DLDiva Lugassy

Diva Lugassy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Diva Lugassy has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Gil Ben-Izhack

    Dental Division, Shamir (Assaf Harofeh) Medical Center, Zerifin 70300, Israel

    7 shared publications
  • Asaf Shely

    Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel

    6 shared publications
  • Joseph Nissan

    Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel

    5 shared publications
  • Ofir Rosner

    Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel

    5 shared publications
  • Eran Zenziper

    Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel

    4 shared publications
  • Yoav Shapinko

    Department of Orthodontics, Faculty of Dentistry, Tel-Aviv University, Tel- Aviv, Israel

    3 shared publications

Latest Publications

  • Impact of conflict-induced stress on dental and skeletal development in children and adolescents

    by Diva Lugassy, Thabet Asbi, Isabelle Meinster, Jamil A. Shibli, Moshe Davidovitch, Nir Shpack, Doron Haim

    Objectives: To investigate the impact of living in a war zone on acceleration of skeletal maturation and development of permanent teeth. Materials and Methods: A total of 272 Israeli children and adolescents aged 9–15 years participated in this study. The Gaza group included 106 participants from the Gaza envelope area (within 7 km of the Gaza Strip border), while the central group consisted of 166 participants from central Israel. Skeletal maturation and dental development were assessed using lateral cephalometric and panoramic radiographs, respectively. Results: Significant differences were observed in all maturation variables, including skeletal maturation as well as maturation of the upper and lower second molars (right and left) and upper canines. The Gaza envelope group exhibited more advanced and accelerated maturation than the central group ( P < .0005). Positive correlations were identified among tooth maturation, chronological age, and skeletal development (0.519 < r < 0.599). Linear regression analysis revealed that the maturation of the lower left second molar accounted for 47.8% of variance in skeletal maturation. Conclusions: In this study, we confirm that children living under the stress of a conflict zone exhibited earlier skeletal maturation and accelerated eruption of permanent second molars and upper canines than their peers. The early eruption of second molars and canines, particularly the lower left second molar, may serve as a predictive marker for pubertal progression.


  • Open Access

    Stage of manual skill acquisition with Simodont virtual reality simulator for pre-clinical dental training: an interventional matching study

    by Uziel Jeffet, Nir Uziel, Noga Retzkin Binyamin, Ido Vana, Noa Sadan, Yoav Shapinko, Shifra Levartovsky, Tamar Brosh, Diva Lugassy

    Recent studies have demonstrated the effectiveness of virtual reality (VR) simulators in dental education. However, these studies primarily focused on the

  • Open Access

    Stage of manual skill acquisition with Simodont virtual reality simulator for pre-clinical dental training: An interventional matching study

    by Uziel Jeffet, Nir Uziel, Noga Retzkin Binyamin, Ido Vana, Noa Sadan, Yoav Shapinko, Shifra Levartovsky, Tamar Brosh, Diva Lugassy

    Background Recent studies have demonstrated the effectiveness of virtual reality (VR) simulators in dental education. However, these studies primarily focused on the early stages of psychomotor skill acquisition and often did not account for confounding variables when assigning participants to study groups. The present study aims to determine the stage of manual skill acquisition at which VR simulator training is most effective, using a matched interventional study design. Methods A planned crossover study with a matched design was conducted among 70 undergraduate dental students from Tel Aviv University. Matching was performed based on age, gender, dominant hand, spatial perception, and fine motor skills. To evaluate manual performance under both direct vision (Class I cavity preparation) and indirect vision (Class 1 occlusal-proximal [OP] preparation), students were evenly assigned to two groups (Group 1 and Group 2), matched to control for potential confounding factors. Using a crossover approach, each group alternated roles as the experimental or control group for the two phantom-based tasks. The experimental group trained with both the Simodont virtual reality simulator and the conventional phantom simulator, while the control group practiced solely with the conventional simulator on plastic teeth. The experimental group was further subdivided into three subgroups based on the timing of Simodont exposure corresponding to different stages of skill acquisition: cognitive, associative, and autonomous. Results No statistically significant differences were observed between the experimental and control groups in manual performance scores under direct vision (p = 0.461) or indirect vision (p = 0.916). Additionally, no significant differences were found among the three experimental subgroups representing different stages of skill acquisition (p > 0.05). Conclusion The integration of the Simodont simulator during the preclinical year does not appear to enhance dental students’ manual performance under either direct or indirect vision conditions.

