Aleksander L. Skrede
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aleksander L. Skrede has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Fagerhaug Dalen
Department of Research and Innovation, Møre and Romsdal Hospital Trust, Ålesund, Norway
6 shared publications - Martin Greger Gregersen
Department of Physical Medicine and Rehabilitation, Østfold Hospital Trust, Grålum, Norway
4 shared publications Fredrik A. Nilsen
Department of Orthopaedic Surgery, Østfold Hospital Trust, Grålum, Norway
3 shared publicationsMarius Molund
Department of Orthopaedic Surgery, Østfold Hospital Trust, Grålum, Norway
3 shared publications- Øystein Bjelland
Department of ICT and Natural Sciences, Norwegian University of Science and Technology, Ålesund, Norway
3 shared publications - Alf Inge Hellevik
Department of Research and Innovation, lesund Hospital Trust, lesund, Norway
2 shared publications
Latest Publications
- Open Access
- 10 June 2026
- Published by SAGE Publications in Foot & Ankle International
- Vol. 47 (7) , 906-917
Multiplanar Stability After Syndesmotic Screw Fixation vs Deltoid Ligament Repair in a Cadaveric Weber B/SER4b Ankle Fracture Model With Fibular Plate Fixation
Background: Weber B / Lauge-Hansen supination-external rotation 4b (SER4b) ankle fractures are unstable injuries characterized by complete deltoid ligament ruptures. Biomechanical studies suggest that fibular plate fixation alone is insufficient for SER4b fractures. Concurrent deltoid ligament repair seems necessary. This study explores how syndesmotic fixation, which is a simpler surgical approach, restores stability compared to deltoid repair or combined. Methods: Eight fresh frozen human cadaveric ankle specimens were tested sequentially by a robot in all 5 states: native, SER4b injury model with anatomic fibular plate fixation only, or reinforced with a syndesmotic screw and/or deltoid ligament repair. Stability was measured in lateral translation (talar shift), valgus, and internal and external rotation during a constant 45-N axial load. The primary outcome was talar shift on fluoroscopic images. The minimal clinically important difference (MCID) was predefined as 1.0 mm. Results: Combined plate and syndesmotic screw fixation restored lateral translation stability. The mean difference in talar shift was −0.2 mm compared with native (95% CI −0.8 to 0.5, P = .57). However, talar valgus tilt increased by 18.1° (95% CI 16.1-20.0, P < .001) and external rotation by 15.9° (95% CI 12.6-19.2, P < .001). For combined plate fixation and deltoid ligament repair vs native, the mean difference in talar shift was 0.3 mm (95% CI −0.4 to 1.0), P = .37), also below the pre-defined MCID. Mean valgus and external rotation deviated less from native but were still significantly different, the respective mean differences were 2.7° (95% CI 0.8-4.7, P = .006) and 5.2° (95% CI 1.9-8.5, P = .002). Conclusion: In this cadaveric SER4b injury model, both syndesmotic screw fixation and deltoid ligament repair restore lateral translational stability, when combined with fibular plate fixation. However, only deltoid ligament repair—addressing both the deep posterior and anterior deltoid components—substantially restored rotational and valgus stability, suggesting it provides more comprehensive joint stabilization than syndesmotic screw fixation alone. Clinical Relevance: Syndesmotic screw fixation restores lateral translational stability as well as deltoid ligament repair when both are combined with lateral plate fixation. Complete deltoid ligament repair is superior to the syndesmotic screw in restoring overall stability in cadaveric SER4b ankle fracture models. Given their potential clinical relevance, these findings may be considered in future clinical studies and choice of treatment.
