  • Experimental Investigations on IEC Suggested Methods for Improving Waveshape During Impulse Voltage Testing

    by B. Karthikeyan, R. Rajesh, M. Balasubramanian, S. Saravanan

    The objective of lightning impulse voltage (LI Voltage) test on power transformer is to check the dielectric strength of the transformer against over voltages of atmospheric origin. Mostly when transformers of high transformation ratio is subjected to LI voltage test, the standard LI voltage waveshape distorts and consequently the wavetail falls much below the specified tolerance and swings to opposite polarity. In these cases, IEC has suggested some waveshape improvement techniques in the test circuit or energy enhancement of the impulse generator. This paper elucidates the experimental investigations carried out on a 315 kVA, 11 kV/433 V, Dyn 11, three phase transformer. Investigations was carried out based on the voltage and stress analysis on the transformer windings. For this analysis, tapping are provided on one of the HV winding at 100%, 87.5%, 62.5%, 37.5%, and 12.5%. The investigations include voltage and stress distribution on the windings, voltage across the waveshape component and analysis of stress across major and minor insulation. Apart from voltage and stress distribution analysis, a few novel techniques of waveshape improvement are attempted and a comparative analysis with IEC methods is also presented in this paper


  • Efficacy Of Back Propagation Neural Network Based On Various Statistical Measures For Pd Pattern Classification Task

    by B. Karthikeyan, S. Gopal, P.S. Srinivasan, S. Venkatesh

    Partial Discharge is the breakdown confined to the localized regions of the insulating medium. The analysis and classification of Partial Discharge based on its site of occurrence is a complex process notwithstanding the intricacies involved in the digital computer acquisition system, since partial discharge is inherently a stochastic and a non-Markovian process in which there can be significant statistical variability. Since each defect has a particular deterioration mechanism, it is imperative to discern the correlation between the discharge patterns and the nature of defect in order to ascertain the quality of insulation. Neural Network which is a non-parametric method has been a recent innovative technique suitable for partial discharge pattern classification. The Back Propagation Algorithm Neural Network is verified and validated for the various inputs based on established validation techniques. As against the conventional technique of using mathematical descriptors adopted by previous researchers, unique characteristic input feature vectors have been devised in this work in order to provide a possible solution to a simple yet an effective preprocessing methodology. The efficacy of the classification of the standard partial discharge defect sources has been evaluated and analyzed