Deepu Jacob Punnoose
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Deepu Jacob Punnoose has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Bipin Theruvil
Department of Orthopaedics, VPS Lakeshore Hospital, Kochi, India
3 shared publications - Julio Chacko Kandathil
Department of Radiology, VPS Lakeshore Hospital, Kochi, India
2 shared publications - Abhijeet Wakure
Deparment of Plastic Surgery, VPS Lakeshore Hospital, Kochi, India
1 shared publication - Appu Benny Thomas
Department of Orthopaedics, VPS Lakeshore Hospital, Kochi, India
1 shared publication - Jacob Varughese
Senior Consultant and HOD, Director of Orthopedics and Department of Joint Replacement & Sports Medicine, VPS Lakeshore Hospital, Kochi, India
1 shared publication - Nizaj Nasimudeen
Department of Orthopaedics, Apollo Adlux Hospital, Cochin, Kerala, India
1 shared publication
Latest Publications
- 23 May 2024
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 58 (7) , 979-986
Peroneus Longus Tendon Autografts have Better Graft Diameter, Less Morbidity, and Enhanced Muscle Recuperation than Hamstring Tendon in ACL Reconstruction
Background Recently the peroneus longus tendon (PLT) gained popularity in anterior cruciate ligament (ACL) reconstruction and has been utilized with satisfactory outcomes. However, there are concerns regarding donor site morbidity. This study aims to compare the functional outcome of ACL reconstruction using hamstring (HT) and PLT autografts and evaluate the donor site morbidity. Methods Patients who underwent ACL reconstruction were allocated to two groups (HT and PLT). Graft diameter was measured intraoperatively. Knee functional outcome was evaluated with IKDC and Tegner-Lysholm scores preoperatively, and postoperatively after 3 months, 6 months, and 1 year. Donor site morbidities were assessed with thigh circumference measurements, subjective evaluation of sensory disturbances, and ankle scoring with AOFAS and FADI scores. Results At 1-year follow-up, the PLT group showed comparable IKDC (p = 0.925) and Tegner-Lysholm (p = 0.600) scores with those of the HT group. The mean graft diameter in the PLT group (7.93 ± 0.52 mm) was larger compared with the HT group (7.43 ± 0.50 mm) (p < 0.001). The incidence of thigh atrophy (HT-16.7%, PLT-10%) and sensory disturbances (HT-73.3%, PLT-10%) was greater in the HT group. There was no significant ankle donor site morbidity in the PLT group (AOFAS-98.67 ± 3.45, FADI-99.23 ± 1.69). Conclusion ACL reconstruction with PLT had comparable functional outcome with that of HT at 1 year. However, PLT demonstrated larger graft diameter, less donor site morbidity, and enhanced muscle recovery without significantly affecting the ankle function. PLT can be safely used as an acceptable alternative graft choice harvested from outside the knee for ACL reconstruction.
- 23 May 2024
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 58 (7) , 979-986
Peroneus Longus Tendon Autografts have Better Graft Diameter, Less Morbidity, and Enhanced Muscle Recuperation than Hamstring Tendon in ACL Reconstruction
Background Recently the peroneus longus tendon (PLT) gained popularity in anterior cruciate ligament (ACL) reconstruction and has been utilized with satisfactory outcomes. However, there are concerns regarding donor site morbidity. This study aims to compare the functional outcome of ACL reconstruction using hamstring (HT) and PLT autografts and evaluate the donor site morbidity. Methods Patients who underwent ACL reconstruction were allocated to two groups (HT and PLT). Graft diameter was measured intraoperatively. Knee functional outcome was evaluated with IKDC and Tegner-Lysholm scores preoperatively, and postoperatively after 3 months, 6 months, and 1 year. Donor site morbidities were assessed with thigh circumference measurements, subjective evaluation of sensory disturbances, and ankle scoring with AOFAS and FADI scores. Results At 1-year follow-up, the PLT group showed comparable IKDC (p = 0.925) and Tegner-Lysholm (p = 0.600) scores with those of the HT group. The mean graft diameter in the PLT group (7.93 ± 0.52 mm) was larger compared with the HT group (7.43 ± 0.50 mm) (p < 0.001). The incidence of thigh atrophy (HT-16.7%, PLT-10%) and sensory disturbances (HT-73.3%, PLT-10%) was greater in the HT group. There was no significant ankle donor site morbidity in the PLT group (AOFAS-98.67 ± 3.45, FADI-99.23 ± 1.69). Conclusion ACL reconstruction with PLT had comparable functional outcome with that of HT at 1 year. However, PLT demonstrated larger graft diameter, less donor site morbidity, and enhanced muscle recovery without significantly affecting the ankle function. PLT can be safely used as an acceptable alternative graft choice harvested from outside the knee for ACL reconstruction.
- 1 July 2023
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 13 (3)
“External Iliac Artery Injury After Total Hip Arthroplasty in an Infected Intrapelvic Hemiarthroplasty”
Case: We report a patient with intrapelvic prosthetic protrusion associated with infection after hemiarthroplasty for a fracture neck of the femur. We discuss the challenges involved in the management of this complex case with recommendations to manage a vascular injury. Conclusion: In patients with an intrapelvic prosthesis, thorough preoperative vascular evaluation and vigilant postoperative check are required to prevent a vascular injury. In a suspected vessel injury after primary or revision total hip arthroplasty, it is imperative to get proximal control of the vessel before re-exploration. A combined arterial Doppler and computerized tomography angiogram is more reliable in picking up arterial impingement by acetabular screws.
- 1 July 2023
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 13 (3)
“External Iliac Artery Injury After Total Hip Arthroplasty in an Infected Intrapelvic Hemiarthroplasty”
Case: We report a patient with intrapelvic prosthetic protrusion associated with infection after hemiarthroplasty for a fracture neck of the femur. We discuss the challenges involved in the management of this complex case with recommendations to manage a vascular injury. Conclusion: In patients with an intrapelvic prosthesis, thorough preoperative vascular evaluation and vigilant postoperative check are required to prevent a vascular injury. In a suspected vessel injury after primary or revision total hip arthroplasty, it is imperative to get proximal control of the vessel before re-exploration. A combined arterial Doppler and computerized tomography angiogram is more reliable in picking up arterial impingement by acetabular screws.
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 11 (3)
Total Hip Arthroplasty in Post-traumatic Acetabular Nonunion with Symphysis Pubis Diastasis
Case: We report a patient with a long-standing post-traumatic pubic diastasis along with acetabular nonunion who developed painful hip arthritis that needed a total hip arthroplasty. We discuss the unique challenges in the acetabular component positioning. Conclusion: In patients with symphysis pubis diastasis, the surgeon should be prepared to place the cup in less than normal anteversion. This relative retroversion, which is an unusual position, is due to the external rotation of the whole hemipelvis including the femur. The degree of version of the cup should be guided by intraoperative stability checks and to ensure an impingement free range of motion.
- 1 July 2021
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 11 (3)
Total Hip Arthroplasty in Post-traumatic Acetabular Nonunion with Symphysis Pubis Diastasis
Case: We report a patient with a long-standing post-traumatic pubic diastasis along with acetabular nonunion who developed painful hip arthritis that needed a total hip arthroplasty. We discuss the unique challenges in the acetabular component positioning. Conclusion: In patients with symphysis pubis diastasis, the surgeon should be prepared to place the cup in less than normal anteversion. This relative retroversion, which is an unusual position, is due to the external rotation of the whole hemipelvis including the femur. The degree of version of the cup should be guided by intraoperative stability checks and to ensure an impingement free range of motion.