E. C. dos Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
E. C. dos Santos has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Cursino Brandao Jacobina
Electrical Engineering, Federal University of Campina Grande, Campina Grande, Brazil
3 shared publications - Edison R. C. Da Silva
Departamento de Engenharia Elétrica, Universidade Federal de Campina Grande, Caixa Postal 10.105, 58109-970 Campina Grande - PB - Brazil
2 shared publications - Mauricio Beltrao de Rossiter Correa
Electrical Engineering Department, Universidade Federal de Alagoas, Macei, Brazil
2 shared publications - Aluisio A. M. Bento
Departamento de Engenharia Elétrica, Universidade Federal de Campina Grande, Caixa Postal 10.105, 58109-970 Campina Grande - PB - Brazil
1 shared publication - I. S. de Freitas
Departamento de Engenharia Elétrica, Universidade Federal de Campina Grande, Caixa Postal 10.105, 58109-970 Campina Grande - PB - Brazil
1 shared publication
Latest Publications
- 1 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10482334,p. 1958-1963
Two-Machine Drive Systems Using a Photovoltaic Energy Source and a Standard Three-Leg Inverter
This paper proposes three topologies of drive systems to supply independently two induction machines. A commercial three-leg inverter connected to a photovoltaic energy source have been used to supply both motors. The proposed two-motor drive systems are seen as a potentially viable solution for remote applications requiring one high-power (three-phase machine) and one low-power machine (single-phase machine). All the proposed solutions have less power devices than the typical solution.
- 1 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10482334,p. 1958-1963
Two-Machine Drive Systems Using a Photovoltaic Energy Source and a Standard Three-Leg Inverter
This paper proposes three topologies of drive systems to supply independently two induction machines. A commercial three-leg inverter connected to a photovoltaic energy source have been used to supply both motors. The proposed two-motor drive systems are seen as a potentially viable solution for remote applications requiring one high-power (three-phase machine) and one low-power machine (single-phase machine). All the proposed solutions have less power devices than the typical solution.
- 1 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 677-682
AC-DC-AC Power Converters with Novel Approach to Power Factor Correction in Three-Phase Systems
The main goal of this paper is to propose three new three-phase to three-phase ac-dc-ac converters, in which the input side is implemented with three-phase three-level PFC rectifier. This rectifier presents some advantages when compared to the two-level rectifier, i.e.: a) operation with high power level; b) reduced voltage harmonics while operating at lower frequency; and c) better quality in the input current waveform. The proposed topologies can operate either with variable output frequency in applications such as ac drive systems, or with fixed output frequency such as UPS (Uninterrupted Power Supply). Experimental results confirm the topologies feasibility. Authors consider the proposed configurations as potentially feasible industrial solutions for applications requiring high power factor at the grid and low THD in the input current waveform, while independently supplying a three-phase load.
- 1 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 677-682
AC-DC-AC Power Converters with Novel Approach to Power Factor Correction in Three-Phase Systems
The main goal of this paper is to propose three new three-phase to three-phase ac-dc-ac converters, in which the input side is implemented with three-phase three-level PFC rectifier. This rectifier presents some advantages when compared to the two-level rectifier, i.e.: a) operation with high power level; b) reduced voltage harmonics while operating at lower frequency; and c) better quality in the input current waveform. The proposed topologies can operate either with variable output frequency in applications such as ac drive systems, or with fixed output frequency such as UPS (Uninterrupted Power Supply). Experimental results confirm the topologies feasibility. Authors consider the proposed configurations as potentially feasible industrial solutions for applications requiring high power factor at the grid and low THD in the input current waveform, while independently supplying a three-phase load.
- 1 February 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition
- No. 10482334,p. 1707-1713
Fault Tolerant AC-AC Single-Phase to Three-Phase DC-Link Converter
A fault tolerant system considering a single-phase to three-phase power conversion has been proposed in this work. Two kinds of failures occurring in the converter power devices, open circuit and short circuit, can be compensated by proposed system. The fault compensation is achieved by reconfiguring the power converter topology with the help of isolation and connection devices. These devices are used to redefine the post-fault converter topology. A proposed control strategy allows to keep the post-fault topology operating at same power rate of the pre-fault one. Simulated and experimental results are presented.
- 1 February 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition
- No. 10482334,p. 1707-1713
Fault Tolerant AC-AC Single-Phase to Three-Phase DC-Link Converter
A fault tolerant system considering a single-phase to three-phase power conversion has been proposed in this work. Two kinds of failures occurring in the converter power devices, open circuit and short circuit, can be compensated by proposed system. The fault compensation is achieved by reconfiguring the power converter topology with the help of isolation and connection devices. These devices are used to redefine the post-fault converter topology. A proposed control strategy allows to keep the post-fault topology operating at same power rate of the pre-fault one. Simulated and experimental results are presented.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (01972618) , 2109-2114
Single-Phase to Three-Phase DC-Link Three-Leg Converter with Minimization of the Capacitor Currents
This article proposes a control technique to reduce the ac fundamental capacitor current of the single-phase to three-phase dc-link three-leg converter. In that technique the converter load voltages are synchronized to the grid voltage. The technique can be used in applications where the load frequency is equal to the input frequency. Experimental and simulated results are presented
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (01972618) , 2109-2114
Single-Phase to Three-Phase DC-Link Three-Leg Converter with Minimization of the Capacitor Currents
This article proposes a control technique to reduce the ac fundamental capacitor current of the single-phase to three-phase dc-link three-leg converter. In that technique the converter load voltages are synchronized to the grid voltage. The technique can be used in applications where the load frequency is equal to the input frequency. Experimental and simulated results are presented