SWSheng Wang

Sheng Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sheng Wang has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Ai-Min Wu

    From the Department of Spinal Surgery (A-MW, HX, H-MJ, Z-YH, Q-BL, SW, H-ZX, Y-LC), Second Affiliated Hospital of Wenzhou Medical University, Zhejiang Spinal Research Center, Wenzhou, Zhejiang, People's Republic of China; and Department of Orthopaedic Surgery (KPM), Orthopaedic Spinal Research Institute, University of Maryland St Joseph Medical Center, Towson, MD, USA

    2 shared publications
  • Hua-Zi Xu

    2 shared publications
  • Xiaolei Zhang

    Department of Orthopaedics, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, Zhejiang Province, China; Zhejiang Provincial Key Laboratory of Orthopedics, Wenzhou, Zhejiang Province, China; The Second School of Medicine, Wenzhou Medical University, Wenzhou, Zhejiang Province, China

    2 shared publications
  • Chenchao Li

    Department of Orthopaedics, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China

    1 shared publication
  • Chenyu Wu

    Department of Orthopaedics, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China

    1 shared publication
  • Cong Xu

    Department of Orthopaedics, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China

    1 shared publication

Latest Publications

  • 20-Deoxyingenol Activates Mitophagy Through TFEB and Promotes Functional Recovery After Spinal Cord Injury

    by Chenyu Wu, Yu Chen, Ximiao Chen, Yekai Zhang, Xiaoying Zhao, Yuxin Deng, Chenchao Li, Di Zhang, Xiaolei Zhang, Sheng Wang

    Spinal cord injury (SCI) can lead to permanent paralysis and various motor, sensory and autonomic nervous system dysfunction. The complex pathophysiological processes limit the effectiveness of many clinical treatments. Mitochondria has been reported to play a key role in the pathogenesis of SCI; while mitophagy is a protective mechanism against mitochondrial dysfunction. However, there is recently little drugs that may targeted activate mitophagy to treat SCI. In this study, we evaluated the role of 20-Deoxyingenol (20-DOI) in SCI and explored its potential mechanisms. We used a SCI rat model and evaluated the functional outcomes after the injury. Western blotting and immunofluorescence techniques were used to analyze the levels of mitophagy, apoptosis, and TFEB-related signaling pathways. Our research results show that 20-DOI significantly improves the apoptosis of neural cells after TBHP stimulation and functional recovery after spinal cord injury. In addition, mitophagy, TFEB levels, and apoptosis are related to the mechanism of 20-DOI treatment for spinal cord injury. Specifically, our research results indicate that 20-DOI restored the autophagic flux after injury, thereby inducing mitophagy, eliminating the accumulation of Cyto C, and inhibiting apoptosis. Further mechanism research suggests that 20-DOI may regulate mitophagy by promoting TFEB nuclear translocation. These results indicate that 20-DOI can significantly promote recovery after spinal cord injury, which may be a promising treatment method for spinal cord injury.


  • Open Access

    CO-Releasing Molecule (CORM)-3 Ameliorates Spinal Cord-Blood Barrier Disruption Following Injury to the Spinal Cord

    by Gang Zheng, Fanghong Zheng, Zucheng Luo, Haiwei Ma, Dongdong Zheng, Guangheng Xiang, Cong Xu, Yifei Zhou, Yaosen Wu, Naifeng Tian, et al.

    Spinal cord injury (SCI) is a clinical tough neurological problem without efficient cure currently. Blood-spinal cord barrier (BSCB) interruption is not only a crucial pathological feature for SCI process but is a possible target for future SCI treatments; however, few treatments have been developed to intervene BSCB. In the present study, we intravenously injected CO-releasing molecule3 (CORM-3), a classical exogenous CO donor, to the rats experiencing SCI and assessed its protection on BSCB integrity in rats. Our results demonstrated that the exogenous increasing of CO by CORM-3 blocked the tight junction (TJ) protein degeneration and neutrophils infiltration, subsequently suppressed the BSCB damage and improved the motor recovery after SCI. And we certified that the CO-induced down-regulation of MMP-9 expression and activity in neutrophil might be associated with the NF-κB signaling. Taken together, our study indicates that CO-releasing molecule (CORM)-3 ameliorates BSCB after spinal cord injury.


