Senior Member, IEEE, Bonneville Power Administration, PO Box 491, Vancouver, WA 98666 USA; Principal Engineer, Bonneville Power Administration; Member, Power System Relay Committee, Relay Communications Sub-committee; Chair, Synchrophasor Standard working group; Registered Professional Engineer, Washington State
2 shared publications - Anthony Faris
Bonneville Power Administration, 17201 Portland, Oregon United States
1 shared publication - Zhenyu Huang
Pacific Northwest National Laboratory
1 shared publication
Latest Publications
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-6
PMU Testing and Installation Considerations at the Bonneville Power Administration
BPA has a real-time phasor measurement system with more than 22 PMUs installed in substations feeding data to a control center. To assure the quality and accuracy of the measurement, BPA has developed an extensive test plan for PMUs. From simple beginnings of basic tests, these procedures have continually evolved with both the variety of PMU equipment and applications for which the data was used. Current test methods under development are aimed for more comprehensive characterization of PMU measurement and test process simplification. Basic test procedures assure steady state accuracy of magnitude, phase, and frequency measurement. Dynamic testing includes step changes to magnitude, phase and frequency as well as signals modulated on the power (60 Hz) waveform. These tests characterize speed of response, reproduction of measured values, and rejection of interference. All these effects have an analogy in the actual power system, so the results can be reasonably applied. Developing methods simplify the generation of test signals and analysis of results. A goal is to test for all measurement aspects that may create a problem and correct these before deployment. In addition, determining characteristics that can be used to adjust all measurements to the same basis will enable the performance of precision analysis regardless of the make or model of PMUs that are making the measurements.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-6
PMU Testing and Installation Considerations at the Bonneville Power Administration
BPA has a real-time phasor measurement system with more than 22 PMUs installed in substations feeding data to a control center. To assure the quality and accuracy of the measurement, BPA has developed an extensive test plan for PMUs. From simple beginnings of basic tests, these procedures have continually evolved with both the variety of PMU equipment and applications for which the data was used. Current test methods under development are aimed for more comprehensive characterization of PMU measurement and test process simplification. Basic test procedures assure steady state accuracy of magnitude, phase, and frequency measurement. Dynamic testing includes step changes to magnitude, phase and frequency as well as signals modulated on the power (60 Hz) waveform. These tests characterize speed of response, reproduction of measured values, and rejection of interference. All these effects have an analogy in the actual power system, so the results can be reasonably applied. Developing methods simplify the generation of test signals and analysis of results. A goal is to test for all measurement aspects that may create a problem and correct these before deployment. In addition, determining characteristics that can be used to adjust all measurements to the same basis will enable the performance of precision analysis regardless of the make or model of PMUs that are making the measurements.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19325517,p. 1-6
Evaluation of PMU Dynamic Performance in Both Lab Environments and under Field Operating Conditions
Capturing system dynamics is one important feature of phasor measurements. To ensure PMU accurately reflect system dynamic behavior, one must evaluate the dynamic performance of a PMU. PMU dynamic performance evaluation includes three aspects: PMU modeling studies, laboratory testing and field evaluation. This paper briefly reviews the general PMU model structure, and then continues on PMU dynamic performance evaluation from actual field measurements. Reasons for field evaluation include: (1) inappropriate field settings of a PMU would generate unexpected phasor measurements; and (2) many conditions can not be easily produced in a lab environment. PMU field evaluation includes aspects like time synchronization, timing inconsistency due to filtering, frequency calculation issues, parasitic oscillations/processing artifacts, etc. Actual WECC measurement examples will be presented. Dynamic PMU testing in a lab environment is explored with a special focus on PMU filtering characteristics. How the phasor quality would impact derived system dynamic characteristics is addressed in the later part of this paper.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19325517,p. 1-6
Evaluation of PMU Dynamic Performance in Both Lab Environments and under Field Operating Conditions
Capturing system dynamics is one important feature of phasor measurements. To ensure PMU accurately reflect system dynamic behavior, one must evaluate the dynamic performance of a PMU. PMU dynamic performance evaluation includes three aspects: PMU modeling studies, laboratory testing and field evaluation. This paper briefly reviews the general PMU model structure, and then continues on PMU dynamic performance evaluation from actual field measurements. Reasons for field evaluation include: (1) inappropriate field settings of a PMU would generate unexpected phasor measurements; and (2) many conditions can not be easily produced in a lab environment. PMU field evaluation includes aspects like time synchronization, timing inconsistency due to filtering, frequency calculation issues, parasitic oscillations/processing artifacts, etc. Actual WECC measurement examples will be presented. Dynamic PMU testing in a lab environment is explored with a special focus on PMU filtering characteristics. How the phasor quality would impact derived system dynamic characteristics is addressed in the later part of this paper.