Jaena Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jaena Park has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Stephen A. Boppart
University of Illinois Urbana-Champaign
3 shared publications - Darold R. Spillman
Univ. of Illinois (United States)
2 shared publications - Eric J. Chaney
Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
2 shared publications - Heidi Phillips
Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana, IL 61802, USA
2 shared publications - Lingxiao Yang
Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois 61801, USA
2 shared publications - Alejandro De la Cadena
Beckman Institute for Advanced Science & Technology, University of Illinois Urbana-Champaign, Urbana, IL, USA
1 shared publication
Latest Publications
- Open Access
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-10
Label-free correlative morpho-chemical tomography of 3D kidney mesangial cells
SignificanceImaging 3D in vitro kidney models is essential to understand kidney function and pathology. Label-free characterization of such specimens seeks to supplement existing imaging techniques and avoid the need for contrast agents that can disturb the native state of living samples. Conventional label-free optical imaging techniques are compatible with living samples but face challenges such as poor sectioning capability, fragmentary morphology, and lack of chemical-specific information.AimWe aim to develop and demonstrate a correlative label-free imaging platform capable of simultaneously capturing morphological and chemical-specific information from 3D cultured kidney mesangial cells.ApproachWe combined simultaneous label-free autofluorescence-multiharmonic (SLAM) microscopy and gradient light interference microscopy (GLIM) to extract both chemical-specific and morphological tomography of 3D cultured kidney mesangial cells. In this approach, SLAM provides a nonlinear imaging platform with a single excitation source to simultaneously acquire autofluorescence (FAD and NAD(P)H), second- and third-harmonic signals from the cells. Complementarily, GLIM acquires high-contrast quantitative phase information to quantify structural changes in samples with a thickness of up to 250 μm.ResultsOur correlative imaging results demonstrate the ability to image and quantify both morphology and chemical-specific signals of kidney mesangial cells in 3D. The combination of GLIM and SLAM provides complementary information critical for understanding kidney function, including metabolism and matrix deposition under controlled physiological conditions.ConclusionsThe proposed correlative imaging approach establishes a versatile and hassle-free platform for morpho-chemical cellular tomography, offering unique opportunities for studying the structure and function of 3D kidney models in their native state.
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-10
Open AccessLabel-free correlative morpho-chemical tomography of 3D kidney mesangial cells
SignificanceImaging 3D in vitro kidney models is essential to understand kidney function and pathology. Label-free characterization of such specimens seeks to supplement existing imaging techniques and avoid the need for contrast agents that can disturb the native state of living samples. Conventional label-free optical imaging techniques are compatible with living samples but face challenges such as poor sectioning capability, fragmentary morphology, and lack of chemical-specific information.AimWe aim to develop and demonstrate a correlative label-free imaging platform capable of simultaneously capturing morphological and chemical-specific information from 3D cultured kidney mesangial cells.ApproachWe combined simultaneous label-free autofluorescence-multiharmonic (SLAM) microscopy and gradient light interference microscopy (GLIM) to extract both chemical-specific and morphological tomography of 3D cultured kidney mesangial cells. In this approach, SLAM provides a nonlinear imaging platform with a single excitation source to simultaneously acquire autofluorescence (FAD and NAD(P)H), second- and third-harmonic signals from the cells. Complementarily, GLIM acquires high-contrast quantitative phase information to quantify structural changes in samples with a thickness of up to 250 μm.ResultsOur correlative imaging results demonstrate the ability to image and quantify both morphology and chemical-specific signals of kidney mesangial cells in 3D. The combination of GLIM and SLAM provides complementary information critical for understanding kidney function, including metabolism and matrix deposition under controlled physiological conditions.ConclusionsThe proposed correlative imaging approach establishes a versatile and hassle-free platform for morpho-chemical cellular tomography, offering unique opportunities for studying the structure and function of 3D kidney models in their native state.
- Open Access
- 28 May 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (05) , 056504-18
Label-free multimodal nonlinear optical imaging of needle biopsy cores for intraoperative cancer diagnosis
Cancer is the second leading cause of death in the United States1 and developing new technologies and methods for cancer diagnosis has been a major research field in biomedicine. For the diagnosis of cancer, especially in liver, lung, breast, prostate, and soft tissue tumors,2 it is a standard clinical practice to acquire and evaluate needle biopsy (NB) specimens before deciding on the treatment plan, such as the need for chemotherapy, radiation therapy, and/or surgical procedures.2 NB procedures include fine-needle aspiration, which often uses syringes to collect fluids for cytological evaluation, and core-needle biopsy, which collects tissue cores from suspicious regions.2 – 5 This study will focus on the collection and evaluation of NB core specimens, but the technologies and methods presented here could similarly be used to assess the cytologic content from fine-needle aspirations. NB core specimens are commonly fixed right after the acquisition and go through standard histological procedures including sectioning and staining.2 Although histopathology is the gold standard for cancer diagnosis, this conventional evaluation method often takes a day or more to generate the results.6,7 The time-consuming histological evaluation has become more of a concerning factor when the NB sampling is inadequate or non-diagnostic, which means the histology results of NB specimens fail to provide any diagnostic information, such as the presence of cancer cells. In this case, additional specimens are required, which further delays the diagnostic decisions.2,8 Therefore, there is a critical need to have a rapid screening and evaluation method of NB cores right after extraction and at the point-of-procedure.
