JVJesús Velázquez

Jesús Velázquez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jesús Velázquez has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of a telescopic simultaneous ballbar in a 3-axis machine tool using a reference equipment

    by Raquel Acero, Francisco Javier Brosed, Marcos Pueo, Sergio Aguado, Juan José Aguilar, Jesús Velazquez


  • Open Access

    Study on LT Accuracy Improvement by Calibration Based on Network Measurements

    by Jesús Velázquez, Javier Conte, Ana Cristina Majarena, Jorge Santolaria

    Laser trackers (LT) are widely used to calibrate other machines. Nevertheless, very little is known about calibrating an LT. There are some standards that allow us to evaluate the LT performance. However, they require specialized equipment. A calibration procedure to improve the LT accuracy in an easy and fast way is presented in this paper. This method is based on network measurements where a set of reflectors were measured from different LT positions in a working environment. The methodology proposed deal with the lack of nominal data of the reflector mesh. A measurement scenario was defined, based on error parameter dependence on distances and angles, thus, obtaining those positions more sensitive to errors. The influence of the incidence angle of the laser beam on the reflector was characterized, revealing that its contribution to the LT measurement error can be up to 13 µm. Error kinematic parameters were identified to provide the optimum value of an objective function, where the reflector mesh nominal data were unknown. The calibration procedure was validated with nominal data, by measuring a set of reflectors located on a coordinate measuring machine. The findings of this study suggested that the LT accuracy can be improved up to 25%. Moreover, the method can be carried out by the LT user without requiring specialized equipment.


  • Open Access

    Configuration Optimisation of Laser Tracker Location on Verification Process

    by Sergio Aguado, Pablo Pérez, José Antonio Albajez, Jorge Santolaria, Jesús Velázquez

    Machine tools are verified and compensated periodically to improve accuracy. The main aim of machine tool verification is to reduce the influence of quasi-static errors, especially geometric errors. As these errors show systematic behavior, their influence can be compensated. However, verification itself is influenced by random uncertainty sources that are usually not considered but affect the results. Within these uncertainty sources, laser tracker measurement noise is a random error that should not be ignored and can be reduced through adequate location of the equipment. This paper presents an algorithm able to analyse the influence of laser tracker location based on nonlinear optimisation, taking into consideration its specifications and machine tool characteristics. The developed algorithm uses the Monte Carlo method to provide a zone around the machine tool where the measurement system should be located in order to improve verification results. To achieve this aim, different parameters were defined, such as the number of tests carried out, and the number and distribution of points, and their influence on the error due to the laser tracker location analysed.


  • Open Access

    Study on Machine Tool Positioning Uncertainty Due to Volumetric Verification

    by Sergio Aguado, Pablo Pérez, José Antonio Albajez, Jorge Santolaria, Jesús Velazquez

    Volumetric verification is based on the machine tool (MT) kinematic model, along with its geometric errors. Although users often ignore the uncertainty of verification, the use of the MT as a traceable measurement system in the manufacturing process has increased the need for professionals to be aware of it. This paper presents an improvement in the MT kinematic model, introducing in it the influence of verification uncertainty sources. These sources have been classified into four groups: the MT, the measurement system itself, the measurement strategy, and the optimization strategy. As the developed model exhibits non-linear behavior, the Monte Carlo method was used to determine the influence of the measurement system on verification uncertainty using synthetic tests. In this manner, an improved estimation of the MT uncertainty can be obtained. Therefore, if the MT is used as a traceable measurement system, its accuracy should not be higher than the laser tracker (LT) verification influence. It hence shows the importance of LT influence.


  • Improving a real milling machine accuracy through an indirect measurement of its geometric errors

    by Sergio Aguado, Jorge Santolaria, David Samper, Juan J. Aguilar, Jesús Velázquez


  • Open Access

    Adequacy of Technical and Commercial Alternatives Applied to Machine Tool Verification Using Laser Tracker

    by Sergio Aguado, Jorge Santolaria, David Samper, Jesús Velázquez, Carlos Javierre, Ángel Fernández

    Besides presenting a volumetric verification technique that allows characterization of the different geometric errors of a machine tool (MT) depending on its kinematic chain and geometry through a kinematic model, this paper investigates the influence of measurement tools and techniques available on the final accuracy of the MT. Volumetric verification based on a laser tracker (LT) relates the coordinates of the tool with the coordinates of the LT, including it into the kinematic model. Using a non-lineal optimization process, approximation functions that characterize the joint influence of MT geometric errors are obtained. However, measurement data will be affected by previous compensation of the MT, the accuracy of the measurement system, LT measurement technology, the type of retroreflector used, and techniques used to improve data accuracy, among other sources of errors. This paper studies the adequacy of different commercial alternatives such as: retroreflectors, LTs from different manufacturers, etc., that can be applied in MT verification using a long-range MT. As the accuracy is strongly affected by the uncertainty of its angular encoders, the multilateration technique tries to improve data accuracy using only LT radial information. Nonetheless, a new bundle adjustment which uses radial and angular information is presented in current metrology software. This paper studies both techniques and analyzes their adequacy for MT verification too.


  • Empirical analysis of the efficient use of geometric error identification in a machine tool by tracking measurement techniques

    by S Aguado, J Santolaria, D Samper, J Velazquez, J J Aguilar

    Volumetric verification is becoming increasingly accepted as a suitable technique with which to improve machine tool accuracy. In the same way, the use of laser trackers to obtain machine error information using the new Active Target motorised retro-reflector allows the verification of all types of machine tool throughout their workspaces. Non-linear optimisation methods and machine tool kinematic models are the mainstays of this technique. Whereas the latter provide the relationship between the nominal coordinates, the geometric errors of the machine and laser tracker measurement, the former reduces the combined influence of geometric errors by obtaining their approximation functions. However, within these two procedures, several factors affect the scope of the produced verification results. The present paper focuses on the analysis of the adequacy of commercial measurement techniques using laser trackers and the new motorised retro-reflector in a real milling machine. An examination is also made regarding the influence of the optimisation sequence defined by the identification strategy, as well as the impact of the number of measured points in relation to the employed regression functions.


  • Efficient volumetric error compensation technique for additive manufacturing machines

    by Carlos Cajal, Jorge Santolaria, David Samper, Jesus Velazquez

    Purpose: – This paper aims to present a methodology for volumetric error compensation. This technique is applied to an Objet Eden350V 3D printer and involves a custom measurement strategy. Design/methodology/approach: – The kinematic model of the printer is explained, and its error model is simplified to 18 independent error functions. Each error function is defined by a cubic Legendre polynomial. The coefficients of the polynomials are obtained through a Levenberg–Marquardt optimization process. This optimization process compares, in an iterative algorithm, nominal coordinates with actual values of the cloud of points. The points are built in the faces of a gauge artefact as conical sockets defining one unique point for each socket. These points are measured by a coordinate measuring machine self-centring measurement process. Findings: – Most of the errors of the 3D printer are systematic. It is possible to obtain an improvement of 70 per cent in terms of global mean error reduction in single points within a volume of 120 × 120 × 40 mm. The forecast of the final error compensation fully matches the actual final error. Practical implications: – This methodology can be used for accuracy improvement in additive manufacturing machines. Originality/value: – Unlike the calculation of geometric errors, the proposed parametric determination through optimization of the error model allows global error reduction, which decreases all sort of systematic errors concurrently. The proposed measurement strategy allows high reliability, high speed and operator independence in the measurement process, which increases efficiency and reduces the cost. The proposed methodology is easily translated to other rapid prototyping machines and allows scalability when replicating artefacts covering any working volume.