Christopher D. Spicer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christopher D. Spicer has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Christopher C. Schmidt
Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
2 shared publications - Coline Jumeaux
Department of Materials Department of Bioengineering and Institute of Biomedical Engineering Imperial College London London SW7 2AZ United Kingdom
2 shared publications - Harunur Rashid
Department of Mathematics and Physics, North South University, Dhaka, Bangladesh
2 shared publications - Irene Yarovsky
RMIT University
2 shared publications Joe Nabarro
Department of Chemistry and York Biomedical Research Institute University of York Heslington YO10 5DD United Kingdom
2 shared publicationsLi Ma
Department of Materials Department of Bioengineering and Institute of Biomedical Engineering Imperial College London London SW7 2AZ United Kingdom
2 shared publications
Latest Publications
- Open Access
- 4 March 2024
- Published by Wiley in Angewandte Chemie
- Vol. 136 (14)
Strain‐Promoted Cycloadditions in Lipid Bilayers Triggered by Liposome Fusion
Due to the variety of roles served by the cell membrane, its composition and structure are complex, making it difficult to study. Bioorthogonal reactions, such as the strain promoted azide‐alkyne cycloaddition (SPAAC), are powerful tools for exploring the function of biomolecules in their native environment but have been largely unexplored within the context of lipid bilayers. Here, we developed a new approach to study the SPAAC reaction in liposomal membranes using azide‐ and strained alkyne‐functionalized Förster resonance energy transfer (FRET) dye pairs. This study represents the first characterization of the SPAAC reaction between diffusing molecules inside liposomal membranes. Potential applications of this work include in situ bioorthogonal labeling of membrane proteins, improved understanding of membrane dynamics and fluidity, and the generation of new probes for biosensing assays.
- 4 March 2024
- Published by Wiley in Angewandte Chemie
- Vol. 136 (14)
Open AccessStrain‐Promoted Cycloadditions in Lipid Bilayers Triggered by Liposome Fusion
Due to the variety of roles served by the cell membrane, its composition and structure are complex, making it difficult to study. Bioorthogonal reactions, such as the strain promoted azide‐alkyne cycloaddition (SPAAC), are powerful tools for exploring the function of biomolecules in their native environment but have been largely unexplored within the context of lipid bilayers. Here, we developed a new approach to study the SPAAC reaction in liposomal membranes using azide‐ and strained alkyne‐functionalized Förster resonance energy transfer (FRET) dye pairs. This study represents the first characterization of the SPAAC reaction between diffusing molecules inside liposomal membranes. Potential applications of this work include in situ bioorthogonal labeling of membrane proteins, improved understanding of membrane dynamics and fluidity, and the generation of new probes for biosensing assays.
- Open Access
- 4 March 2024
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 63 (14) , e202314786
Strain‐Promoted Cycloadditions in Lipid Bilayers Triggered by Liposome Fusion
Due to the variety of roles served by the cell membrane, its composition and structure are complex, making it difficult to study. Bioorthogonal reactions, such as the strain promoted azide‐alkyne cycloaddition (SPAAC), are powerful tools for exploring the function of biomolecules in their native environment but have been largely unexplored within the context of lipid bilayers. Here, we developed a new approach to study the SPAAC reaction in liposomal membranes using azide‐ and strained alkyne‐functionalized Förster resonance energy transfer (FRET) dye pairs. This study represents the first characterization of the SPAAC reaction between diffusing molecules inside liposomal membranes. Potential applications of this work include in situ bioorthogonal labeling of membrane proteins, improved understanding of membrane dynamics and fluidity, and the generation of new probes for biosensing assays.
- 4 March 2024
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 63 (14) , e202314786
Open AccessStrain‐Promoted Cycloadditions in Lipid Bilayers Triggered by Liposome Fusion
Due to the variety of roles served by the cell membrane, its composition and structure are complex, making it difficult to study. Bioorthogonal reactions, such as the strain promoted azide‐alkyne cycloaddition (SPAAC), are powerful tools for exploring the function of biomolecules in their native environment but have been largely unexplored within the context of lipid bilayers. Here, we developed a new approach to study the SPAAC reaction in liposomal membranes using azide‐ and strained alkyne‐functionalized Förster resonance energy transfer (FRET) dye pairs. This study represents the first characterization of the SPAAC reaction between diffusing molecules inside liposomal membranes. Potential applications of this work include in situ bioorthogonal labeling of membrane proteins, improved understanding of membrane dynamics and fluidity, and the generation of new probes for biosensing assays.