- 28 May 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (05) , 056504-18
Open AccessLabel-free multimodal nonlinear optical imaging of needle biopsy cores for intraoperative cancer diagnosis
Cancer is the second leading cause of death in the United States1 and developing new technologies and methods for cancer diagnosis has been a major research field in biomedicine. For the diagnosis of cancer, especially in liver, lung, breast, prostate, and soft tissue tumors,2 it is a standard clinical practice to acquire and evaluate needle biopsy (NB) specimens before deciding on the treatment plan, such as the need for chemotherapy, radiation therapy, and/or surgical procedures.2 NB procedures include fine-needle aspiration, which often uses syringes to collect fluids for cytological evaluation, and core-needle biopsy, which collects tissue cores from suspicious regions.2 – 5 This study will focus on the collection and evaluation of NB core specimens, but the technologies and methods presented here could similarly be used to assess the cytologic content from fine-needle aspirations. NB core specimens are commonly fixed right after the acquisition and go through standard histological procedures including sectioning and staining.2 Although histopathology is the gold standard for cancer diagnosis, this conventional evaluation method often takes a day or more to generate the results.6,7 The time-consuming histological evaluation has become more of a concerning factor when the NB sampling is inadequate or non-diagnostic, which means the histology results of NB specimens fail to provide any diagnostic information, such as the presence of cancer cells. In this case, additional specimens are required, which further delays the diagnostic decisions.2,8 Therefore, there is a critical need to have a rapid screening and evaluation method of NB cores right after extraction and at the point-of-procedure.
- Open Access
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 27 (4) , 1-12
Intraoperative Label-Free Multimodal Nonlinear Optical Imaging for Point-of-Procedure Cancer Diagnostics
Intraoperative imaging in surgical oncology can provide information about the tumor microenvironment as well as information about the tumor margin. Visualizing microstructural features and molecular and functional dynamics may provide important diagnostic and prognostic information, especially when obtained in real-time at the point-of-procedure. A majority of current intraoperative optical techniques are based on the use of the labels, such as fluorescent dyes. However, these exogenous agents disrupt the natural microenvironment, perturb biological processes, and alter the endogenous optical signatures that cells and the microenvironment can provide. Portable nonlinear imaging systems have enabled intraoperative imaging for real-time detection and diagnosis of tissue. We review the development of a label-free multimodal nonlinear optical imaging technique that was adapted into a portable imaging system for intraoperative optical assessment of resected human breast tissue. New developments have applied this technology to assessing needle-biopsy specimens. Needle-biopsy procedures most always precede surgical resection and serve as the first sampling of suspicious masses for diagnosis. We demonstrate the diagnostic feasibility of imaging core needle-biopsy specimens during veterinary cancer surgeries. This intraoperative label-free multimodal nonlinear optical imaging technique can potentially provide a powerful tool to assist in cancer diagnosis at the point-of-procedure.
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 27 (4) , 1-12
Open AccessIntraoperative Label-Free Multimodal Nonlinear Optical Imaging for Point-of-Procedure Cancer Diagnostics
Intraoperative imaging in surgical oncology can provide information about the tumor microenvironment as well as information about the tumor margin. Visualizing microstructural features and molecular and functional dynamics may provide important diagnostic and prognostic information, especially when obtained in real-time at the point-of-procedure. A majority of current intraoperative optical techniques are based on the use of the labels, such as fluorescent dyes. However, these exogenous agents disrupt the natural microenvironment, perturb biological processes, and alter the endogenous optical signatures that cells and the microenvironment can provide. Portable nonlinear imaging systems have enabled intraoperative imaging for real-time detection and diagnosis of tissue. We review the development of a label-free multimodal nonlinear optical imaging technique that was adapted into a portable imaging system for intraoperative optical assessment of resected human breast tissue. New developments have applied this technology to assessing needle-biopsy specimens. Needle-biopsy procedures most always precede surgical resection and serve as the first sampling of suspicious masses for diagnosis. We demonstrate the diagnostic feasibility of imaging core needle-biopsy specimens during veterinary cancer surgeries. This intraoperative label-free multimodal nonlinear optical imaging technique can potentially provide a powerful tool to assist in cancer diagnosis at the point-of-procedure.