The Radiological Feature of Anterior Occiput-to-Axis Screw Fixation as it Guides the Screw Trajectory on 3D Printed Models
Open Access
- 1 December 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine
- Vol. 93 (28) , e242
Abstract
Anterior occiput-to-axis screw fixation is more suitable than a posterior approach for some patients with a history of posterior surgery. The complex osseous anatomy between the occiput and the axis causes a high risk of injury to neurological and vascular structures, and it is important to have an accurate screw trajectory to guide anterior occiput-to-axis screw fixation. Thirty computed tomography (CT) scans of upper cervical spines were obtained for three-dimensional (3D) reconstruction. Cylinders (1.75 mm radius) were drawn to simulate the trajectory of an anterior occiput-to-axis screw. The imitation screw was adjusted to 4 different angles and measured, as were the values of the maximized anteroposterior width and the left-right width of the occiput (C0) to the C1 and C1 to C2 joints. Then, the 3D models were printed, and an angle guide device was used to introduce the screws into the 3D models referring to the angles calculated from the 3D images. We found the screw angle ranged from α1 (left: 4.99 ± 4.59°; right: 4.28 ± 5.45°) to α2 (left: 20.22 ± 3.61°; right: 19.63 ± 4.94°); on the lateral view, the screw angle ranged from β1 (left: 13.13 ± 4.93°; right: 11.82 ± 5.64°) to β2 (left: 34.86 ± 6.00°; right: 35.01 ± 5.77°). No statistically significant difference was found between the data of the left and right sides. On the 3D printed models, all of the anterior occiput-to-axis screws were successfully introduced, and none of them penetrated outside of the cortex; the mean α4 was 12.00 ± 4.11 (left) and 12.25 ± 4.05 (right), and the mean β4 was 23.44 ± 4.21 (left) and 22.75 ± 4.41 (right). No significant difference was found between α4 and β4 on the 3D printed models and α3 and β3 calculated from the 3D digital images of the left and right sides. Aided with the angle guide device, we could achieve an optimal screw trajectory for anterior occiput-to-axis screw fixation on 3D printed C0 to C2 models.Keywords
This publication has 18 references indexed in Scilit:
- Percutaneous anterior occiput-to-axis screw fixation: technique aspects and case seriesThe Spine Journal, 2013
- A systematic review of occipital cervical fusion: techniques and outcomesJournal of Neurosurgery: Spine, 2010
- SURGICAL TREATMENT OF OCCIPITOCERVICAL INSTABILITYNeurosurgery, 2008
- Evolution of posterior cervical and occipitocervical fusion and instrumentationNeurosurgical Focus, 2004
- Lateral mass screw–rod fixation of the cervical spine: a prospective clinical series with 1-year follow-upThe Spine Journal, 2003
- Anterior Occiput to Axis Screw FixationSpine, 2003
- Anterior Occiput-to-Axis Screw FixationSpine, 2003
- Posterior occipitocervical fusion in rheumatoid arthritis and other instabilitiesJournal of Orthopaedic Science, 2000
- Posterior Occipitocervical Reconstruction Using Cervical Pedicle Screws and Plate–Rod SystemsSpine, 1999
- Anatomic Considerations of Anterior Transarticular Screw Fixation for Atlantoaxial InstabilitySpine, 1998