HAHussein Al-Quraishi

Hussein Al-Quraishi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hussein Al-Quraishi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigation of Sealing Materials for Sewer Pipe Connections to Concrete Manholes

    by Haneen K. Al-Oqaili, Hussein Al-Quraishi, Faaeza A. Abdulkareem

    Concrete manholes are a fundamental component of wastewater management systems. Manholes are among the most essential elements of wastewater management systems. The sections connected to the structure are often the least protected among the piping units. Due to heavy surface loads and traffic, these connections are prone to failure and can easily collapse. This research paper aims to use materials that ensure effective connections and prevent contaminated water from leaking into the environment. The study used advanced cementitious and mechanical waterproofing materials. Additionally, a 25-centimeter diameter pipe was employed. Due to the widespread use of conventional cement, fly ash was added as a supplementary cementitious material at a specified percentage of the cement weight to reduce cement consumption. Tests are conducted to examine the material’s resistance. The results showed that the leakage rate for the first method was 1%, while the reference method was 10.9%. Methods 2 and 3, 0.81% and 0.64%, respectively. This study examined the compressive strength of cementitious materials to determine their load-bearing capacity. The results showed that Method 2 achieved a load-bearing capacity of 2.7, while Method 3 achieved 9.9, and the reference method reached approximately 2.9. Method 3 can be adopted for specific environments. The study found that using advanced materials with superior mechanical properties that achieve high leakage resistance demonstrated high effectiveness in load-bearing capacity and water resistance. The traditional method showed the lowest figures among the study results, placing it among the materials with the least leakage resistance.

  • Open Access

    Connection Between PVC Pipe and Concrete Manhole in Different Schemes

    by Haneen K. Ai-Oqaili, Hussein Al-Quraishi, Faaeza A. Abdulkareem

    Precast concrete manholes are essential in infrastructure management systems, allowing directional adjustments and connections in the sewerage system and serving as vital maintenance points. The connection between the concrete manhole and the PVC pipe is one of the most essential components of sewerage networks. In addition, quality bonding materials and Sealing provide substantial durability in harsh environmental conditions. However, external factors and internal corrosion result in connection failure, and sewage is released into the surrounding environment, leading to pollution. However, limited studies have been conducted about the connection between the pipe joint and the concrete manhole. Therefore, the study aims to find the most effective method connection by proposing three techniques with different materials. The test utilized a manhole concrete with a 44 cm diameter entrance connected to a 40 cm PVC pipe, advanced sealants based on polymers, epoxy, polyurethane, and modified cementitious materials. Fly ash was added at 25% of the cement weight to all cementitious materials employed in the paper. The Exfiltration test was carried out, and the water level was measured to test the resistance of the materials to leakage. The study indicated that the leakage ratio of the first method was 0.36% of the standard leakage test, providing it superior in leakage resistance. Additionally, the leakage ratio of the second method was 1.81% higher than the leakage test standard. In contrast, the third method showed a leakage ratio of 1% from the standard leakage test. The leakage ratio of the conventional method was 10.90% higher than the standard leakage test, making it the least effective among alternative methods. The results indicate that advanced leakage systems offer efficient and effective ways of closing the gap, improving the efficient and reliable connection between the manhole and the pipe, and enhancing the system’s ability to withstand environmental conditions. Consequently, diminishing the probability of leakage. Additionally, cement-based techniques showed potential effectiveness, provided that the internal composition of the material and the application method align with the requirements for leak resistance and structural durability.

  • Open Access

    Numerical Investigation for Selection the Optimal Flexural Strengthening Strategy of Reinforced Concrete Beams

    by Raad Abdulkhudhur, Murtadha Hardan Dawood, Hussein Al-Quraishi

    Reinforced concrete is the most widespread material that is used in structural applications. In structural systems, concrete beams can become damaged due to aging and increased design loads. Furthermore, for architectural purposes, specific dimensions may be imposed on concrete beams. For these reasons, it always needed to strengthen these beams. In this study, a numerical study was conducted to simulate the strengthening and improving of the flexural strength of reinforced concrete beams using three techniques: carbon fiber (CFRP sheets), steel plate, and external bars. The numerical analysis was verified with previous experimental studies. For the parametric study, the thickness, number of layers, and tensile strength were adopted for the CFRP strengthening technique. For the steel plates, the effect of changing the thickness and number of layers and yield stress was studied. Finally, for the additional external bars, different ratios of longitudinal reinforcement were investigated. After conducting numerical analysis of the studied models, the results showed a clear increase in the ultimate load and stiffness of the beams when strengthened with carbon fiber and steel plate, especially when increasing the tensile strength and yield strength, which was the most influential parameter, compared to a very limited effect of the number of layers due to the separation between the layers, especially for CFRP. However, both strategies showed brittle failure without clear ductility. Using additional external bars or increasing the ratio of longitudinal reinforcement was the most influential strengthening strategy in terms of increasing the beams’ capacity for bending and ductility.


