GLGuang Luo

Guang Luo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guang Luo has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study on the shielding efficiency of water, HDPE, and boron-loaded HDPE for neutron background of plastic scintillator neutrino detector

    by DiXiao Lu, YuHang Liu, XueSong Zhang, FengPeng An, Guang Luo, Wei Wang

    Surface-level reactor antineutrino experiments usually have substantial cosmic-ray-induced neutron backgrounds, particularly with shallow overburden. The Array of Lattice for Anti-neutrino Reactor Monitoring (ALARM) is a plastic scintillator-based experiment designed for reactor power monitoring. It will be deployed about 44 m from the core of a reactor at the Taishan Nuclear Power Plant. Placed at a depth of 9.6 meters below the surface, cosmic-ray-induced fast neutrons constitute a significant background, making an effective neutron shielding system essential for the experiment. For the shielding design of ALARM, we tested the shielding performance of three materials — water, HDPE, and 40% boron-doped HDPE (BHDPE) — against both fast and thermal neutrons. A thermal neutron detector composed of an EJ426 scintillator setup was first used to measure the shielding efficiency of these materials at various thicknesses using neutrons from an Am-Be source. A 30-cm thickness of BHDPE achieved a shielding efficiency exceeding 95% for both fast and thermal neutrons. Monte Carlo simulations of the EJ426 setup yielded results consistent with the experimental data. Simulation results for the shielding performance of the full ALARM shielding assembly are also presented.

  • Open Access

    Performance Characterization of a Plastic Scintillator Sensor for Fast Neutron, Thermal Neutron, and Gamma Ray Discrimination

    by Yuhang Liu, Fengpeng An, Guang Luo, Wei Wang, Xuesong Zhang, Dixiao Lu, Xiaohao Yin

    A compact single-PMT composite scintillation detector was developed and characterized for discrimination of γ rays, fast neutrons, and thermal neutrons in mixed radiation fields. The detector assemblies consisted of either EJ200 or EJ276 plastic scintillators optically coupled to an EJ426 thermal neutron screen and read out by a single photomultiplier tube (PMT). The γ−equivalent energy response of the detector assemblies was calibrated using 137Cs, 22Na, and 60Co sources through Compton edge analysis, and pulse shape discrimination was evaluated with an Am–Be neutron source under different moderator thicknesses. The EJ200+EJ426 assembly provides a well-separated discrimination between thermal neutron capture events and γ dominated events over the measured range, with a figure of merit greater than 5. In contrast, the EJ276+EJ426 assembly produced three identifiable signal populations associated with γ rays, fast neutrons, and thermal neutrons. These results show that the proposed sensor architecture is a promising compact approach for mixed-field radiation applications.

  • Open Access

    Development of a dual-phase xenon time projection chamber prototype for the RELICS experiment

    by Lingfeng Xie, Jiajun Liu, Yifei Zhao, Chang Cai, Guocai Chen, Jiangyu Chen, Huayu Dai, Rundong Fang, Hongrui Gao, Fei Gao, et al.

    The RELICS (REactor neutrino LIquid xenon Coherent elastic Scattering) experiment aims to detect coherent elastic neutrino-nucleus scattering from reactor antineutrinos using a dual-phase xenon time projection chamber (TPC). To validate the detector concept and ensure technical reliability for the full-scale experiment, a dedicated prototype was designed, constructed, and operated. This work presents an overview of the design, construction, and operational performance of the prototype, with emphasis on its major subsystems, including the TPC, cryogenics and xenon purification systems, slow control, and data acquisition. During operation, the detector demonstrated the capability to achieve a sub-keV energy threshold required for the RELICS physics program, as reflected by a measured single electron gain of (34.30 ± 0.01 (stat.)) PE/e $$^-$$ - and the successful detection of $$\mathrm {0.27~keV}$$ 0.27 keV L-shell decay events from $$\mathrm {^{37}Ar}$$ 37 Ar . In addition, essential data analysis techniques and simulation frameworks were developed and validated, establishing the technical foundation for future RELICS operations. The successful construction and operation of this prototype confirm the feasibility of the core technologies and provide the experimental basis for the full-scale RELICS detector.

  • Open Access

    Performance and pulse shape discrimination of glass scintillator SG101 for neutron detection

    by Yuhang Liu, Fengpeng An, Guang Luo, Wei Wang, Wei Wei, Xuesong Zhang, Dixiao Lu, Xiaohao Yin

    We present a detailed characterization of the thermal neutron sensitive transparent glass scintillator SG101, benchmarked against the conventional LiF ZnS(Ag)based scintillator EJ426. The detection efficiency, energy resolution, and pulse shape discrimination (PSD) performance ofSG101 were evaluated under AmBe neutron irradiation. When coupled with organic scintillators(EJ200 or EJ276),the SG101 EJ200 system achieves a figure of merit (FOM) of 3.81 for thermal neutron/gamma separation, while the SG101 EJ276 configuration resolves three distinct particle populations gamma rays, fast neutrons, and thermal neutrons with FOM values of 3.46 and2.21, respectively. Correlation analysis reveals that the number of fast thermal neutron coincidence events significantly exceeds the accidental background, and the count of gamma fast thermal neutron triple-coincidence events is also far higher than the expected accidental rate, confirming significant physical correlations for both event types within a 100 us time window. These results demonstrate that SG101 is a promising candidate for applications requiring high-efficiency thermal neutron detection and precise event tagging coupling with a scintillator with PSD approach

  • Open Access

    Study of a triple-discriminating plastic scintillator detector for fast neutrons, thermal neutrons, and gamma rays

    by Y. H. Liu, X. S. Zhang, D. X. Lu, W. Wang, G. Luo, F. P. An

    Detecting fast and thermal neutrons plays a crucial role in neutrino experiments and reactor physics. In this study, we propose a plastic scintillator detector which demonstrates the ability to clearly distinguish fast neutrons, thermal neutrons, and gamma rays within mixed radiation fields, offering a practical approach for multi-radiation detection. Two plastic scintillator assemblies: EJ200+EJ426 and EJ276+EJ426 were setup, and the system energy response was calibrated using three gamma sources(137Cs, 22Na and 60Co). An Am-Be neutron source was employed, and pulse shape discrimination(PSD) was used to separate fast neutrons, thermal neutrons and gamma rays. Using a three-sigma discrimination criterion, the EJ200+EJ426 configuration was found to reliably distinguish thermal neutrons from gamma rays, while the EJ276+EJ426 configuration can effectively discriminate fast neutrons, thermal neutrons and gamma rays at gamma-equivalent energies above 1 MeV.

  • Performance of plastic scintillator modules for top veto tracker at Taishan Antineutrino Observatory

    by Guang Luo, Xiao-Hao Yin, Feng-Peng An, Zhi-Min Wang, Y. K. Hor, Pei-Zhi Lu, Ru-Hui Li, Yi-Chen Li, Wei He, Wei Wang, et al.


  • Design optimization of plastic scintillators with wavelength-shifting fibers and silicon photomultiplier readouts in the top veto tracker of the JUNO-TAO experiment

    by Guang Luo, Y. K. Hor, Pei-Zhi Lu, Zhi-Min Wang, Ru-Hui Li, Min Li, Yi-Chen Li, Liang Zhan, Wei Wang, Yue-Huan Wei, et al.