- Open Access
- 27 April 2022
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 104 (14) , 1292-1300
The Rotator Cable Does Not Stress Shield the Crescent Area During Shoulder Abduction
Background: It is accepted by the orthopaedic community that the rotator cable (RCa) acts as a suspension bridge that stress shields the crescent area (CA). The goal of this study was to determine if the RCa does stress shield the CA during shoulder abduction. Methods: The principal strain magnitude and direction in the RCa and CA and shoulder abduction force were measured in 20 cadaveric specimens. Ten specimens underwent a release of the anterior cable insertion followed by a posterior release. In the other 10, a release of the posterior cable insertion was followed by an anterior release. Testing was performed for the native, single-release, and full-release conditions. The thicknesses of the RCa and CA were measured. Results: Neither the principal strain magnitude nor the strain direction in either the RCa or the CA changed with single or full RCa release (p ≥ 0.493). There were no changes in abduction force after single or full RCa release (p ≥ 0.180). The RCa and CA thicknesses did not differ from one another at any location (p ≥ 0.195). Conclusions: The RCa does not act as a suspension bridge and does not stress shield the CA. The CA primarily transfers shoulder abduction force to the greater tuberosity. Clinical Relevance: The CA is important in force transmission during shoulder abduction, and efforts should be made to restore its continuity with a repair or reconstruction.
- 27 April 2022
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 104 (14) , 1292-1300
Open AccessThe Rotator Cable Does Not Stress Shield the Crescent Area During Shoulder Abduction
Background: It is accepted by the orthopaedic community that the rotator cable (RCa) acts as a suspension bridge that stress shields the crescent area (CA). The goal of this study was to determine if the RCa does stress shield the CA during shoulder abduction. Methods: The principal strain magnitude and direction in the RCa and CA and shoulder abduction force were measured in 20 cadaveric specimens. Ten specimens underwent a release of the anterior cable insertion followed by a posterior release. In the other 10, a release of the posterior cable insertion was followed by an anterior release. Testing was performed for the native, single-release, and full-release conditions. The thicknesses of the RCa and CA were measured. Results: Neither the principal strain magnitude nor the strain direction in either the RCa or the CA changed with single or full RCa release (p ≥ 0.493). There were no changes in abduction force after single or full RCa release (p ≥ 0.180). The RCa and CA thicknesses did not differ from one another at any location (p ≥ 0.195). Conclusions: The RCa does not act as a suspension bridge and does not stress shield the CA. The CA primarily transfers shoulder abduction force to the greater tuberosity. Clinical Relevance: The CA is important in force transmission during shoulder abduction, and efforts should be made to restore its continuity with a repair or reconstruction.
- 25 January 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (9) , 812-819
Partial Distal Biceps Avulsion Results in a Significant Loss of Supination Force
Background: Partial avulsions of the short and/or long head of the distal biceps tendon cause pain and loss of strength. The goal of the present study was to quantify the loss of supination and flexion strength following a series of surgical releases designed to simulate partial and complete short and long head traumatic avulsions. Methods: Mechanical testing was performed to measure supination moment arms and flexion force efficiency on 18 adult fresh-frozen specimens in pronation, neutral, and supination. The distal biceps footprint length was divided into 4 equal segments. In 9 specimens (the distal-first group), the tendon was partially cut starting distally by releasing 25%, 50%, and 75% of the insertion site. In the other 9 specimens (the proximal-first group), the releases started proximally. Mechanical testing was performed before and after each release. Results: Significant decreases in the supination moment arm occurred after a 75% release in the distal-first release group; the decrease was 24% in pronation (p = 0.003) and 10% in neutral (p = 0.043). No significant differences in the supination moment arm (p ≥ 0.079) or in flexion force efficiency (p ≥ 0.058) occurred in the proximal-first group. Conclusions: A simulated complete short head avulsion significantly decreased the supination moment arm and therefore supination strength. Clinical Relevance: A mechanical case can be made for repair of partial distal biceps tendon avulsions when the rupture involves ≥75% of the distal insertion site.
- 25 January 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (9) , 812-819
Partial Distal Biceps Avulsion Results in a Significant Loss of Supination Force
Background: Partial avulsions of the short and/or long head of the distal biceps tendon cause pain and loss of strength. The goal of the present study was to quantify the loss of supination and flexion strength following a series of surgical releases designed to simulate partial and complete short and long head traumatic avulsions. Methods: Mechanical testing was performed to measure supination moment arms and flexion force efficiency on 18 adult fresh-frozen specimens in pronation, neutral, and supination. The distal biceps footprint length was divided into 4 equal segments. In 9 specimens (the distal-first group), the tendon was partially cut starting distally by releasing 25%, 50%, and 75% of the insertion site. In the other 9 specimens (the proximal-first group), the releases started proximally. Mechanical testing was performed before and after each release. Results: Significant decreases in the supination moment arm occurred after a 75% release in the distal-first release group; the decrease was 24% in pronation (p = 0.003) and 10% in neutral (p = 0.043). No significant differences in the supination moment arm (p ≥ 0.079) or in flexion force efficiency (p ≥ 0.058) occurred in the proximal-first group. Conclusions: A simulated complete short head avulsion significantly decreased the supination moment arm and therefore supination strength. Clinical Relevance: A mechanical case can be made for repair of partial distal biceps tendon avulsions when the rupture involves ≥75% of the distal insertion site.