- 10 June 2026
- Published by SAGE Publications in Foot & Ankle International
- Vol. 47 (7) , 906-917
Open AccessMultiplanar Stability After Syndesmotic Screw Fixation vs Deltoid Ligament Repair in a Cadaveric Weber B/SER4b Ankle Fracture Model With Fibular Plate Fixation
Background: Weber B / Lauge-Hansen supination-external rotation 4b (SER4b) ankle fractures are unstable injuries characterized by complete deltoid ligament ruptures. Biomechanical studies suggest that fibular plate fixation alone is insufficient for SER4b fractures. Concurrent deltoid ligament repair seems necessary. This study explores how syndesmotic fixation, which is a simpler surgical approach, restores stability compared to deltoid repair or combined. Methods: Eight fresh frozen human cadaveric ankle specimens were tested sequentially by a robot in all 5 states: native, SER4b injury model with anatomic fibular plate fixation only, or reinforced with a syndesmotic screw and/or deltoid ligament repair. Stability was measured in lateral translation (talar shift), valgus, and internal and external rotation during a constant 45-N axial load. The primary outcome was talar shift on fluoroscopic images. The minimal clinically important difference (MCID) was predefined as 1.0 mm. Results: Combined plate and syndesmotic screw fixation restored lateral translation stability. The mean difference in talar shift was −0.2 mm compared with native (95% CI −0.8 to 0.5, P = .57). However, talar valgus tilt increased by 18.1° (95% CI 16.1-20.0, P < .001) and external rotation by 15.9° (95% CI 12.6-19.2, P < .001). For combined plate fixation and deltoid ligament repair vs native, the mean difference in talar shift was 0.3 mm (95% CI −0.4 to 1.0), P = .37), also below the pre-defined MCID. Mean valgus and external rotation deviated less from native but were still significantly different, the respective mean differences were 2.7° (95% CI 0.8-4.7, P = .006) and 5.2° (95% CI 1.9-8.5, P = .002). Conclusion: In this cadaveric SER4b injury model, both syndesmotic screw fixation and deltoid ligament repair restore lateral translational stability, when combined with fibular plate fixation. However, only deltoid ligament repair—addressing both the deep posterior and anterior deltoid components—substantially restored rotational and valgus stability, suggesting it provides more comprehensive joint stabilization than syndesmotic screw fixation alone. Clinical Relevance: Syndesmotic screw fixation restores lateral translational stability as well as deltoid ligament repair when both are combined with lateral plate fixation. Complete deltoid ligament repair is superior to the syndesmotic screw in restoring overall stability in cadaveric SER4b ankle fracture models. Given their potential clinical relevance, these findings may be considered in future clinical studies and choice of treatment.
- Open Access
- 21 June 2025
- Published by SAGE Publications in Foot & Ankle International
- Vol. 46 (7) , 688-696
Effects of Fibular Plate Fixation and Deep Posterior Tibiotalar Ligament Repair on Ankle Stability in a Weber B Fracture Model with Complete Deltoid Ligament Sectioning
Background: Weber B (supination external rotation) ankle fractures with complete deltoid ligament rupture (SER4b) are typically considered unstable and treated with plate fixation of the fibula. Recent studies have suggested a significant ankle-stabilizing role of the deep posterior tibiotalar ligament (dPTTL), which questions current practice. To our knowledge, there are few studies on the biomechanical effects of plate fixation and none on dPTTL repair. Therefore, this study aims to evaluate the effects of fibular plate fixation and dPTTL repair on ankle stability in a Weber B fracture model with complete deltoid ligament sectioning. Methods: We robotically tested 15 cadaveric ankle specimens in 5 states: native joint, SER4b injury models, SER4b injury models with plate fixation of the fibula, SER4b injury models with dPTTL repair, and SER4b injury models with combined plate fixation and dPTTL repair. The robot measured ankle stability in lateral translation, valgus, and internal and external rotation. Talar shift and talar tilt were measured on mortise view radiographs. The primary outcome was differences in talar shift in neutral ankle position. Results: When comparing SER4b injury models with plate fixation to native ankles, we found a mean difference in talar shift of 1.18 mm (95% CI 0.88-1.48, P ≤ .001), talar tilt of 14.47 degrees (95% CI 12.90-16.05, P ≤ .001), and external rotation of 11.44 degrees (95% CI 9.00-13.87, P ≤ .001). When comparing SER4b injury models with combined plate fixation and dPTTL repair to native ankles, we found a mean difference in talar shift of 0.23 mm (95% CI −0.07 to 0.54, P = .132), talar tilt of 1.65 degrees (95% CI 0.07-3.22, P = .040), and external rotation of 5.26 degrees (95% CI 2.82-7.70, P ≤ .001). Conclusion: This study's main finding was that plate fixation of the fibula alone did not considerably enhance ankle stability in SER4b injury models. However, ankle stability was substantially improved when plate fixation and dPTTL repair were combined. Clinical Relevance: Our study showed that dPTTL repair, in addition to plate fixation, improved ankle stability in Weber B SER4b fracture models. This information should be considered in future clinical research and treatment strategies for these fractures.