  • Open Access

    Axial Compression Behavior of Concrete-Encased CFST Columns

    by Raad Abdulkhudhur, Mohammed Elwi, Hussein Al-Quraishi

    Composite construction known as concrete-encased CFST is an outer covering of concrete surrounding a steel tube filled with concrete. It is employed as a structural member in multi-story buildings, large structures, bridges, and underground subway systems. Most of the literature deals with steel tubes filled with core concrete or concrete-encased steel tubes filled with core concrete with main reinforcement, but in the present study, CFST is used as conventional reinforcement. Therefore, five concrete-encased CFST columns and one normal reinforced concrete column were loaded axially. Variables were effects of CFST, percentage of steel tubes, outer concrete compressive strength, compressive strength of steel tube concrete, and ratio of unfilled steel tubes. The experimental test result of the reference concrete-encased CFST ultimate axial compression strength showed 65.1% strength of a conventional column. An increase in the ratio of CFST from 6.8% to 10.2% enhanced ultimate axial compression by 19.2% compared to the reference concrete-encased CFST column. Furthermore, a rise in the outer compression strength of the outer concrete from 15 MPa to 20 MPa resulted in an increase of 14.94% in ultimate axially compression loads. An increase of concrete compression strength within the steel tubes from 35 MPa to 45 MPa resulted in a slight increase of 0.62% in the ultimate load. The 16.8% reduction in the ultimate load, however, was due to the presence of a hollow steel tube inside the concrete-filled CFST. The validated finite element model was therefore employed to examine the effect of different parameters that affect the concrete column using a parametric study.


  • Open Access

    Synergistic effect of nano-silica, steel slag, and waste glass on the microstructure, electrical resistivity, and strength of ultra-high-performance concrete

    by Abbas J. Mohammed, Maan S. Hassan, Hussein Al-Quraishi

    This study examined the microstructure characteristics, electrical resistivity (ER), and mechanical properties of ultra-high-performance concrete (UHPC) made with nano-silica (NS), electric arc furnace slag (EAFS), and waste glass powder (WGP). Eight concrete mixtures of binary and ternary blends were assessed to investigate the possible relationships between the observed physical and microstructural features with the obtained compressive and flexural strengths. The individual and combined effects of NS, EAFS (up to 50% replacement of silica sand), and WGP (up to 30% cement replacement) on the examined properties were evaluated. Scanning electron microscopy (SEM), thermogravimetric (TG) analysis, X-ray diffraction (XRD), ER, and pH values, and measurements were employed. SEM examination indicated that using NS along with EAFS and WGP reduced gap space around the fiber, and the enormous single cracks turned into numerous small cracks, thereby improving bonding and flexural strength. TG and XRD studies supported this finding. The ER for the EAFS specimens was enhanced without compromising the alkalinity range of concrete, as proved by pH tests, which address the possible corrosion problem of reinforcement. Thus, sustainable UHPC is achievable.


  • Numerical analysis of concrete-encased concrete filled steel tube columns

    by Raad Abdulkhudhur, Hussein Al-Quraishi, Mohammed Elwi

    The finite element method is a prevalent numerical methodology employed extensively in the field of engineering. The behavior of a concrete-encased, concrete- f The finite element method is a prevalent numerical methodology employed extensively in the field of engineering. The behavior of a concrete-encased, concrete- f


  • Numerical analysis of concrete-encased concrete filled steel tube beams

    by Raad Abdulkhudhur, Hussein Al-Quraishi, Mohammed Elwi

    One of the most commonly used numerical methods in engineering is the finite element method. To predict how concrete will behave, researchers studied its materi One of the most commonly used numerical methods in engineering is the finite element method. To predict how concrete will behave, researchers studied its materi


  • Reusing pulverized clay brick waste and pulverized burnt clay brick waste in concrete mixtures as a partial replacement for cement

    by Elaf Abdul Azal Ihsan, Hussein Al-Quraishi, Ayat Hussein Mahdi

    Replacement of the contents of concrete mixture with different types of solid waste is considered to be a good solution for sludge disposal. Replacement cement Replacement of the contents of concrete mixture with different types of solid waste is considered to be a good solution for sludge disposal. Replacement cement