Building a Transformer Defects Database for UHF Partial Discharge Diagnostics
In the case of a defective transformer, when a partial discharge is detected and recorded, critical information can be deduced from its pattern, such as the type of defect, its criticality or even information on the level of degradation of the insulation. This information can help to determine the remaining life of the transformer and thus provide criteria for its maintenance and operation. In this paper different artificial PD patterns will be recorded in the laboratory, representative of specific transformer defects, in order to build a database for comparison purposes when measuring on-line. This can greatly improve the recognition and identification of the defect and thus help take some important life assessment conclusions on the transformer.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2070-2075
Building a Transformer Defects Database for UHF Partial Discharge Diagnostics
In the case of a defective transformer, when a partial discharge is detected and recorded, critical information can be deduced from its pattern, such as the type of defect, its criticality or even information on the level of degradation of the insulation. This information can help to determine the remaining life of the transformer and thus provide criteria for its maintenance and operation. In this paper different artificial PD patterns will be recorded in the laboratory, representative of specific transformer defects, in order to build a database for comparison purposes when measuring on-line. This can greatly improve the recognition and identification of the defect and thus help take some important life assessment conclusions on the transformer.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2065-2069
Sensitivity Check of an Internal VHF/UHF Sensor for Transformer Partial Discharge Measurements
The failure of a transformer can result in high costs due to repair (or replacement) and outage costs. Failures in a power transformer are mostly due to defects in the insulation. Therefore, transformers should be regularly monitored for insulation defects by PD measurements. The UHF technique (and in general on-line PD measurement techniques) could play an important part in insulation condition assessment, since it is not so cost demanding (especially compared to DGA), it can be performed on-line and can localize and identify the defect with minimum noise interference. However, the UHF technique requires dielectric windows fitted on the tank of the transformer, in order to place the sensors, and especially old transformers do not incorporate these on the tank, by design. Therefore another way of measuring in the UHF range should be implemented. In this paper a new internal sensor will be presented which can be installed through the oil-drain valve of the transformer and its sensitivity and application will be tested.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2065-2069
Sensitivity Check of an Internal VHF/UHF Sensor for Transformer Partial Discharge Measurements
The failure of a transformer can result in high costs due to repair (or replacement) and outage costs. Failures in a power transformer are mostly due to defects in the insulation. Therefore, transformers should be regularly monitored for insulation defects by PD measurements. The UHF technique (and in general on-line PD measurement techniques) could play an important part in insulation condition assessment, since it is not so cost demanding (especially compared to DGA), it can be performed on-line and can localize and identify the defect with minimum noise interference. However, the UHF technique requires dielectric windows fitted on the tank of the transformer, in order to place the sensors, and especially old transformers do not incorporate these on the tank, by design. Therefore another way of measuring in the UHF range should be implemented. In this paper a new internal sensor will be presented which can be installed through the oil-drain valve of the transformer and its sensitivity and application will be tested.