- 21 June 2025
- Published by SAGE Publications in Foot & Ankle International
- Vol. 46 (7) , 688-696
Open AccessEffects of Fibular Plate Fixation and Deep Posterior Tibiotalar Ligament Repair on Ankle Stability in a Weber B Fracture Model with Complete Deltoid Ligament Sectioning
Background: Weber B (supination external rotation) ankle fractures with complete deltoid ligament rupture (SER4b) are typically considered unstable and treated with plate fixation of the fibula. Recent studies have suggested a significant ankle-stabilizing role of the deep posterior tibiotalar ligament (dPTTL), which questions current practice. To our knowledge, there are few studies on the biomechanical effects of plate fixation and none on dPTTL repair. Therefore, this study aims to evaluate the effects of fibular plate fixation and dPTTL repair on ankle stability in a Weber B fracture model with complete deltoid ligament sectioning. Methods: We robotically tested 15 cadaveric ankle specimens in 5 states: native joint, SER4b injury models, SER4b injury models with plate fixation of the fibula, SER4b injury models with dPTTL repair, and SER4b injury models with combined plate fixation and dPTTL repair. The robot measured ankle stability in lateral translation, valgus, and internal and external rotation. Talar shift and talar tilt were measured on mortise view radiographs. The primary outcome was differences in talar shift in neutral ankle position. Results: When comparing SER4b injury models with plate fixation to native ankles, we found a mean difference in talar shift of 1.18 mm (95% CI 0.88-1.48, P ≤ .001), talar tilt of 14.47 degrees (95% CI 12.90-16.05, P ≤ .001), and external rotation of 11.44 degrees (95% CI 9.00-13.87, P ≤ .001). When comparing SER4b injury models with combined plate fixation and dPTTL repair to native ankles, we found a mean difference in talar shift of 0.23 mm (95% CI −0.07 to 0.54, P = .132), talar tilt of 1.65 degrees (95% CI 0.07-3.22, P = .040), and external rotation of 5.26 degrees (95% CI 2.82-7.70, P ≤ .001). Conclusion: This study's main finding was that plate fixation of the fibula alone did not considerably enhance ankle stability in SER4b injury models. However, ankle stability was substantially improved when plate fixation and dPTTL repair were combined. Clinical Relevance: Our study showed that dPTTL repair, in addition to plate fixation, improved ankle stability in Weber B SER4b fracture models. This information should be considered in future clinical research and treatment strategies for these fractures.
- Open Access
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 21723-21733
Toward Generality of a Framework for Quantifying Biomechanical Stability: Demonstration on the Ankle
This paper presents a mathematical description and experimental investigation of using an industrial robot to evaluate biomechanical stability in human cadaveric ankle specimens. We have previously proposed a methodology and parameterizable task space motion framework for biomechanical investigations of shoulders. The present study aimed to demonstrate the generality and use of our framework to replicate an ankle test protocol from the literature, and to experimentally evaluate the replicated test protocol. Stability tests in cadaveric studies can be performed by applying a known force or torque to the joint, and then measure the resulting linear or angular displacement. The relative stability between joint states can be determined by comparing the magnitude of motion, for example between the intact, injured, or surgically repaired joints. Increased joint motion between states can be interpreted as decreased stability, and decreased joint motion can be interpreted as increased stability. Comparing the motion between different states can be used to investigate the effects of soft tissue or bony structures on stability. The replicated protocol was tested in a technical pilot study using a fresh frozen human cadaveric ankle specimen. The specimen was tested in the intact state and in three subsequent injury states. However, this pilot study showed that the framework could successfully be parameterized to conduct tests on the ankle joint. The expected trend for subsequent injury states was progressive instability, and the observed trends from experimental testing aligned with this prior expectation. Additional work on the framework is necessary for it to be truly generalized.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 21723-21733
