PAP. Agoris

P. Agoris

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


P. Agoris has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • J. J. Smit

    Member, IEEE, Delft University of Technology, Delft, 2628CD, The Netherlands

    2 shared publications
  • J.J. Smit

    Delft University of Technology, High-voltage Technology and Management, PO Box 5031, 2600 GA Delft, The Netherlands

    2 shared publications
  • S. Meijer

    Delft University of Technology, High-voltage Technology and Management, PO Box 5031, 2600 GA Delft, The Netherlands

    2 shared publications
  • S. Meijer

    Delft University of Technology, Delft, 2628CD, The Netherlands

    2 shared publications
  • E. Gulski

    Delft University of Technology, High-voltage Technology and Management, PO Box 5031, 2600 GA Delft, The Netherlands

    1 shared publication
  • J. Lopez-Roldan

    Pauwels Energy Group, PO Box B-2800 Mechelen, Belgium

    1 shared publication

Latest Publications

  • Building a Transformer Defects Database for UHF Partial Discharge Diagnostics

    by P. Agoris, P. Cichecki, S. Meijer, J. J. Smit

    In the case of a defective transformer, when a partial discharge is detected and recorded, critical information can be deduced from its pattern, such as the type of defect, its criticality or even information on the level of degradation of the insulation. This information can help to determine the remaining life of the transformer and thus provide criteria for its maintenance and operation. In this paper different artificial PD patterns will be recorded in the laboratory, representative of specific transformer defects, in order to build a database for comparison purposes when measuring on-line. This can greatly improve the recognition and identification of the defect and thus help take some important life assessment conclusions on the transformer.

  • Sensitivity Check of an Internal VHF/UHF Sensor for Transformer Partial Discharge Measurements

    by P. Agoris, S. Meijer, J. J. Smit

    The failure of a transformer can result in high costs due to repair (or replacement) and outage costs. Failures in a power transformer are mostly due to defects in the insulation. Therefore, transformers should be regularly monitored for insulation defects by PD measurements. The UHF technique (and in general on-line PD measurement techniques) could play an important part in insulation condition assessment, since it is not so cost demanding (especially compared to DGA), it can be performed on-line and can localize and identify the defect with minimum noise interference. However, the UHF technique requires dielectric windows fitted on the tank of the transformer, in order to place the sensors, and especially old transformers do not incorporate these on the tank, by design. Therefore another way of measuring in the UHF range should be implemented. In this paper a new internal sensor will be presented which can be installed through the oil-drain valve of the transformer and its sensitivity and application will be tested.


  • Sensitivity Check of Internal Sensor for Power Transformer Partial Discharge Measurements

    by P.D. Agoris, S. Meijer, J.J. Smit, J. Lopez-Roldan

    The UHF partial discharge measurement technique is under research in order to be used for the detection, identification and localization of discharging defects within a power transformer. However, it requires installed dielectric windows on the transformer tank for the placement of the UHF sensors, a feature not available in all transformers especially old ones that have a higher risk of failure. Therefore, it is necessary to develop UHF sensors that can be used in the case of transformers without dielectric windows. In this paper such a sensor in its early design stages is studied, which can be inserted in a transformer from one of its valves


  • Sensitivity check for on-line VHF/UHF PD detection on Transmission cables

    by P.D. Agoris, S. Meijer, E. Gulski, J.J. Smit, T.J.W. Hermans, L. Lamballais

    The VHF/UHF PD detection technique is a non-intrusive method for power cable PD diagnostics. It incorporates a VHF/UHF current probe placed at the grounding of the cable and a spectrum analyzer connected to the probe. This technique however is very difficult to calibrate due to different factors affecting the frequency response of the measuring setup. In this paper the calibration procedure is described and discussed. Furthermore two examples of on-site calibration are presented, before the actual PD measurements take place. In these examples the sensitivity of the technique is also studied