Abstract
Background: Partial avulsions of the short and/or long head of the distal biceps tendon cause pain and loss of strength. The goal of the present study was to quantify the loss of supination and flexion strength following a series of surgical releases designed to simulate partial and complete short and long head traumatic avulsions. Methods: Mechanical testing was performed to measure supination moment arms and flexion force efficiency on 18 adult fresh-frozen specimens in pronation, neutral, and supination. The distal biceps footprint length was divided into 4 equal segments. In 9 specimens (the distal-first group), the tendon was partially cut starting distally by releasing 25%, 50%, and 75% of the insertion site. In the other 9 specimens (the proximal-first group), the releases started proximally. Mechanical testing was performed before and after each release. Results: Significant decreases in the supination moment arm occurred after a 75% release in the distal-first release group; the decrease was 24% in pronation (p = 0.003) and 10% in neutral (p = 0.043). No significant differences in the supination moment arm (p ≥ 0.079) or in flexion force efficiency (p ≥ 0.058) occurred in the proximal-first group. Conclusions: A simulated complete short head avulsion significantly decreased the supination moment arm and therefore supination strength. Clinical Relevance: A mechanical case can be made for repair of partial distal biceps tendon avulsions when the rupture involves ≥75% of the distal insertion site.Keywords
This publication has 33 references indexed in Scilit:
- Isolated short head component rupture of a bifurcated distal biceps tendon mimicking as a complete ruptureJournal of Hand Surgery (European Volume), 2011
- Surgical Treatment of Partial Distal Biceps Tendon RupturesThe Journal of Hand Surgery, 2010
- Bifid insertion of the distal biceps brachii tendon with isolated rupture: Magnetic resonance findingsJournal of Shoulder and Elbow Surgery, 2009
- Distal biceps brachii tendon anatomy revisited from a surgical perspectiveClinical Anatomy, 2009
- Anatomy of the Distal Biceps Brachii Tendon and Its Clinical RelevanceClinical Orthopaedics and Related Research, 2007
- Surgical treatment of partial biceps tendon ruptures at the elbowJournal of Shoulder and Elbow Surgery, 2006
- Surgical treatment of partial distal biceps tendon ruptures through a single posterior incisionJournal of Shoulder and Elbow Surgery, 2003
- Partial Rupture of the Distal Biceps TendonClinical Orthopaedics and Related Research, 2000
- Partial rupture of the distal biceps tendonJournal of Shoulder and Elbow Surgery, 1996
- The distal biceps tendonJournal of Shoulder and Elbow Surgery, 1995