Open AccessToward Generality of a Framework for Quantifying Biomechanical Stability: Demonstration on the Ankle
This paper presents a mathematical description and experimental investigation of using an industrial robot to evaluate biomechanical stability in human cadaveric ankle specimens. We have previously proposed a methodology and parameterizable task space motion framework for biomechanical investigations of shoulders. The present study aimed to demonstrate the generality and use of our framework to replicate an ankle test protocol from the literature, and to experimentally evaluate the replicated test protocol. Stability tests in cadaveric studies can be performed by applying a known force or torque to the joint, and then measure the resulting linear or angular displacement. The relative stability between joint states can be determined by comparing the magnitude of motion, for example between the intact, injured, or surgically repaired joints. Increased joint motion between states can be interpreted as decreased stability, and decreased joint motion can be interpreted as increased stability. Comparing the motion between different states can be used to investigate the effects of soft tissue or bony structures on stability. The replicated protocol was tested in a technical pilot study using a fresh frozen human cadaveric ankle specimen. The specimen was tested in the intact state and in three subsequent injury states. However, this pilot study showed that the framework could successfully be parameterized to conduct tests on the ankle joint. The expected trend for subsequent injury states was progressive instability, and the observed trends from experimental testing aligned with this prior expectation. Additional work on the framework is necessary for it to be truly generalized.
- Open Access
- 19 March 2024
- Published by SAGE Publications in Foot & Ankle International
- Vol. 45 (6) , 641-647
Effects of Fibular Plate Fixation on Ankle Stability in a Weber B Fracture Model With Partial Deltoid Ligament Sectioning
Background: Weber B fractures with concomitant deltoid ligament injury have traditionally been operated with open reduction and internal fixation of the fibular fracture. More recently, clinical studies have suggested that some fractures have concomitant partial deltoid ligament injury with the deep posterior tibiotalar ligament intact (SER4a), allowing for nonoperative treatment in this subgroup. This study explores whether plate fixation of the fibula improves ankle stability in an SER4a injury model. And if so, does it restore native ankle stability? Methods: Fifteen cadaver ankle specimens were tested in 3 states using an industrial robot: intact joint, SER4a models without plate fixation of the fibula, and SER4a models with plate fixation of the fibula. The robot measured ankle stability in lateral translation, valgus, and internal and external rotation in 3 talocrural joint positions: 10 degrees dorsiflexion, neutral, and 20 degrees plantar flexion. Furthermore, fluoroscopic mortise view radiographs were taken to measure isolated talar shift and talar tilt. Results: The talar shift and tilt tests showed no differences between the SER4a injury model with and without fibular plate fixation at neutral ankle position with a mean difference of −0.16 mm (95% CI −0.33 to 0.01 mm, P = .071) for talar shift and −0.15 degrees (95% CI −0.01 to 0.30 degrees, P = .068) for talar tilt. However, plate fixation increased external rotation stability, with mean improvements ranging from −7.43 to −9.52 degrees ( P < .001 for all comparisons), but did not restore intact ankle stability. For internal rotation, plate fixation resulted in minor differences. Conclusion: The results of this suggest that plate fixation of the fibular fracture primarily improves external rotation stability but does not substantially improve lateral translation, valgus, or internal rotation stability in SER4a injury models. In this robotic cadaver model, fibular plate fixation did not fully restore intact ankle stability after simulated SER4a injury. Clinical Relevance: This study offers insights into the effects of fibular plate fixation on Weber B/SER4a injury models and may assist informed decisions when selecting treatments for these types of fractures.
