Peng Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peng Zhang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Cheolhee Cho
Department of Design, Kyungpook National University, Daegu 41566, Republic of Korea
1 shared publication - Jiadi Chen
Department of Design, Kyungpook National University, Daegu 41566, Republic of Korea
1 shared publication - Shuyuan Ge
Department of Electrical and Electronic Engineering, Kyungpook National University, Daegu 41566, Republic of Korea
1 shared publication - Xiaochan Wang
Department of Design, Kyungpook National University, Daegu 41566, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 1 October 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (10) , 652
Medical Imaging-Based Kinematic Modeling for Biomimetic Finger Joints and Hand Exoskeleton Validation
Hand rehabilitation exoskeletons play a critical role in restoring motor function in patients with stroke or hand injuries. However, most existing designs rely on fixed-axis assumptions, neglecting the rolling–sliding coupling of finger joints that causes instantaneous center of rotation (ICOR) drift, leading to kinematic misalignment and localized pressure concentrations. This study proposes the Instant Radius Method (IRM) based on medical imaging to continuously model ICOR trajectories of the MCP, PIP, and DIP joints, followed by the construction of an equivalent ICOR through curve fitting. Crossing-type biomimetic kinematic pairs were designed according to the equivalent ICOR and integrated into a three-loop ten-linkage exoskeleton capable of dual DOFs per finger (flexion–extension and abduction–adduction, 10 DOFs in total). Kinematic validation was performed using IMU sensors (Delsys) to capture joint angles, and interface pressure distribution at MCP and PIP was measured using thin-film pressure sensors. Experimental results demonstrated that with biomimetic kinematic pairs, the exoskeleton’s fingertip trajectories matched physiological trajectories more closely, with significantly reduced RMSE. Pressure measurements showed a reduction of approximately 15–25% in mean pressure and 20–30% in peak pressure at MCP and PIP, with more uniform distributions. The integrated framework of IRM-based modeling–equivalent ICOR–biomimetic kinematic pairs–multi-DOF exoskeleton design effectively enhanced kinematic alignment and human–machine compatibility. This work highlights the importance and feasibility of ICOR alignment in rehabilitation robotics and provides a promising pathway toward personalized rehabilitation and clinical translation.
- 1 October 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (10) , 652
Open AccessMedical Imaging-Based Kinematic Modeling for Biomimetic Finger Joints and Hand Exoskeleton Validation
Hand rehabilitation exoskeletons play a critical role in restoring motor function in patients with stroke or hand injuries. However, most existing designs rely on fixed-axis assumptions, neglecting the rolling–sliding coupling of finger joints that causes instantaneous center of rotation (ICOR) drift, leading to kinematic misalignment and localized pressure concentrations. This study proposes the Instant Radius Method (IRM) based on medical imaging to continuously model ICOR trajectories of the MCP, PIP, and DIP joints, followed by the construction of an equivalent ICOR through curve fitting. Crossing-type biomimetic kinematic pairs were designed according to the equivalent ICOR and integrated into a three-loop ten-linkage exoskeleton capable of dual DOFs per finger (flexion–extension and abduction–adduction, 10 DOFs in total). Kinematic validation was performed using IMU sensors (Delsys) to capture joint angles, and interface pressure distribution at MCP and PIP was measured using thin-film pressure sensors. Experimental results demonstrated that with biomimetic kinematic pairs, the exoskeleton’s fingertip trajectories matched physiological trajectories more closely, with significantly reduced RMSE. Pressure measurements showed a reduction of approximately 15–25% in mean pressure and 20–30% in peak pressure at MCP and PIP, with more uniform distributions. The integrated framework of IRM-based modeling–equivalent ICOR–biomimetic kinematic pairs–multi-DOF exoskeleton design effectively enhanced kinematic alignment and human–machine compatibility. This work highlights the importance and feasibility of ICOR alignment in rehabilitation robotics and provides a promising pathway toward personalized rehabilitation and clinical translation.