Valentina Casieri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Valentina Casieri has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Vincenzo Lionetti
Master II level Underwater and Hyperbaric Medicine “Piergiorgio Data”, Scuola Superiore Sant’Anna, TrancriLab, Laboratory of Basic and Applied Medical Research, Interdisciplinary Research Center "Health Science", Scuola Superiore Sant'Anna, Italy.;, UOSVD Anesthesia and Intensive Care, Fondazione Toscana “G. Monasterio”, Pisa, Italy, Italy
3 shared publications - Anar Dushpanova
Al-Fabari Kazakh National University, al-Farabi avenue 71, Almaty, Kazakhstan, 050040
2 shared publications - Ciro Zinno
BioRobotics Institute, Department of Excellence in Robotics and AI, Scuola Superiore Sant’Anna, 56025 Pontedera, Italy
2 shared publications - Khatia Gabisonia
BioMedLab, Interdisciplinary Research Center “Health Science,” Scuola Superiore Sant’Anna, 56124 Pisa, Italy
2 shared publications - Silvestro Micera
The Biorobotics Institute and Department of Excellence in Robotics & AI, Scuola Superiore Sant’Anna, Pisa, Italy
2 shared publications - Alessandro Carrozzo
Maria Cecilia Hospital, GVM Care and Research, 48033 Cotignola, Italy
1 shared publication
Latest Publications
- 24 December 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 17 (830) , eaea4306
Reconnecting the vagus nerve to the heart through nerve conduit preserves cardiac function in a minipig model of right cardiac vagotomy
The right vagus nerve is essential for cardiac homeostasis, and its intrathoracic resection can lead to postoperative cardiac complications. Strategies to restore vagal innervation after transection at the cardiac level remain lacking. Here, we show that early reconnection of the right vagus nerve using an implantable chitosan/poly-ε-caprolactone cuff-like nerve guidance conduit preserved cardiac mechanical function in adult male minipigs subjected to right cardiac vagotomy. Treated animals displayed improved global circumferential, longitudinal, and radial strains and reduced diastolic dyssynchrony. Histological analysis revealed partial repair with about 20% viable vagal fascicles, restoration of myocardial parasympathetic fibers, normalization of oxidative stress and aging markers, and prevention of interstitial fibrosis. These findings suggest that maintaining even limited vagal input prevents early cardiac remodeling by mitigating oxidative stress–induced premature senescence of cardiac cells. Reconnection of the right vagus nerve with chitosan/poly-ε-caprolactone cuff-like nerve guidance conduit may represent a therapeutic approach to preventing right vagotomy–induced heart failure after thoracic surgery or cardiothoracic transplantation.
- 24 December 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 17 (830) , eaea4306
Reconnecting the vagus nerve to the heart through nerve conduit preserves cardiac function in a minipig model of right cardiac vagotomy
The right vagus nerve is essential for cardiac homeostasis, and its intrathoracic resection can lead to postoperative cardiac complications. Strategies to restore vagal innervation after transection at the cardiac level remain lacking. Here, we show that early reconnection of the right vagus nerve using an implantable chitosan/poly-ε-caprolactone cuff-like nerve guidance conduit preserved cardiac mechanical function in adult male minipigs subjected to right cardiac vagotomy. Treated animals displayed improved global circumferential, longitudinal, and radial strains and reduced diastolic dyssynchrony. Histological analysis revealed partial repair with about 20% viable vagal fascicles, restoration of myocardial parasympathetic fibers, normalization of oxidative stress and aging markers, and prevention of interstitial fibrosis. These findings suggest that maintaining even limited vagal input prevents early cardiac remodeling by mitigating oxidative stress–induced premature senescence of cardiac cells. Reconnection of the right vagus nerve with chitosan/poly-ε-caprolactone cuff-like nerve guidance conduit may represent a therapeutic approach to preventing right vagotomy–induced heart failure after thoracic surgery or cardiothoracic transplantation.
- Open Access
Neural stimulation hardware for the selective intrafascicular modulation of the vagus nerve
The neural stimulation of the vagus nerve is able to modulate various functions of the parasympathetic response in different organs. The stimulation of the vagus nerve is a promising approach to treating inflammatory diseases, obesity, diabetes, heart failure, and hypertension. The complexity of the vagus nerve requires highly selective stimulation, allowing the modulation of target-specific organs without side effects. Here, we address this issue by adapting a neural stimulator and developing an intraneural electrode for the particular modulation of the vagus nerve. The neurostimulator parameters such as amplitude, pulse width, and pulse shape were modulated. Single-, and multi-channel stimulation was performed at different amplitudes. For the first time, I polyimide thin-film neural electrode was designed for the specific stimulation of the vagus nerve. In vivo experiments were performed in the adult minipig to validate to elicit electrically evoked action potentials and to modulate physiological functions selectively, validating the selectivity of intraneural stimulation. Electrochemical tests of the electrode and the neurostimulator showed that the stimulation hardware was working correctly. Stimulating the porcine vagus nerve resulted in selective modulation of the vagus nerve. Alpha, beta, and theta waves could be distinguished during single- and multi-channel stimulation. We have shown that the here presented system is able to activate the vagus nerve selectively and can therefore modulate the heart rate, diastolic pressure, and systolic pressure. The here presented system may be used to restore the cardiac loop after denervation by implementing biomimetic stimulation patterns. Presented methods may be used to develop intraneural electrodes adapted for various applications.
Open AccessNeural stimulation hardware for the selective intrafascicular modulation of the vagus nerve
The neural stimulation of the vagus nerve is able to modulate various functions of the parasympathetic response in different organs. The stimulation of the vagus nerve is a promising approach to treating inflammatory diseases, obesity, diabetes, heart failure, and hypertension. The complexity of the vagus nerve requires highly selective stimulation, allowing the modulation of target-specific organs without side effects. Here, we address this issue by adapting a neural stimulator and developing an intraneural electrode for the particular modulation of the vagus nerve. The neurostimulator parameters such as amplitude, pulse width, and pulse shape were modulated. Single-, and multi-channel stimulation was performed at different amplitudes. For the first time, I polyimide thin-film neural electrode was designed for the specific stimulation of the vagus nerve. In vivo experiments were performed in the adult minipig to validate to elicit electrically evoked action potentials and to modulate physiological functions selectively, validating the selectivity of intraneural stimulation. Electrochemical tests of the electrode and the neurostimulator showed that the stimulation hardware was working correctly. Stimulating the porcine vagus nerve resulted in selective modulation of the vagus nerve. Alpha, beta, and theta waves could be distinguished during single- and multi-channel stimulation. We have shown that the here presented system is able to activate the vagus nerve selectively and can therefore modulate the heart rate, diastolic pressure, and systolic pressure. The here presented system may be used to restore the cardiac loop after denervation by implementing biomimetic stimulation patterns. Presented methods may be used to develop intraneural electrodes adapted for various applications.
- 18 December 2015
- Published by Springer Nature
- p. 111-122
Epigenetic Regulation of Cardiac Regeneration