  • Open Access

    Minimum 4-Year Outcomes of Cervical Total Disc Arthroplasty Versus Fusion

    by Ai-Min Wu, Hui Xu, Kenneth Paul Mullinix, Hai-Ming Jin, Zhe-Yu Huang, Qing-Bo Lv, Sheng Wang, Hua-Zi Xu, Yong-Long Chi

    The prevalence of cervical disc disease is high, and the traditional surgical method of anterior cervical discectomy and fusion (ACDF) carries with it the disadvantages of motion loss at the operated level, and accelerated adjacent level disc degeneration. Preliminary results of the efficacy and reoperative rate comparing TDA versus ACDF have been reported; however, the long-term outcomes of TDA versus ACDF still remain a topic of debate. This review was prepared following the standard procedures set forth by the Cochrane Collaboration organization, and preferred reporting items for systematic reviews and meta-analyses (PRISMA). The only studies included were randomized controlled trials with a minimum of 4 years of follow-up data. The meta-analysis included the neck disability index (NDI), visual analog scale (VAS) of neck and arm pain, SF-36 physical component scores (SF-36 PCS), over success, neurological success, work status, implant-related complications, and secondary surgery events. Four randomized controlled trials meet the inclusion criteria. The long-term improvement of NDI, VAS of neck and arm pain, SF-36 PCS, over success, and neurological success favored the TDA group. The TDA group also had a lower incidence of secondary surgery for both the index level (RR: 0.45 [0.28, 0.72]) and adjacent level (RR: 0.53 [0.33, 0.88]). In this meta-analysis of 4 included RCTs with a minimum 4 years of follow-ups, total disc arthroplasty showed improvements over ACDF as measured by the NDI, VAS of neck and arm pain, and SF-36 PCS.


  • Open Access

    The Radiological Feature of Anterior Occiput-to-Axis Screw Fixation as it Guides the Screw Trajectory on 3D Printed Models

    by Ai-Min Wu, Sheng Wang, Wan-Qing Weng, Zhen-Xuan Shao, Xin-Dong Yang, Jian-Shun Wang, Hua-Zi Xu, Yong-Long Chi

    Anterior occiput-to-axis screw fixation is more suitable than a posterior approach for some patients with a history of posterior surgery. The complex osseous anatomy between the occiput and the axis causes a high risk of injury to neurological and vascular structures, and it is important to have an accurate screw trajectory to guide anterior occiput-to-axis screw fixation. Thirty computed tomography (CT) scans of upper cervical spines were obtained for three-dimensional (3D) reconstruction. Cylinders (1.75 mm radius) were drawn to simulate the trajectory of an anterior occiput-to-axis screw. The imitation screw was adjusted to 4 different angles and measured, as were the values of the maximized anteroposterior width and the left-right width of the occiput (C0) to the C1 and C1 to C2 joints. Then, the 3D models were printed, and an angle guide device was used to introduce the screws into the 3D models referring to the angles calculated from the 3D images. We found the screw angle ranged from α1 (left: 4.99 ± 4.59°; right: 4.28 ± 5.45°) to α2 (left: 20.22 ± 3.61°; right: 19.63 ± 4.94°); on the lateral view, the screw angle ranged from β1 (left: 13.13 ± 4.93°; right: 11.82 ± 5.64°) to β2 (left: 34.86 ± 6.00°; right: 35.01 ± 5.77°). No statistically significant difference was found between the data of the left and right sides. On the 3D printed models, all of the anterior occiput-to-axis screws were successfully introduced, and none of them penetrated outside of the cortex; the mean α4 was 12.00 ± 4.11 (left) and 12.25 ± 4.05 (right), and the mean β4 was 23.44 ± 4.21 (left) and 22.75 ± 4.41 (right). No significant difference was found between α4 and β4 on the 3D printed models and α3 and β3 calculated from the 3D digital images of the left and right sides. Aided with the angle guide device, we could achieve an optimal screw trajectory for anterior occiput-to-axis screw fixation on 3D printed C0 to C2 models.