- 19 March 2024
- Published by SAGE Publications in Foot & Ankle International
- Vol. 45 (6) , 641-647
Open AccessEffects of Fibular Plate Fixation on Ankle Stability in a Weber B Fracture Model With Partial Deltoid Ligament Sectioning
Background: Weber B fractures with concomitant deltoid ligament injury have traditionally been operated with open reduction and internal fixation of the fibular fracture. More recently, clinical studies have suggested that some fractures have concomitant partial deltoid ligament injury with the deep posterior tibiotalar ligament intact (SER4a), allowing for nonoperative treatment in this subgroup. This study explores whether plate fixation of the fibula improves ankle stability in an SER4a injury model. And if so, does it restore native ankle stability? Methods: Fifteen cadaver ankle specimens were tested in 3 states using an industrial robot: intact joint, SER4a models without plate fixation of the fibula, and SER4a models with plate fixation of the fibula. The robot measured ankle stability in lateral translation, valgus, and internal and external rotation in 3 talocrural joint positions: 10 degrees dorsiflexion, neutral, and 20 degrees plantar flexion. Furthermore, fluoroscopic mortise view radiographs were taken to measure isolated talar shift and talar tilt. Results: The talar shift and tilt tests showed no differences between the SER4a injury model with and without fibular plate fixation at neutral ankle position with a mean difference of −0.16 mm (95% CI −0.33 to 0.01 mm, P = .071) for talar shift and −0.15 degrees (95% CI −0.01 to 0.30 degrees, P = .068) for talar tilt. However, plate fixation increased external rotation stability, with mean improvements ranging from −7.43 to −9.52 degrees ( P < .001 for all comparisons), but did not restore intact ankle stability. For internal rotation, plate fixation resulted in minor differences. Conclusion: The results of this suggest that plate fixation of the fibular fracture primarily improves external rotation stability but does not substantially improve lateral translation, valgus, or internal rotation stability in SER4a injury models. In this robotic cadaver model, fibular plate fixation did not fully restore intact ankle stability after simulated SER4a injury. Clinical Relevance: This study offers insights into the effects of fibular plate fixation on Weber B/SER4a injury models and may assist informed decisions when selecting treatments for these types of fractures.
- Open Access
- 21 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 29397-29413
Quantifying Passive Biomechanical Stability Using an Industrial Robot: Development and Experimental Validation of a Task Space Motion Framework
This paper presents a methodology and generalized motion framework for quantifying passive biomechanical stability and Range of Motion of human cadaveric specimens, using a position-controlled industrial robot and a wrist-mounted force/torque sensor. Many biomechanical studies on diarthrodial joints using human cadaveric specimens are published in the literature, using various test protocols and machines to apply the loading conditions. In these studies, laxity or mobility of the joints are quantified by measuring the magnitude of translations and rotations with respect to force and torque. The protocols and anatomical motions of the specimens are usually described high-level, textually, and from a medical perspective to a broad audience. The present paper aims to describe, from a technical perspective to a robotics audience, our method to perform biomechanical studies and how existing protocols can be replicated through parameterization using the existing textual descriptions. To accomplish this, we propose a generalized task space motion framework for performing biomechanical studies on diarthrodial joints. The generalization is made by defining the Tool Center Point at the cadaveric joint rotation center and aligning the specimen so the anatomical motions can be modeled in world frame or tool frame. Our framework has the potential to rapidly automate new or existing protocols through parameterization, including protocols performed by machines other than industrial robots or serial manipulators. The framework was evaluated in a technical pilot study on the shoulder, using one cadaveric shoulder specimen and an established protocol. The specimen was tested in the intact state and in an injury state.
- 21 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 29397-29413
Open AccessQuantifying Passive Biomechanical Stability Using an Industrial Robot: Development and Experimental Validation of a Task Space Motion Framework
This paper presents a methodology and generalized motion framework for quantifying passive biomechanical stability and Range of Motion of human cadaveric specimens, using a position-controlled industrial robot and a wrist-mounted force/torque sensor. Many biomechanical studies on diarthrodial joints using human cadaveric specimens are published in the literature, using various test protocols and machines to apply the loading conditions. In these studies, laxity or mobility of the joints are quantified by measuring the magnitude of translations and rotations with respect to force and torque. The protocols and anatomical motions of the specimens are usually described high-level, textually, and from a medical perspective to a broad audience. The present paper aims to describe, from a technical perspective to a robotics audience, our method to perform biomechanical studies and how existing protocols can be replicated through parameterization using the existing textual descriptions. To accomplish this, we propose a generalized task space motion framework for performing biomechanical studies on diarthrodial joints. The generalization is made by defining the Tool Center Point at the cadaveric joint rotation center and aligning the specimen so the anatomical motions can be modeled in world frame or tool frame. Our framework has the potential to rapidly automate new or existing protocols through parameterization, including protocols performed by machines other than industrial robots or serial manipulators. The framework was evaluated in a technical pilot study on the shoulder, using one cadaveric shoulder specimen and an established protocol. The specimen was tested in the intact state and in an injury state.