  • Open Access

    Analysis of stress, anxiety, and depression among dental students and dentists: a cross-sectional questionnaire-based survey

    by Diva Lugassy, Sarit Naishlos, Yoav Shapinko, Sara Zissu, Rotem Shitrit Lahav, Asaf Shely, Gil Ben-Izhack

    Dental education is considered a highly stressful training process that can lead to high levels of stress, anxiety and depression, which can affect wellbeing and performance. Moreover, after the completion of training, working as a dentist is a stressful occupation due to direct interactions with patients and the necessity of carrying out complicated dental procedures in the vulnerable area of the patient’s mouth. Therefore, the aim of this study was to evaluate stress, anxiety, and depression levels experienced by dental students compared to those among dentists. A cross-sectional survey was carried out involving 42 general dentists (graduates of Tel-Aviv University) and 73 dental students in their clinical years (fifth and sixth years at Tel-Aviv University). Psychological wellbeing was assessed using the Depression Anxiety Stress Scale (DASS-21), which measures the severity of psychological distress via a reliable self-rating questionnaire. The overall prevalence of depression, anxiety, and stress among dental students was 54.79%, 58.9%, and 57.53%, respectively, and the overall prevalence of depression, anxiety, and stress among dentists was 23.8%, 21.5%, and 21.4%, respectively. Significant differences were found in relation to DASS categories (normal, mild, moderate, severe, and extremely severe) for depression (p = 0.005), anxiety (p = 0.003), and stress (p = 0.002), with higher levels of psychological symptoms of anxiety, stress, and depression observed in clinical dental students and lower levels observed in dentists. No significant differences were found between male and female participants regarding mean DASS scores for depression, anxiety, and stress across all study groups (p > 0.208). High levels of depression, anxiety, and stress were observed in clinical dental students. However, these levels significantly decreased upon becoming a dentist. No differences were found regarding gender among the two groups. However, a longitudinal study following dental students during the process of dental education and into their work life is required.


  • Open Access

    Three Self-Adhesive Resin Cements and Their Influence on the Marginal Adaptation of Zirconia-Reinforced Lithium Silicate Single Crowns: An In Vitro Scanning Electron Microscope Evaluation

    by Asaf Shely, Joseph Nissan, Diva Lugassy, Ofir Rosner, Eran Zenziper, Tharaa Egbaria, Gil Ben-Izhack

    Background: In everyday dentistry, monolithic single crowns can be cemented with self-adhesive resin cements. The aim of this in vitro study was to evaluate how the marginal adaptation of full monolithic zirconia-reinforced lithium silicate (ZLS) single crowns is influenced by three different self-adhesive resin cements. Methods: Forty-five typodont teeth fully prepared for full monolithic crowns were divided into three groups (fifteen each) for the use of three different self-adhesive resin cements. A fourth control group (Temp-bond) was created by taking five teeth from each group before cementation with self-adhesive resin cements. All forty-five abutments were scanned using a Primescan intra-oral scanner (IOS), followed by computer-aided design (CAD) and computer-aided manufacturing (CAM) of zirconia-reinforced lithium silicate (ZLS) full crowns using a four-axis machine. Initially, the crowns of the control group were fixed to the abutments using Temp-bond, and the marginal gap was evaluated using a scanning electron microscope (SEM). After removing the control group crowns from the abutments, fifteen crowns in each group were cemented using a different self-adhesive resin cement and observed under SEM for evaluation of the marginal gap. A Kolmogorov–Smirnov test was performed, indicating no normal distribution (p < 0.05), followed by Mann–Whitney tests (α = 0.05). Results: The total mean marginal gap of the temp-bond control group was significantly lower compared to all three groups of self-adhesive resin cement (p < 0.0005). The total mean marginal gap of the G-cem ONE group was significantly lower compared to the TheraCem group (p < 0.026) and RelyX U200 group (p < 0.008). The total mean marginal gap of the TheraCem group was significantly higher than the G-cem ONE group (p < 0.026) but showed no significant difference with the RelyX U200 group (p > 0.110). Conclusions: All four groups showed a clinically acceptable marginal gap (<120 microns). Although all three groups of self-adhesive resin cement showed a significant increase in the marginal gap compared to the temp-bond control group, they were within the limits of clinical acceptability. Regarding the marginal gap, in everyday dentistry, it is acceptable to use all three self-adhesive resin cements, although the G-cem ONE group exhibited the lowest marginal gap for ZLS single crowns.


