DPDeepu Jacob Punnoose

Deepu Jacob Punnoose

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Deepu Jacob Punnoose has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Peroneus Longus Tendon Autografts have Better Graft Diameter, Less Morbidity, and Enhanced Muscle Recuperation than Hamstring Tendon in ACL Reconstruction

    by Deepu Jacob Punnoose, Jacob Varghese, Bipin Theruvil, Appu Benny Thomas

    Background Recently the peroneus longus tendon (PLT) gained popularity in anterior cruciate ligament (ACL) reconstruction and has been utilized with satisfactory outcomes. However, there are concerns regarding donor site morbidity. This study aims to compare the functional outcome of ACL reconstruction using hamstring (HT) and PLT autografts and evaluate the donor site morbidity. Methods Patients who underwent ACL reconstruction were allocated to two groups (HT and PLT). Graft diameter was measured intraoperatively. Knee functional outcome was evaluated with IKDC and Tegner-Lysholm scores preoperatively, and postoperatively after 3 months, 6 months, and 1 year. Donor site morbidities were assessed with thigh circumference measurements, subjective evaluation of sensory disturbances, and ankle scoring with AOFAS and FADI scores. Results At 1-year follow-up, the PLT group showed comparable IKDC (p = 0.925) and Tegner-Lysholm (p = 0.600) scores with those of the HT group. The mean graft diameter in the PLT group (7.93 ± 0.52 mm) was larger compared with the HT group (7.43 ± 0.50 mm) (p < 0.001). The incidence of thigh atrophy (HT-16.7%, PLT-10%) and sensory disturbances (HT-73.3%, PLT-10%) was greater in the HT group. There was no significant ankle donor site morbidity in the PLT group (AOFAS-98.67 ± 3.45, FADI-99.23 ± 1.69). Conclusion ACL reconstruction with PLT had comparable functional outcome with that of HT at 1 year. However, PLT demonstrated larger graft diameter, less donor site morbidity, and enhanced muscle recovery without significantly affecting the ankle function. PLT can be safely used as an acceptable alternative graft choice harvested from outside the knee for ACL reconstruction.


  • “External Iliac Artery Injury After Total Hip Arthroplasty in an Infected Intrapelvic Hemiarthroplasty”

    by Deepu Jacob Punnoose, Paul George, Abhijeet Wakure, Julio C. Kandathil, Bipin Theruvil

    Case: We report a patient with intrapelvic prosthetic protrusion associated with infection after hemiarthroplasty for a fracture neck of the femur. We discuss the challenges involved in the management of this complex case with recommendations to manage a vascular injury. Conclusion: In patients with an intrapelvic prosthesis, thorough preoperative vascular evaluation and vigilant postoperative check are required to prevent a vascular injury. In a suspected vessel injury after primary or revision total hip arthroplasty, it is imperative to get proximal control of the vessel before re-exploration. A combined arterial Doppler and computerized tomography angiogram is more reliable in picking up arterial impingement by acetabular screws.


  • Total Hip Arthroplasty in Post-traumatic Acetabular Nonunion with Symphysis Pubis Diastasis

    by Deepu Jacob Punnoose, Nizaj N, Sukesh A N, Julio C. Kandathil, Bipin Theruvil

    Case: We report a patient with a long-standing post-traumatic pubic diastasis along with acetabular nonunion who developed painful hip arthritis that needed a total hip arthroplasty. We discuss the unique challenges in the acetabular component positioning. Conclusion: In patients with symphysis pubis diastasis, the surgeon should be prepared to place the cup in less than normal anteversion. This relative retroversion, which is an unusual position, is due to the external rotation of the whole hemipelvis including the femur. The degree of version of the cup should be guided by intraoperative stability checks and to ensure an impingement free range of motion.