- Open Access
- 21 July 2023
- Published by SAGE Publications in Foot & Ankle International
- Vol. 44 (9) , 895-904
Effects of Progressive Deltoid Ligament Sectioning on Weber B Ankle Fracture Stability
Background: Conventionally, transsyndesmotic fibula fractures with concomitant signs of deltoid ligament injury have been considered unstable and thus treated operatively. Recent studies have indicated that partial deltoid ligament rupture is common and may allow for nonoperative treatment of stress-unstable ankles if normal tibiotalar alignment is obtained in the weightbearing position. Biomechanical support for this principle is scarce. The purpose of this study was to evaluate the biomechanical effects of gradually increasing deltoid ligament injury in transsyndesmotic fibula fractures. Methods: Fifteen cadaveric ankle specimens were tested using an industrial robot. All specimens were tested in 4 states: native, SER2, SER4a, and SER4b models. Ankle stability was measured in lateral translation, valgus, and internal and external rotation stress in 3 talocrural joint positions: 20 degrees plantarflexion, neutral, and 10 degrees dorsiflexion. Talar shift and talar valgus tilt in the talocrural joint was measured using fluoroscopy. Results: In most tests, SER2 and SER4a models resulted in a small instability increase compared to native joints and thus were deemed stable according to our predefined margins. However, SER4a models were unstable when tested in the plantarflexed position and for external rotation in all positions. In contrast, SER4b models had large-magnitude instability in all directions and all tested positions and were thus deemed unstable. Conclusion: This study demonstrated substantial increases in instability between the SER4a and SER4b states. This controlled cadaveric simulation suggests a significant ankle-stabilizing role of the deep posterior deltoid after oblique transsyndesmotic fibular fracture and transection of the superficial and anterior deep deltoid ligaments. Clinical Relevance: The study provides new insights into how the heterogenicity of deltoid ligament injuries can affect the natural stability of the ankle after Weber B fractures. These findings may be useful in developing more targeted and better treatment strategies.
- 21 July 2023
- Published by SAGE Publications in Foot & Ankle International
- Vol. 44 (9) , 895-904
Open AccessEffects of Progressive Deltoid Ligament Sectioning on Weber B Ankle Fracture Stability
Background: Conventionally, transsyndesmotic fibula fractures with concomitant signs of deltoid ligament injury have been considered unstable and thus treated operatively. Recent studies have indicated that partial deltoid ligament rupture is common and may allow for nonoperative treatment of stress-unstable ankles if normal tibiotalar alignment is obtained in the weightbearing position. Biomechanical support for this principle is scarce. The purpose of this study was to evaluate the biomechanical effects of gradually increasing deltoid ligament injury in transsyndesmotic fibula fractures. Methods: Fifteen cadaveric ankle specimens were tested using an industrial robot. All specimens were tested in 4 states: native, SER2, SER4a, and SER4b models. Ankle stability was measured in lateral translation, valgus, and internal and external rotation stress in 3 talocrural joint positions: 20 degrees plantarflexion, neutral, and 10 degrees dorsiflexion. Talar shift and talar valgus tilt in the talocrural joint was measured using fluoroscopy. Results: In most tests, SER2 and SER4a models resulted in a small instability increase compared to native joints and thus were deemed stable according to our predefined margins. However, SER4a models were unstable when tested in the plantarflexed position and for external rotation in all positions. In contrast, SER4b models had large-magnitude instability in all directions and all tested positions and were thus deemed unstable. Conclusion: This study demonstrated substantial increases in instability between the SER4a and SER4b states. This controlled cadaveric simulation suggests a significant ankle-stabilizing role of the deep posterior deltoid after oblique transsyndesmotic fibular fracture and transection of the superficial and anterior deep deltoid ligaments. Clinical Relevance: The study provides new insights into how the heterogenicity of deltoid ligament injuries can affect the natural stability of the ankle after Weber B fractures. These findings may be useful in developing more targeted and better treatment strategies.