  • Open Access

    The Impact of Open versus Closed Computer-Aided Design/Computer-Aided Manufacturing Systems on the Marginal Gap of Zirconia-Reinforced Lithium Silicate Single Crowns Evaluated by Scanning Electron Microscopy: A Comparative In Vitro Study

    by Asaf Shely, Joseph Nissan, Ofir Rosner, Eran Zenziper, Diva Lugassy, Khadija Abidulkrem, Gil Ben-Izhack

    This study aimed to compare the impact of CAD/CAM closed systems and open systems on the marginal gap of monolithic zirconia-reinforced lithium silicate (ZLS) ceramic crowns, as both systems are used in everyday dentistry, both chair-side and laboratory. For the closed system, 20 plastic teeth were scanned by a Primescan intra-oral scanner (IOS), and for the open system, the same number of plastic teeth were scanned by Trios 4 IOS. For the closed system, CEREC software was used, and for the open system, EXOCAD software was used. All 40 ZLS crowns were grinded by the same four-axis machine and cemented with Temp-bond, followed by self-adhesive resin cement. For each type of cement, an evaluation of the marginal gap was conducted by scanning electron microscopy (SEM). Before comparisons between the groups, a Kolmogorov–Smirnov test was performed on the study variables showing a normal distribution (p > 0.05). Independent T tests (α = 0.05) and paired-sample T tests (α = 0.05) were used. The independent T test found no significant mean marginal gap differences in the zirconia-reinforced lithium silicate crowns bonded with Temp-bond and scanned by Primescan (28.09 μm ± 3.06) compared to Trios 4 (28.94 μm ± 3.30) (p = 0.401), and there was no significant mean marginal gap differences in zirconia-reinforced lithium silicate crowns bonded with self-adhesive resin cement (Gcem ONE) and scanned by Primescan (46.70 μm ± 3.80) compared to Trios 4 (47.79 μm ± 2.59) (p = 0.295). Paired-sample T tests showed significantly higher mean marginal gaps with Gcem ONE compared to Temp-bond for the total mean marginal gap when scanning with Primescan (p = 0.0005) or Trios 4 (p = 0.0005). In everyday dentistry, both closed systems (Primescan with Cerec) and open systems (Trios 4 with Exocad) can be used to achieve an acceptable (® DUO single crowns. There is a significant difference between cementation with Temp-bond and Gcem ONE self-adhesive resin cement (p < 0.05).


  • Open Access

    Comparison between Conventional and Digital Impressions for Determining Axes and Distances of Three Implants in Straight and Curved Lines: An In Vitro Study

    by Gil Ben-Izhack, Ophir Rosner, Eran Zenziper, Joseph Nissan, Reema Hosary, Diva Lugassy, Asaf Shely

    Background: In this study, we aimed to compare the effects of conventional and digital impressions on several parameters (inter-implant distance, intra-implant distance, inter-implant axis, and intra-implant axis) of three implants in curved lines and straight lines by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS). Methods: Two 3D models were fabricated using a printer, each model with three internal hex implants analogues at the positions of 15#,16#,17# (straight line) and 12#,13#,14# (curved line). Standard intra-oral scan bodies (ISBs) were used, and the two models were scanned using 7 Series dental wings (LBS, reference model), followed by ten scans with Primescan (digital method). Standard Tessellation Language (STL) files were created. Five polyether impressions were taken from each model (straight and curved), and gypsum type 4 models were poured; each model was scanned five times to create a total of 25 STL files for each group (conventional method). The comparison between all the STL files (conventional and digital) was made by superimposition of the STL files on the STL reference model laboratory file using a 3D analyzing software. A Kolmogorov–Smirnov test was performed, followed by Mann–Whitney tests and Wilcoxon signed-rank tests. (p < 0.05). Results: For the conventional method, the mean errors were significantly higher for the curved line model (12–14) compared to the straight line model (15–17) for most parameters (p < 0.05). For the digital method, the mean errors were significantly higher for the curved-line model (12–14) compared to the straight line model (15–17) in half of the parameters (p < 0.05). Within the curved line model (12–14) and the straight line model (15–17), the mean errors between the conventional method and the digital method were not significant for most variables. Conclusions: The difference between curved lines and straight lines has an impact on the mean error of the conventional method. Both methods are reliable for straight and curved lines in partially dentate situations.


