CCCheolhee Cho

Cheolhee Cho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cheolhee Cho has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design Methodology for a Backrest-Lifting Nursing Bed Based on Dual-Channel Behavior–Emotion Data Fusion and Biomechanical Simulation: A Human-Centered and Data-Driven Optimization Approach

    by Xiaochan Wang, Cheolhee Cho, Peng Zhang, Shuyuan Ge, Liyun Wang

    Population aging and rising rehabilitation demands highlight the need for advanced assistive devices to improve mobility in individuals with motor impairments. Existing back-support lifting nursing beds often lack adequate human–machine adaptability, safety, and emotional consideration. This study presents a human-centered, data-driven optimization pipeline that integrates behavior–emotion dual recognition, simulation verification, and parameter optimization with user demand mining, biomechanical simulation, and sustainable practices. The design utilizes GreenAI, focusing on low-power algorithms and eco-friendly materials, ensuring energy-efficient AI models and reducing the environmental footprint. A dual-channel data fusion method was developed, combining movement parameters from sit-to-lie transitions with emotional needs extracted from e-commerce reviews using the Term Frequency-Inverse Document Frequency (TF-IDF) and Latent Dirichlet Allocation (LDA) models. The fuzzy Kano model prioritized design objectives, identifying multi-position adjustment, joint protection, armrest optimization, and interaction comfort as key targets. An AnyBody-based human–device model quantified muscle (erector spinae, rectus abdominis, trapezius) and hip joint loads during posture changes. Simulations verified the design’s ability to improve load distribution, reduce joint stress, and enhance comfort. The optimized nursing bed demonstrated improved adaptability across user profiles while maintaining functional reliability. This framework offers a scalable paradigm for intelligent rehabilitation equipment design, with potential extension toward AI-driven adaptive control and clinical validation. This sustainable methodology ensures that the device not only meets rehabilitation goals but also contributes to a more environmentally responsible healthcare solution, aligning with global sustainability efforts.


  • Open Access

    Medical Imaging-Based Kinematic Modeling for Biomimetic Finger Joints and Hand Exoskeleton Validation

    by Xiaochan Wang, Cheolhee Cho, Peng Zhang, Shuyuan Ge, Jiadi Chen

    Hand rehabilitation exoskeletons play a critical role in restoring motor function in patients with stroke or hand injuries. However, most existing designs rely on fixed-axis assumptions, neglecting the rolling–sliding coupling of finger joints that causes instantaneous center of rotation (ICOR) drift, leading to kinematic misalignment and localized pressure concentrations. This study proposes the Instant Radius Method (IRM) based on medical imaging to continuously model ICOR trajectories of the MCP, PIP, and DIP joints, followed by the construction of an equivalent ICOR through curve fitting. Crossing-type biomimetic kinematic pairs were designed according to the equivalent ICOR and integrated into a three-loop ten-linkage exoskeleton capable of dual DOFs per finger (flexion–extension and abduction–adduction, 10 DOFs in total). Kinematic validation was performed using IMU sensors (Delsys) to capture joint angles, and interface pressure distribution at MCP and PIP was measured using thin-film pressure sensors. Experimental results demonstrated that with biomimetic kinematic pairs, the exoskeleton’s fingertip trajectories matched physiological trajectories more closely, with significantly reduced RMSE. Pressure measurements showed a reduction of approximately 15–25% in mean pressure and 20–30% in peak pressure at MCP and PIP, with more uniform distributions. The integrated framework of IRM-based modeling–equivalent ICOR–biomimetic kinematic pairs–multi-DOF exoskeleton design effectively enhanced kinematic alignment and human–machine compatibility. This work highlights the importance and feasibility of ICOR alignment in rehabilitation robotics and provides a promising pathway toward personalized rehabilitation and clinical translation.