These results highlight the system’s strong potential for applications in dexterous robotic hands, prosthetic devices, and service robots.
- 14 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (1) , 338-345
Open AccessA Coupled Tendon-Driven Modular Robotic Hand for Dexterous Manipulation
This letter presents a modular coupled tendon-driven robotichand that employs a 2 motor 2 degrees-of-freedom (2M2D) coupled tendon driven joint module, in which two motors operate in a coordinated manner to actively drive flexion/extension and abduction/adduction of each finger through four tendons fixed to the fingertip. This coupled mechanism significantly enhances output torque while maintaining a simplified layout, each finger and corresponding actuator is implemented as an independent, detachable module, enhancing system flexibility and maintainability. Experimental results demonstrated that the coupled tendon-driven mechanism enhanced fingertip, lateral swing forces and load-bearing capacity by approximately 70$\%$ compared to decoupled tendon-driven mechanism. In terms of dexterity, the proposed hand achieved the highest score in the Kapandji test, fully reaching all ten reference positions, successfully completed all 33 grasp types defined in the GRASP taxonomy, and demonstrated effective in-hand manipulation capabilities. These results highlight the system’s strong potential for applications in dexterous robotic hands, prosthetic devices, and service robots.
- Open Access
- 2 December 2024
- Published by Elsevier in Neural Networks
- Vol. 183, 106960
Intra- and inter-channel deep convolutional neural network with dynamic label smoothing for multichannel biosignal analysis
- 2 December 2024
- Published by Elsevier in Neural Networks
- Vol. 183, 106960
Open AccessIntra- and inter-channel deep convolutional neural network with dynamic label smoothing for multichannel biosignal analysis
- 10 October 2023
- Published by Springer Nature
- p. 185-194
A Strain Gauge Based FMG Sensor for sEMG-FMG Dual Modal Measurement of Muscle Activity Associated with Hand Gestures
- 10 October 2023
- Published by Springer Nature
- p. 185-194
A Strain Gauge Based FMG Sensor for sEMG-FMG Dual Modal Measurement of Muscle Activity Associated with Hand Gestures
- Open Access
- 10 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 53 (5) , 935-944
A Layered sEMG–FMG Hybrid Sensor for Hand Motion Recognition From Forearm Muscle Activities
The activities of muscles in the forearm have been widely investigated to develop human interfaces involving hand motions, especially in the fields of prosthetic hands and teleoperation. Although surface electromyography (sEMG) is considered as an effective biological signal from which hand motions can be recognized, the availability and quality of sEMG data can limit the usability and intuitiveness of human interfaces. This article introduces force myography (FMG) as a supplementary signal and proposes a layered sEMG–FMG hybrid sensor that can measure both sEMG and FMG at the same skin surface location. Meanwhile, a layer fusion convolution neural network (LFC) is designed to extract multiscale features from sEMG and FMG. To evaluate the effectiveness of the hybrid sEMG–FMG sensor and LFC, a 22-hand motion classification experiment was conducted on nine able-bodied subjects. The recognition results indicated a significantly improved classification accuracy (p < 0.001) of the hybrid sEMG–FMG modality with respect to single sEMG or FMG modality. The classification accuracies (CAs) of LFC were compared with conventional machine learning methods, including support vector machine, random forest classifier, xgboost, and k-nearest neighbor. Compared with the single-modality sEMG, the CAs of the dual-modality sEMG–FMG using conventional methods, and LFC were improved by 21.31% and 16.71%, respectively. These results suggest that the layered sEMG–FMG sensing approach can effectively enhance the performance of human interfaces, which offers great potential in the clinical applications of sophisticated prosthetic hands and teleoperation.
- 10 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 53 (5) , 935-944
Open AccessA Layered sEMG–FMG Hybrid Sensor for Hand Motion Recognition From Forearm Muscle Activities
The activities of muscles in the forearm have been widely investigated to develop human interfaces involving hand motions, especially in the fields of prosthetic hands and teleoperation. Although surface electromyography (sEMG) is considered as an effective biological signal from which hand motions can be recognized, the availability and quality of sEMG data can limit the usability and intuitiveness of human interfaces. This article introduces force myography (FMG) as a supplementary signal and proposes a layered sEMG–FMG hybrid sensor that can measure both sEMG and FMG at the same skin surface location. Meanwhile, a layer fusion convolution neural network (LFC) is designed to extract multiscale features from sEMG and FMG. To evaluate the effectiveness of the hybrid sEMG–FMG sensor and LFC, a 22-hand motion classification experiment was conducted on nine able-bodied subjects. The recognition results indicated a significantly improved classification accuracy (p < 0.001) of the hybrid sEMG–FMG modality with respect to single sEMG or FMG modality. The classification accuracies (CAs) of LFC were compared with conventional machine learning methods, including support vector machine, random forest classifier, xgboost, and k-nearest neighbor. Compared with the single-modality sEMG, the CAs of the dual-modality sEMG–FMG using conventional methods, and LFC were improved by 21.31% and 16.71%, respectively. These results suggest that the layered sEMG–FMG sensing approach can effectively enhance the performance of human interfaces, which offers great potential in the clinical applications of sophisticated prosthetic hands and teleoperation.