  • Open Access

    SEM Evaluation of the Marginal Gap of Zirconia-Reinforced Lithium Silicate Full Crowns and the Effect of Post Crystallization: An In Vitro Study

    by Asaf Shely, Diva Lugassy, Maxim Anufriev, Joseph Nissan, Olisya Rauchwerger, Gil Ben-Izhack

    Background: This study compared the influence of crystallization on marginal gap adaptation by using computer-aided design and manufacturing (CAD-CAM) for producing monolithic zirconia-reinforced lithium silicate (ZLS) ceramic crowns. Methods: A total of 25 plastic teeth were scanned using a Primescan intra-oral scanner (IOS), and ZLS crowns were ground. For each unit (abutment and crown), the marginal gap was evaluated pre crystallization and post crystallization at four regions of interest through the use of a scanning electron microscope (SEM). To compare the marginal gap between the two groups, a Kolmogorov–Smirnov test performed on the study variables indicated a normal distribution (p > 0.05) followed by paired samples T-tests (α = 0.0005). Results: After crystallization, there were significantly higher circumferential marginal gaps (CMGs) for all four surfaces (distal (p = 0.0005), mesial (p = 0.0005), palatal (p = 0.0005), and buccal (p = 0.0005)). The total mean marginal gap (MMG) revealed a significantly higher result for the post-crystallization group (79.82 ± 7.86 μm) compared to the pre-crystallization group (24.25 ± 5.49 μm). Conclusions: The post-crystallization group showed a significantly higher marginal gap compared to the pre-crystallization group in all parameters, but both groups were in the clinically accepted threshold (® DUO crowns and achieve better mechanical properties but significantly increase the marginal gap.


  • Open Access

    The Influence of Laboratory Scanner versus Intra-Oral Scanner on Determining Axes and Distances between Three Implants in a Straight Line by Using Two Different Intraoral Scan Bodies: A Pilot In Vitro Study

    by Asaf Shely, Diva Lugassy, Ophir Rosner, Eran Zanziper, Joseph Nissan, Shir Rachmiel, Yara Khoury, Gil Ben-Izhack

    Background: The purpose of this in vitro study was to compare the inter-implant distance, inter-implant axis, and intra-implant axis of three implants in a straight line by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS) with two different intra-oral scan bodies (ISBs). Methods: A 3D model was printed with internal hex implant analogs of three implants in positions 15#, 16#, and 17#. Two standard intra-oral scan bodies (ISBs) were used: MIS ISB (two-piece titanium) and Zirkonzhan ISB (two-piece titanium). Both ISBs were scanned using 7 Series dental wings (LBS) and 30 times using Primescan (IOS). For each scan, a stereolithography (STL) file was created and a comparison between all the scans was performed through superimposition of the STL files by using 3D analysis software (PolyWorks® 2020; InnovMetric, Québec, QC, Canada). A Kolmogorov–Smirnov test was performed followed by a Mann–Whitney test (p < 0.05). Results: The change in inter-implant distance for the MIS ISB was significantly lower compared to the ZZ (p < 0.05). The change in intra-implant angle was significantly lower for the ZZ ISB compared to MIS (p < 0.05). The changes in inter-implant angle between the mesial and middle and between the middle and distal were significantly lower for MIS compared to ZZ in contrast to mesial to distal, which was significantly higher (p < 0.05). Conclusions: Both ISBs showed differences in all the parameters between the LBS and the IOS. The geometry of the scan abutment had an impact on the inter-implant distance as the changes in the inter-implant distance were significantly lower for the MIS ISB. The changes in the intra-implant angle were significantly lower for the ZZ ISB. There is a need for further research examining the influence of geometry, material, and scan abutment parts on the trueness.


  • Turbine effect on dental students’ lateral pinch modulation and performances

    by D Lugassy, M Khalaily, A Shely, Y Levanon, S Portnoy, T Brosh

    Dental turbines can generate significant vibrations that may be transmitted to dentists’ hands. The vibrations contribute to neural impairment and decrease dexterity over the long duration. It is unclear whether such vibration effects would be detected in the short time during the pre-clinical year of dentistry study. To investigate the effect of vibrations on lateral pinch modulation and manual performance of dentistry students. Four lateral pinch modulation tests by a square-shaped force sensing resistor (FSR) were administered to 30 dental students during their phantom course. Tests were performed with dominant and non-dominant hands at two time points: T0 (2 months after commencing phantom training) and T1 (end of phantom training). At each time point, students accomplished two manual performance tests on plastic teeth. Comparisons were made between lateral pinch modulation test scores at different times, considering the differences between hands and gender. The relationships between the FSR tests and manual performance were also determined. The participating 19 female and 11 male students had a combined 50% response rate. At T1, the lateral pinch modulation for all tests significantly decreased for the dominant hand (P < 0.05) and non-dominant hand (P < 0.05). For the non-dominant hand at T1, the lateral pinch modulation of females significantly decreased as compared to males (P < 0.05). No significant correlations were found between lateral pinch modulation and manual tasks at T0 and T1. The lateral pinch modulation of the fingers of dental students deteriorated after only 8 months of training at phantom (short-time exposure), with females at higher risk and possibly earlier symptoms manifestation.